Information injection-pump assembly
ZEXEL
101495-3330
1014953330

Rating:
Service parts 101495-3330 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
6206-11-3100
12.
Open Pre:MPa(Kqf/cm2)
19.6{200}
15.
NOZZLE SET
Cross reference number
ZEXEL
101495-3330
1014953330
Zexel num
Bosch num
Firm num
Name
101495-3330
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
11.3
Pump speed
r/min
950
950
950
Average injection quantity
mm3/st.
41
40
42
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
9.6+-0.5
Pump speed
r/min
495
495
495
Average injection quantity
mm3/st.
10.5
9.5
11.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT: RAL
----------
K=12 RAL=15+0.2mm
----------
----------
K=12 RAL=15+0.2mm
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=3deg+-5deg b=21deg+-5deg
----------
----------
a=3deg+-5deg b=21deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
(1)Rack position = aa, speed = bb (stamp at delivery)
(2)No return spring
----------
aa=1-0.2mm bb=0r/min
----------
a=27.5deg+-5deg b=(55deg)
----------
aa=1-0.2mm bb=0r/min
----------
a=27.5deg+-5deg b=(55deg)
Timing setting

(1)Pump vertical direction
(2)Position of key groove at No 1 cylinder's beginning of injection
(3)Stamp aligning marks on the pump housing flange.
(4)-
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The DOC/DPF can become plugged if an NRS cooler failure occurs and coolant passes out the exhaust. Solution
If an engine has an NRS cooler failure, the DPF and DOC will need inspected for calcium deposits. In some cases calcium has partially filled the DPF and caused frequent regeneration issues, and erratic high soot loading readings.
Illustration 1 g03374496
Example of calcium deposits on DPF face
Illustration 2 g03374497
Example of calcium deposits on DPF faceThe calcium deposits will be a white and black powdery mixture on the face of the DPF and the DOC. Refer to Illustrations 1 and 2 for examples of a DPF with calcium plugging on the DPF face.Refer to Reuse And Salvage Guidelines, SEBF9223, "Inspection of Diesel Particulate Filters and Diesel Oxidation Catalysts for Tier 4 Machine and Industrial Engines" for further assistance.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The DOC/DPF can become plugged if an NRS cooler failure occurs and coolant passes out the exhaust. Solution
If an engine has an NRS cooler failure, the DPF and DOC will need inspected for calcium deposits. In some cases calcium has partially filled the DPF and caused frequent regeneration issues, and erratic high soot loading readings.
Illustration 1 g03374496
Example of calcium deposits on DPF face
Illustration 2 g03374497
Example of calcium deposits on DPF faceThe calcium deposits will be a white and black powdery mixture on the face of the DPF and the DOC. Refer to Illustrations 1 and 2 for examples of a DPF with calcium plugging on the DPF face.Refer to Reuse And Salvage Guidelines, SEBF9223, "Inspection of Diesel Particulate Filters and Diesel Oxidation Catalysts for Tier 4 Machine and Industrial Engines" for further assistance.
Have questions with 101495-3330?
Group cross 101495-3330 ZEXEL
Komatsu
Komatsu
101495-3330
INJECTION-PUMP ASSEMBLY