101491-9603 ZEXEL 9 400 614 345 BOSCH INJECTION-PUMP ASSEMBLY 9400614345 1014919603 slf513800c


 

Information injection-pump assembly

BOSCH 9 400 614 345 9400614345
ZEXEL 101491-9603 1014919603
MAZDA SLF513800C slf513800c
101491-9603 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 101491-9603 zexel genuine, new aftermarket engine parts with delivery

Service parts 101491-9603 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-9480
3. GOVERNOR 105921-3560
4. SUPPLY PUMP 105220-7030
5. AUTOM. ADVANCE MECHANIS 105670-0341
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4252
11. Nozzle and Holder SL50 13 H50A
12. Open Pre:MPa(Kqf/cm2) 16.7{170}
13. NOZZLE-HOLDER 105048-3121
14. NOZZLE 105017-0211
15. NOZZLE SET

Include in #1:

101491-9603 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101491-9603 
9 400 614 345 
SLF513800C  MAZDA
INJECTION-PUMP ASSEMBLY
SL-T/C K 14BC INJECTION PUMP ASSY PE4A,5A, PE




Information:

Introduction
The objective of this topic is to assist users in establishing a Preventive Maintenance Program for Standby Generator Sets or as an aid in evaluating their present programs.Standby Generator Sets may not be needed very often, but when they are, it is usually under emergency conditions. Maintenance of these standby units is very important. They must always be in excellent operating condition, ready to work under load at any time.Establishing a Preventive Maintenance Program will provide maximum availability of a standby generator set when needed, longer engine and generator life, and a minimum of expensive repairs.The recommended WEEKLY maintenance checks can be performed by an operator. The checks consist of basic maintenance requirements to ensure the standby generator set will be ready for immediate use should the need arise.All YEARLY and THREE YEAR maintenance should be performed by an authorized mechanic or your Caterpillar dealer. These checks and maintenance requirements will require that the standby generator be run under load conditions, and may require special test equipment.These guidelines are to be used with the information contained in the Operation and Maintenance sections of this manual. The Operation and Maintenance sections of the manual will provide the necessary information on how to perform the checks and routine maintenance.Refer to the Generator and Engine Service Manuals and Recommended Preventive Maintenance Schedules for Standby Generator Sets, SEBU6042 for additional information, or contact your Caterpillar dealer for assistance.Inspection and Maintenance Agreements
Your Caterpillar dealer can establish an Inspection and Preventive Maintenance Program for your generator set to provide maximum reliability, increased engine and generator life, and minimize expensive repairs. Contact your Caterpillar dealer for details.General Recommendations
Safety
The stop-manual-automatic switch on the cranking panel must be set at STOP position when performing maintenance or repair work on a standby generator set. This prevents the unit from starting if a power failure or voltage drop should occur while working on the unit.To prevent personal injury due to accidental starting of the engine, disconnect the batteries or disable the starting system before doing maintenance or repair work.Lock out all switch gear and automatic transfer switches associated with the generator while performing any generator maintenance or repairs. Make sure no shock hazard exists.Failure to comply could result in personal injury or death.
Always make repairs with the engine stopped and the starting system disabled. When servicing the generator, make sure that switch gear and automatic transfer switches will not present a shock hazard. Lock them out on the generator being serviced.Record Keeping
Maintain a log or record keeping system to document all gauge readings, problems, repairs, and maintenance performed on the equipment.Space Heaters
Moisture is a natural enemy of generators and all electrical equipment. Every effort must be made to keep the generator as dry as possible. Space heaters should be operated inside the generator when it is not in use to maintain the integrity of the generator windings.

Have questions with 101491-9603?





Group cross 101491-9603 ZEXEL

Mazda 

 
SLF513800A 
INJECTION-PUMP ASSEMBLY
SL-T/C
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

101491-9603  
9 400 614 345 
SLF513800C 
INJECTION-PUMP ASSEMBLY
SL-T/C

Nissan-Diesel 

 
1670054T64 
INJECTION-PUMP ASSEMBLY
BD2
 
1670054T65 
INJECTION-PUMP ASSEMBLY
BD2

Mazda 

 
SLB113800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SLB113800A 
INJECTION-PUMP ASSEMBLY
SL
9 400 610 532 
SLB113800B 
INJECTION-PUMP ASSEMBLY
SL
9 400 611 885 
SLB113800C 
INJECTION-PUMP ASSEMBLY
SL
 
SLB313800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SLB313800A 
INJECTION-PUMP ASSEMBLY
SL
9 400 619 906 
SLB313800B 
INJECTION-PUMP ASSEMBLY
SL
9 400 614 346 
SLB313800C 
INJECTION-PUMP ASSEMBLY
SL
 
SLB213800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

9 400 614 347 
SLB213800A 
INJECTION-PUMP ASSEMBLY
SL
 
SLB413800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SLB413800A 
INJECTION-PUMP ASSEMBLY
SL
 
SLF413800A 
INJECTION-PUMP ASSEMBLY
SL-T/C
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SLF413800C 
INJECTION-PUMP ASSEMBLY
SL-T/C
 
SL8913800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SL8913800B 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

F 019 Z10 817 
1679090304 
INJECTION-PUMP ASSEMBLY
FD3504
Back to top