101495-3150 ZEXEL 9 400 614 515 BOSCH INJECTION-PUMP ASSEMBLY 9400614515 1014953150 6202731181


 

Information injection-pump assembly

BOSCH 9 400 614 515 9400614515
ZEXEL 101495-3150 1014953150
KOMATSU 6202731181 6202731181
101495-3150 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 101495-3150 zexel genuine, new aftermarket engine parts with delivery

Service parts 101495-3150 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-8760
3. GOVERNOR 105400-7190
4. SUPPLY PUMP 105220-5890
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4850
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 22.1{225}
13. NOZZLE-HOLDER 105048-3300
14. NOZZLE 105017-0840
15. NOZZLE SET

Include in #1:

101495-3150 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 614 515 9400614515
ZEXEL 101495-3150 1014953150
KOMATSU 6202731181 6202731181


Zexel num
Bosch num
Firm num
Name
101495-3150 
9 400 614 515 
6202731181  KOMATSU
INJECTION-PUMP ASSEMBLY
4D95S * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-2-4-3
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cyl.1-2
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cal 1-3
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   9.8
Pump speed r/min   1225 1225 1225
Average injection quantity mm3/st.   30.5 29.5 31.5
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.7+-0. 5
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   33 31 35
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   -
Rack position   9.2+-0.5
Pump speed r/min   410 410 410
Average injection quantity mm3/st.   8 7 9
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101495-3150
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)RACK LIMIT: RAL (3)Rack difference from N = N1 (4)Rack difference to N = N2
----------
K=8 RAL=15+0.2mm N1=1225r/min N2=1225r/min
----------

Speed control lever angle

Test data 101495-3150
F:Full speed I:Idle S:Stop
----------

----------
a=(5deg)+-5deg b=(27deg)+-5deg c=32deg+-3deg

Timing setting

Test data 101495-3150
(1)Pump vertical direction (2)Position of key groove at No 1 cylinder's beginning of injection (3)Stamp aligning marks on the pump housing flange. (4)-
----------

----------
a=59deg36min+-3deg b=0deg24min+-30min




Information:


Illustration 74 g02026337 Appendix D
Cleaned Filter Specification
Note: Scope: The following steps determine a properly cleaned Caterpillar filter.Note: This specification applies to filters that were cleaned of ash only. This specification is only valid subsequent to the "Recommended Cleaning Procedure". This specification should not be used to determine if soot filled filters are properly cleaned. All filters must be baked appropriately using the "Recommended Cleaning Procedure" prior to application of this specification.HEALTH AND SAFETY
Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.
Adhere to all local Health and Safety rules and regulations. Use all the personal protective equipment listed below:
Respirator
Safety shoes
Safety glasses
Latex gloves
Lab coatRESOURCESNecessary equipment:
38 cm (15 inch) long by 0.9 mm (0.04 inch) thick stainless steel probe for "200 cpsi" (Cells/Square inch) filters
Tape measureMETHODEvaluation of a cleaned filter:Note: A filter MUST meet all criteria in this section below to be considered clean.
Inspect both inlet and outlet surfaces for oil/fuel contamination, gouges and/or cracks. No cracks may be visible. Gouges may not be exceed 4.0 mm (0.15 inch) deep.
There must be no filter movement within the filters banding. This movement is defined as the substrate moving past the bent-over flange. The filter must be even or below the bent-over flange.
There must not be any signs of the steel fiber ring coming loose or any mat material (cottony gauze) slipping past the filter. See Illustration 75 below.
The flanges are not damaged beyond repair.
There are no dents deeper than 6.4 mm (0.25 inch) in the outer can of the filter and the outer can is not cracked, torn or otherwise breached.
No more than 20 cells are allowed to be damaged (showing soot) on the outlet face of the filter. Refer to Illustrations 76 and 77.
Inspect the ash depth in the cells using the "Check Cell Depth" instructions below.
Illustration 75 g02026392
Proper placement of the filter within the banding
(1) Outside Can
(2) Bent-over flange
(3) Steel fiber ring
(4) Mat material
(5) FilterNote: Filter must be below the bent over-flange (2).
Illustration 76 g02026398
Acceptable filter with less than 20 damaged cells
Illustration 77 g02026399
Unacceptable filter with too many damaged cells
Check Cell Depth
Check cell depth by dropping the stainless steel probe into a cell location noted by a dot in Illustration 78 below.
Lightly tap the probe with a finger until the probe does not travel into the cell any further. Mark the probe to record the depth.
Illustration 78 g02026405
Measure the distance from the tip of the probe which entered the cell to the mark made on the probe. This distance is the cell depth. Repeat this step 17 times per Illustration 78.
If the probe travels a minimum of 28.6 cm (11.25 inch) in all cells, the filter is considered clean.
If the probe encounters heavy resistance in

Have questions with 101495-3150?





Group cross 101495-3150 ZEXEL

Komatsu 

 
6204711631 
INJECTION-PUMP ASSEMBLY
4D95L
 
6204711731 
INJECTION-PUMP ASSEMBLY
4D95L
F 019 Z10 164 
6204711271 
INJECTION-PUMP ASSEMBLY
4D95L
 
6204711261 
INJECTION-PUMP ASSEMBLY
4D95L
 
6202731142 
INJECTION-PUMP ASSEMBLY
4D95S
101495-3150  
9 400 614 515 
6202731181 
INJECTION-PUMP ASSEMBLY
4D95S
9 400 614 516 
6202731131 
INJECTION-PUMP ASSEMBLY
4D95S
 
 