Information injection-pump assembly
BOSCH
9 400 613 362
9400613362
ZEXEL
101495-3262
1014953262
KOMATSU
6202731160
6202731160

Rating:
Service parts 101495-3262 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
6202-13-3500
12.
Open Pre:MPa(Kqf/cm2)
22.1{225}
15.
NOZZLE SET
Include in #1:
101495-3262
as INJECTION-PUMP ASSEMBLY
Include in #2:
104741-7420
as _
Cross reference number
BOSCH
9 400 613 362
9400613362
ZEXEL
101495-3262
1014953262
KOMATSU
6202731160
6202731160
Zexel num
Bosch num
Firm num
Name
101495-3262
9 400 613 362
6202731160 KOMATSU
INJECTION-PUMP ASSEMBLY
4D95S K
4D95S K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
9.9
Pump speed
r/min
1225
1225
1225
Average injection quantity
mm3/st.
29.6
28.6
30.6
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
9.2+-0.5
Pump speed
r/min
410
410
410
Average injection quantity
mm3/st.
8
7
9
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT: RAL
(4)Rack difference between N = N1 and N = N2
(5)Rack difference to N = N3
----------
K=12 RAL=15+0.2mm N1=1225r/min N2=700r/min N3=1225r/min
----------
----------
K=12 RAL=15+0.2mm N1=1225r/min N2=700r/min N3=1225r/min
----------
Speed control lever angle

F:Full speed
I:Idle
S:Stop
----------
----------
a=8deg+-5deg b=32deg+-3deg c=28deg+-5deg
----------
----------
a=8deg+-5deg b=32deg+-3deg c=28deg+-5deg
Timing setting

(1)Pump vertical direction
(2)Position of key groove at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(60deg)
----------
----------
a=(60deg)
Information:
Table 2
Specifications for Valve Opening Pressure
Nozzle Assembly Valve Opening Pressure
1W-5829
10300 to 17690 kPa (1500 to 2505 psi)
4W-1819
4W-8483
7E-3969
7N-0449
7W-3710
7W-8043
9N-3979
101-0060
115-3354
122-9007
9L-7883
16560 to 17990 kPa (2400 to 2600 psi)
9L-9263
9N-2366
9L-6969
13090 to 19900 kPa (1900 2900 psi)
9N-3299
9N-3700 If the fuel nozzle is not within specifications, stop the test and do not use the nozzle.Check for Tip Leakage
Close the gauge protector valve (0 to 40,000 kPa (0 to 5,800 psi) gauge).
Flush the fuel nozzle that is being tested by pumping the tester for 3 full strokes.
Open the gauge protector valve (0 to 40,000 kPa (0 to 5,800 psi) gauge).
Use a clean cloth to dry the tip and the body of the fuel injector. All test fluid should be wiped from the nozzle assembly.
A clean cloth should be wrapped around the top of the fuel nozzle in order to absorb any internal return leakage.
Calculate the test pressure that will be used for the tip leakage test.Use the fuel nozzle's valve opening pressure, that has been previously recorded, in order to calculate the test pressure for the nozzle that is being tested.
Subtract a value of 1875 kPa (275 psi) from the valve opening pressure that was previously obtained.
Record the result of the calculation as the test pressure that will be used for the tip leakage test.
Slowly apply the test pressure, that has been calculated in Step 6, to the fuel nozzle.
Close the pump isolator valve.
Hold this test pressure for 10 seconds.
Count the number of drops of test fluid that drips from the nozzle during the duration of the test. Open the pump isolator valve in order to release the pressure on the fuel nozzle when the test is completed.Refer to the information that is provided in Table 3 in order to evaluate the results of the test.Note: Ensure that any test fluid that collects on the tip of the fuel nozzle is not fluid leakage from the test fixture.
Table 3
Specifications for Tip Leakage
(Leakage within 15 seconds after the test pressure is applied to the nozzle.)
Nozzle Assembly Maximum Leakage
1W-5829 20 drops (1)
4W-1819
4W-8483
7E-3969
7N-0449
7W-3710
7W-8043
9N-3979
101-0060
115-3354
122-9007
9L-7883 3 drops (1)
9L-9263
9N-2366
9L-6969 30 drops (1)
9N-3299
9N-3700
( 1 ) No minimum specificationIf the tip leakage for the fuel nozzle is not within specifications, stop the test and do not use the fuel nozzle.Test the Fuel Nozzle for Plugged Orifices
Illustration 2 g00923165
Spray patterns for pencil type fuel nozzles.
Close the gauge protector valve (0 to 40,000 kPa (0 to 5,800 psi) gauge).
Rapidly increase the pressure on the fuel nozzle until fluid sprays from the tip of the fuel nozzle.Note: For this test, each full
Have questions with 101495-3262?
Group cross 101495-3262 ZEXEL
Komatsu
Komatsu
Komatsu
Komatsu
Komatsu
101495-3262
9 400 613 362
6202731160
INJECTION-PUMP ASSEMBLY
4D95S
4D95S