101491-0541 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014910541 8970295910


 

Information injection-pump assembly

ZEXEL 101491-0541 1014910541
ISUZU 8970295910 8970295910
101491-0541 INJECTION-PUMP ASSEMBLY
Rating:
68
Buy INJECTION-PUMP ASSEMBLY 101491-0541 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

ZEXEL 101491-0541 1014910541
ISUZU 8970295910 8970295910


Zexel num
Bosch num
Firm num
Name
101491-0541 
101491-0542 
 
8970295910  ISUZU
INJECTION-PUMP ASSEMBLY
4BE1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.8 3.75 3.85
Rack position
After adjusting injection quantity.
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.2
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   52.4 50.8 54
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.9+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   13.3 12 14.6
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.2)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   52.4 51.4 53.4
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(12.2)
Pump speed r/min   1750 1750 1750
Average injection quantity mm3/st.   65.9 61.9 69.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   86 70 102
Fixing the lever   *
Timer adjustment
Pump speed r/min   1525--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1475
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1775
Advance angle deg.   4.5 4 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101491-0541
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)At delivery (at R = A, N = N1)
----------
T1=F38 N1=100r/min
----------

Speed control lever angle

Test data 101491-0541
F:Full speed I:Idle (1)Stopper bolt set position 'H' (2)Set the idle side stopper bolt at speed = aa and rack position = bb (at delivery)
----------
aa=100r/min bb=R1(12.2)mm
----------
a=(8deg) b=(37deg)+-3deg c=3.5deg+-5deg

Stop lever angle

Test data 101491-0541
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=45deg+-5deg b=29deg+-5deg

0000001501 I/P WITH LOAD PLUNGER ADJ

Plunger assembly number: PL (stamping: ST) 1. Adjustment procedures (1)Insert the pre-stroke adjusting shims L1 for each cylinder. (2)Adjust injection quantity.(max. var. bet. cyl. idling a1, full a2) (3)At basic point A, adjust so that the pre-stroke is L2. (4)Reconfirm the injection quantity.
----------
PL=131154-1820 ST=A260 L1=1mm L2=3.8+-0.05mm a1=+-14% a2=+-2.5%
----------

Timing setting

Test data 101491-0541
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=15deg
----------
a=(100deg)




Information:


Governor Linkage Adjustment
(1) Rod. (2) Nut. (3) Control lever. (4) Lever. (5) Pin. (6) High idle stop. (7) Locknut. (8) Low idle stop. (9) Locknut. (10) Decelerator treadle. (11) Floor plate. (12) Accelerator treadle. (13) Lever. (14) Rod. (15) Locknut. (16) Lever. (17) Locknut. (A) 9.7 mm (.38 in). (B) 4.8 mm (.19 in). (C) 38.1 mm (1.50 in). (D) 60.5 3.0 mm (2.38 .12 in). DO NOT USE control lever (3), or decelerator treadle (10) to shut OFF the engine.To shut engine OFF, pull up on accelerator treadle (12).1. Tighten nut (2) just enough so position of control lever (3) is not affected by the operation of the accelerator treadle (12) and decelerator treadle (10).2. With the parking brake ON and engine stopped, BE SURE disconnect switch is OFF.3. Remove pin (5).4. Loosen LOW IDLE stop (8) and HIGH IDLE stop (6) so they do not touch lever (13).5. Move control lever (3) to LOW IDLE position.6. Turn LOW IDLE stop (8) until it touches lever (13) and tighten locknut (9).7. Adjust length of rod (14) so distance from top of lever (16) to bottom of floor plate (11) is (C) 38.1 mm (1.50 in) as shown.8. Loosen locknut (15) and adjust length of rod so top of decelerator treadle (10) is (B) 4.8 mm (.19 in) above floor plate (11) as shown. If machine is equipped with a thick floor insulation pad, (used with enclosed cab), adjust decelerator treadle (10) so top of treadle is (A) 9.7 mm (.38 in) above top of floor plate and tighten locknut (15).9. Move control lever (3) to HIGH IDLE position.10. Turn HIGH IDLE stop (6) until it touches lever (13) and tighten locknut (7).11. Loosen locknut (17) and adjust accelerator treadle (12) so that distance from bottom of plate on treadle to top of floor plate (11) is (D) 60.5 3.0 mm (2.38 .12 in) as shown.12. Move lever (4) to HIGH IDLE position and adjust length of rod (1) so pin (5) can be installed.13. Install pin (5).
DO NOT adjust the linkage so the treadle can be used to shut off the engine. If the operator is in a standing position and places a foot on the treadle, the engine could be unexpectedly shut off, creating a situation where the machine can be difficult to control.
518 Skidder
1. Move governor shaft (3) to SHUT OFF position and install lever (2) on shaft (3) at angle (A).2. Adjust length of rod (5) so stop (4) on pedal (1) is at dimension (B) from the floor plate.Angle (A) ... 35 5°Dimension (B) ... 67 1 mm (2.64 .01 in)3. Tighten nut (6) ... 12 4 N m (9 3 lb ft)D5H
1. Move governor lever (2) to high idle and install spring (6). Move governor lever (2) to vertical position and adjust stop bolt (3) to contact lever (2), back off one turn and lock.2. Position lever (9) on the splined governor shaft

Have questions with 101491-0541?





Group cross 101491-0541 ZEXEL

Isuzu 

 
8970251400 
INJECTION-PUMP ASSEMBLY
4BE1
101491-0541  

101491-0542 
 
8970295910 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970315600 
INJECTION-PUMP ASSEMBLY
4BE1
F 019 Z10 815 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
8970318680 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970386140 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970439710 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 291 
8970439712 
INJECTION-PUMP ASSEMBLY
4BE1
Back to top