101495-3431 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014953431


 

Information injection-pump assembly

ZEXEL 101495-3431 1014953431
101495-3431 INJECTION-PUMP ASSEMBLY
Rating:
79
Buy INJECTION-PUMP ASSEMBLY 101495-3431 zexel genuine, new aftermarket engine parts with delivery

Service parts 101495-3431 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-8800
3. GOVERNOR 105400-8831
4. SUPPLY PUMP 105220-5610
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-6670
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 19.6(200)
13. NOZZLE-HOLDER 105048-3300
14. NOZZLE 105017-2580
15. NOZZLE SET

Include in #1:

101495-3431 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101495-3431 1014953431


Zexel num
Bosch num
Firm num
Name
101495-3431 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-4-3
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cal 1-3
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   10
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   48.4 47.4 49.4
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   8.6+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   8 7 9
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101495-3431
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK CAP: R1 (4)Idle sub spring setting: L1.
----------
K=16 R1=(17.5)mm L1=6-0.5mm
----------

Speed control lever angle

Test data 101495-3431
F:Full speed I:Idle (1)Set the pump speed at aa. ( At delivery ) (2)Set the pump speed at bb. (3)Stopper bolt setting
----------
aa=900r/min bb=750r/min
----------
a=6deg+-5deg b=22deg+-5deg c=7deg+-5deg

Stop lever angle

Test data 101495-3431
N:Pump normal S:Stop the pump. (1)Pump speed aa and rack position bb (to be sealed at delivery) (2)No return spring
----------
aa=0r/min bb=1-0.5mm
----------
a=27.5deg+-5deg b=(55deg)

Timing setting

Test data 101495-3431
(1)Pump vertical direction (2)Position of key groove at No 1 cylinder's beginning of injection (3)Stamp aligning marks on the pump housing flange. (4)- (5)-
----------

----------
a=58deg+-3deg b=2deg+-30min




Information:


Cat does not warrant the quality or performance of non-Cat fluids.
Do NOT mix brands or types of SCA. Do NOT mix SCAs and extenders.Failure to follow the recommendations can result in shortened cooling system component life.
Use Only Approved SCAs. Conventional coolants require the maintenance addition of SCA throughout their expected life. Do NOT use an SCA with a coolant unless specifically approved by the coolant supplier for use with their coolant. It is the responsibility of the coolant manufacturer to ensure compatibility and acceptable performance.Failure to follow the recommendations can result in shortened cooling system component life.
Follow the maintenance information provided in the “Coolant and General Maintenance Recommendations” section in this Special Publication.Select a commercial diesel engine antifreeze coolant that meets all the requirements given in Table 1. The table contains the requirements for coolant to meet the published service intervals.The provided requirements are applicable to finished coolants and not for the concentrates. When concentrated coolant/antifreeze is mixed, Cat recommends mixing the concentrate with distilled water or with deionized water. If distilled water or deionized water is not available, water which has the required properties may be used. For the water properties, refer to this Special Publication, "General Coolant Information" article.Coolant/antifreezes for heavy-duty applications that meet "ASTM D6210" do not require treatment with SCA at the initial fill. Use the recommended 1:1 or higher concentration with recommended water. Treatment with SCA is required on a maintenance basis.The SCA manufacturer is responsible for ensuring the SCA is compatible with water meeting the “Caterpillar Minimum Acceptable Water Quality Requirements” as found in this Special Publication, and "ASTM D6210-08, Table X1.1". The coolant manufacturer and the SCA manufacturer are responsible to ensure that the products will not cause cooling system harm.Do not mix brands or types of coolants with different brands or types of SCA or extender.If using non Cat coolants, refer to the coolant manufacturer for information on a compatible SCA.Treat the compatible commercial coolant with 3 to 6 percent Cat SCA by volume. Maintain a 3 to 6 percent concentration level of SCA in the cooling system. For more information, refer to this Special Publication, "Conventional Coolant/Antifreeze Cooling System Maintenance" article.
Table 1
Technical Requirements for Commercial Diesel Engine Antifreeze Coolants
Specifications ASTM D6210-08
Additional Requirements Silicon: 100 ppm minimum to 275 ppm maximum
Nitrites: maintained at 1200ppm (70 grains/US gal) minimum to 2400 ppm (140 grains/US gal) maximum
Cat SCA at 3 to 6 percent (if Cat SCA is added)
Maintenance ASTM D6210-08 Add compatible SCA at maintenance intervals
Clean and flush the cooling system at drain intervals

Have questions with 101495-3431?





Group cross 101495-3431 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
101495-3431  
 
 
INJECTION-PUMP ASSEMBLY
9 400 611 162 
 
INJECTION-PUMP ASSEMBLY
9 400 611 320 
 
INJECTION-PUMP ASSEMBLY
4D95L
9 400 612 163 
 
INJECTION-PUMP ASSEMBLY

Komatsu 

9 400 612 655 
6204711150 
INJECTION-PUMP ASSEMBLY
4D95L
Back to top