101491-9593 ZEXEL 9 400 610 531 BOSCH INJECTION-PUMP ASSEMBLY 9400610531 1014919593 slb513800b


 

Information injection-pump assembly

BOSCH 9 400 610 531 9400610531
ZEXEL 101491-9593 1014919593
MAZDA SLB513800B slb513800b
101491-9593 INJECTION-PUMP ASSEMBLY
Rating:
19
Buy INJECTION-PUMP ASSEMBLY 101491-9593 zexel genuine, new aftermarket engine parts with delivery

Service parts 101491-9593 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-5010
3. GOVERNOR 105921-8920
4. SUPPLY PUMP 105220-7030
5. AUTOM. ADVANCE MECHANIS 105670-0080
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4091
11. Nozzle and Holder SL01 13 640A
12. Open Pre:MPa(Kqf/cm2) 16.7{170}
13. NOZZLE-HOLDER 105048-3121
14. NOZZLE 105017-2070
15. NOZZLE SET

Include in #1:

101491-9593 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101491-9593 
101491-9594 
9 400 610 531 
SLB513800B  MAZDA
INJECTION-PUMP ASSEMBLY
SL * K




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with Every 1000 Hour maintenance, perform all previous maintenance interval requirements.Engine Protection Devices
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A

Have questions with 101491-9593?





Group cross 101491-9593 ZEXEL

Mazda 

 
SLB513800 
INJECTION-PUMP ASSEMBLY
SL
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
SLB513800A 
INJECTION-PUMP ASSEMBLY
SL
101491-9593  

101491-9594 
9 400 610 531 
SLB513800B 
INJECTION-PUMP ASSEMBLY
SL
9 400 613 153 
SLB513800C 
INJECTION-PUMP ASSEMBLY
SL
Back to top