101601-4220 ZEXEL INJECTION-PUMP ASSEMBLY Cross 1016014220 5156003692


 

Information injection-pump assembly

ZEXEL 101601-4220 1016014220
ISUZU 5156003692 5156003692
101601-4220 INJECTION-PUMP ASSEMBLY
Rating:
41
Buy INJECTION-PUMP ASSEMBLY 101601-4220 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
101601-4220 
 
5156003692  ISUZU
INJECTION-PUMP ASSEMBLY
6BB1 *




Information:

Engine Runs Smoothly
Possible Causes/CorrectionsDirty Air Cleaner
If the air cleaner has a restriction indicator, see if the red piston is in view. If there is no restriction indicator, restriction can be checked with a water manometer or a vacuum gauge (which measures in inches of water). Make a connection to the piping between the air cleaner and the inlet of the turbocharger. Check with the engine running at full load rpm. Maximum restriction is 635 mm (25 in) of water. If a gauge is not available, visually check the air cleaner element for dirt. If the element is dirty, clean the element or install a new element.Air Inlet Piping Damage or Restriction
Make a visual inspection of the air inlet system and check for damage to piping, rags in the inlet piping, or damage to the rain cap or the cap pushed too far on the inlet pipe. If no damage is seen, check inlet restriction with a clean air cleaner element.Exhaust System Restriction
Make a visual inspection of the exhaust system. Check for damage to piping or for a bad muffler. If no damage is found, you can check the system by checking the back pressure from the exhaust (pressure difference measurement between exhaust outlet and atmosphere). The back pressure must not be more than 1016 mm (40 in) of water. You can also check by removing the exhaust pipes from the exhaust manifolds. With the exhaust pipes removed, start and load the engine on a chassis dynamometer to see if the problem is corrected.Fuel Injection Timing Not Correct
Check and make necessary adjustments as in Testing and Adjusting section of this Service Manual.Fuel Setting Is Not Correct
Check and make necessary adjustments as in Testing and Adjusting section of this Service Manual. See the Fuel Setting And Related Information Fiche for the correct fuel setting.Low Quality Fuel
Test the engine with fuel according to recommendations by Caterpillar Inc. For more information see Special Instruction, Form No. SEHS7067, Fuel Recommendations For Caterpillar Diesel Engines. Also, Special Instruction, Form No. SEHS6947 has fuel correction factors and tables.Bad Fuel Nozzle(s)
Bad fuel nozzles will normally cause the engine to misfire and run rough, but can cause too much smoke with engine still running smooth. Remove the fuel nozzles and test as in Testing and Adjusting section of this Service Manual.Wrong Seal Washer Installed Under Nozzle(s)
The use of incorrect washers change the location of the fuel injection nozzles in the combustion chamber. This effects smoke. Check the Engine Arrangement for the correct part number to use.Valve Adjustment Not Correct or Valve Leakage
Check and make necessary adjustments as in Testing and Adjusting section of this Service Manual. Intake valve clearance is 0.38 mm (.015 in) and exhaust valve clearance is 0.76 mm (.030 in). Valve leakage normally causes the engine to misfire and run rough.Bad Fuel Injection Pump
An injection pump can have a good fuel flow coming from it but cause rough running because of slow timing that is caused by wear on the bottom end of the

Have questions with 101601-4220?





Group cross 101601-4220 ZEXEL

Isuzu 

 
5156006053 
INJECTION-PUMP ASSEMBLY
6BD1
 
5156006132 
INJECTION-PUMP ASSEMBLY
6BD1
101601-4220  
 
5156003692 
INJECTION-PUMP ASSEMBLY
6BB1
 
5156004464 
INJECTION-PUMP ASSEMBLY
6BB1
 
5156005641 
INJECTION-PUMP ASSEMBLY
6BB1
 
5156004982 
INJECTION-PUMP ASSEMBLY
6BB1
 
5156003820 
INJECTION-PUMP ASSEMBLY
6BB1
 
5156007781 
INJECTION-PUMP ASSEMBLY
6BD1
 
5156007790 
INJECTION-PUMP ASSEMBLY
6BB1
9 400 614 588 
5156004987 
INJECTION-PUMP ASSEMBLY
6BB1