101493-9210 ZEXEL F 019 Z10 334 BOSCH INJECTION-PUMP ASSEMBLY f019z10334 1014939210


 

Information injection-pump assembly

BOSCH F 019 Z10 334 f019z10334
ZEXEL 101493-9210 1014939210
101493-9210 INJECTION-PUMP ASSEMBLY
Rating:
57
Buy INJECTION-PUMP ASSEMBLY 101493-9210 zexel genuine, new aftermarket engine parts with delivery

Service parts 101493-9210 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-9810
3. GOVERNOR 105921-6750
4. SUPPLY PUMP 105220-6020
5. AUTOM. ADVANCE MECHANIS 105671-0330
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5501
11. Nozzle and Holder 166000T003
12. Open Pre:MPa(Kqf/cm2) 18.6(190)
13. NOZZLE-HOLDER 105048-3760
14. NOZZLE 105017-1320
15. NOZZLE SET

Include in #1:

101493-9210 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH F 019 Z10 334 f019z10334
ZEXEL 101493-9210 1014939210


Zexel num
Bosch num
Firm num
Name
101493-9210 
101493-9211 
F 019 Z10 334 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-1520
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.2 3.15 3.25
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.7
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   74 72.4 75.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   9.6 7.8 11.4
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.7)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   74 73 75
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.2
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   80.9 76.9 84.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   100 84 116
Fixing the lever   *
Timer adjustment
Pump speed r/min   1010--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   960
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   (1000)
Advance angle deg.   0.8 0.5 1.1
Remarks
Measure the actual speed.
 
Timer adjustment_04
Pump speed r/min   1330+30- 20
Advance angle deg.   0.8 0.5 1.1
Timer adjustment_05
Pump speed r/min   1500
Advance angle deg.   3.45 3.45 3.45
Timer adjustment_06
Pump speed r/min   1600
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101493-9210
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=G84
----------

Speed control lever angle

Test data 101493-9210
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=32mm
----------
a=70deg+-5deg b=(36deg)+-3deg

Stop lever angle

Test data 101493-9210
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=12mm
----------
a=29deg+-5deg b=10deg+-5deg

Timing setting

Test data 101493-9210
(1)Pump vertical direction (2)Position of gear's standard threaded hole (position of gear mark 'S') at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(60deg)




Information:


Illustration 1 g00564355
7W-2743 Electronic Speed Switch (ESS)
(1) Push button for Overspeed Verification
(2) Reset button
(3) Overspeed indicator lamp
(4) Seal screw plug for adjusting the engine overspeed
(5) Seal screw plug for adjusting the crank terminate speed
(6) Seal screw plug for adjusting the oil step pressure speed setting The calibration of the crank terminate adjustment can increase the crank terminate speed or the calibration of the crank terminate adjustment can decrease the crank terminate speed. The crank terminate speed determines when the starting motor is disengaged. The starting motor is disengaged when the system voltage is cancelled by the crank termination speed. At the crank terminate speed, the engine must be able to run without the assistance of the starting motor.
Remove the lockwire and the seal from seal screw plug (5). Remove seal screw plug (5) from the access hole for the crank terminate adjusting screw.
Use a small screwdriver to lightly turn the crank terminate adjusting screw in the direction of the "MAX" arrow or the clockwise direction. Turn the screw twenty times. The crank terminate adjusting screw will vary the setting of a potentiometer that is inside of the ESS. The crank terminate adjusting screw will not cause damage to the potentiometer. Also, the screw can not be removed if the screw is turned in the wrong direction.
Turn the crank terminate adjusting screw for twelve turns in the opposite direction of the "MAX" arrow or the counterclockwise direction. This will establish an approximate crank terminate setting.
Connect a voltmeter with the positive lead at terminal (ESS-12) and the negative lead at (ESS-5). Use a 6V-7070 Digital Multimeter or a voltmeter with the same accuracy. Start the engine. Record the engine rpm when the starting motor disengages. The starting motor disengages when the open circuit voltage is cancelled by the crank terminate setting. Refer to the Speed Specification Chart for the correct crank terminate setting.
If the setting in Step 4 is not correct, proceed with Steps 6, 7, and 8. If the setting is correct go to Step 8.
Stop the engine and turn the crank terminate adjusting screw for one full turn in the clockwise direction in order to increase the crank terminate speed. Turn the crank terminate adjusting screw for one full turn in the counterclockwise direction in order to decrease the crank terminate speed.
While the voltmeter is still connected, start the engine. Record the engine rpm when the starting motor disengages. The starting motor will disengage when the voltage is cancelled by the crank terminate speed. Repeat Steps 6 and 7 until the crank terminate speed is correct.
Install seal screw plug (5) in the access hole for the crank terminate adjusting screw. Tighten the screw to a torque of 0.20 0.03 N m (1.8 .3 lb in). Install the lockwire and the seal if the overspeed calibration and the oil step speed calibration are also complete.

Have questions with 101493-9210?





Group cross 101493-9210 ZEXEL

101493-9210  

101493-9211 
F 019 Z10 334 
 
INJECTION-PUMP ASSEMBLY
F 019 Z10 335 
 
INJECTION-PUMP ASSEMBLY

Nissan 

F 019 Z10 336 
167000T070 
INJECTION-PUMP ASSEMBLY
FD42

Nissan-Diesel 

F 019 Z10 336 
167000T070 
INJECTION-PUMP ASSEMBLY
FD42

Nissan 

9 400 610 552 
167000T046 
INJECTION-PUMP ASSEMBLY
FD42

Nissan-Diesel 

9 400 610 552 
167000T046 
INJECTION-PUMP ASSEMBLY
FD42
Back to top