101491-0161 ZEXEL 9 400 610 021 BOSCH INJECTION-PUMP ASSEMBLY 9400610021 1014910161 5156013711


 

Information injection-pump assembly

BOSCH 9 400 610 021 9400610021
ZEXEL 101491-0161 1014910161
ISUZU 5156013711 5156013711
101491-0161 INJECTION-PUMP ASSEMBLY
Rating:
54
Buy INJECTION-PUMP ASSEMBLY 101491-0161 zexel genuine, new aftermarket engine parts with delivery

Include in #1:

Cross reference number

BOSCH 9 400 610 021 9400610021
ZEXEL 101491-0161 1014910161
ISUZU 5156013711 5156013711


Zexel num
Bosch num
Firm num
Name
101491-0161 
101491-0163 
9 400 610 021 
5156013711  ISUZU
INJECTION-PUMP ASSEMBLY
4BC2 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.4 3.35 3.45
Rack position   R=10.2
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.2
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   51 49.4 52.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.8+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   9.5 8 11
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.2)
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   51 50 52
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1800 1800 1800
Average injection quantity mm3/st.   49.2 47.6 50.8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.1
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   40 38.4 41.6
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   15++
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   73 65 81
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   D
Rack position   R1+0.8
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   42.1 40.1 44.1
Fixing the lever   *
Timer adjustment
Pump speed r/min   1650--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1600
Advance angle deg.   0.6
Timer adjustment_03
Pump speed r/min   1800
Advance angle deg.   3 2.5 3.5
Timer adjustment_04
Pump speed r/min   1900
Advance angle deg.   4.5 4 5
Timer adjustment_05
Pump speed r/min   -
Advance angle deg.   5 5 5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101491-0161
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1
----------
T1=55
----------

Speed control lever angle

Test data 101491-0161
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=5.5deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101491-0161
N:Pump normal S:Stop the pump.
----------

----------
a=35deg+-5deg b=40deg+-5deg

Timing setting

Test data 101491-0161
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=15deg
----------
a=(100deg)




Information:

Changing Filter Element
A 1U-9578 Repair Kit (Nozzle Tester) is available to maintain the tester. The repair kit contains a new filter along with seals, gaskets, and instructions on how to use the kit. Do not reuse seals and gaskets when changing the filter. Always use new seals and gaskets.Calibration Fluid
The calibration fluid should be changed every three months or after testing 50 nozzles. The fluid should also be changed whenever inaccurate test results are suspected.Inaccurate test results can be caused by fluid with improper specific gravity, viscosity, visible contamination, fluid that foams, or discolored fluid.The fluid should also be checked for the correct viscosity. It is a good practice to test new calibration fluid for the correct viscosity and specific gravity. Use a 9U-7840 Test Kit to check calibration fluid.
Do not refill the nozzle tester with test oil that has been pumped through a fuel injection nozzle. Nozzles contain residual amounts of diesel fuel that is pumped out when tested. The diesel fuel mixes with and contaminates the test oil. Using this diesel fuel test oil combination will damage the nozzle tester.
9U-7840 Test Kit For Checking Fluid Viscosity Calibration fluid will last longer if the nozzles are cleaned prior to testing. As the fluid in the tester becomes contaminated, the accuracy of the test results are decreased.Changing Calibration Fluid
1. Completely drain the reservoir and any fluid contained in the pump mechanism. Special care must be taken for the disposal of the calibration fluid. Recent regulations prohibit the dumping of oil; all oil must be properly disposed.2. Thoroughly clean the reservoir using an 8T-9011 Component Cleaner or equivalent and clean towels.3. Install a new 8T-5313 Filter Element (10 micron). A new filter element should be installed whenever the calibration fluid is changed (even if less than 3 months).4. Fill the reservoir with clean calibration fluid (refer to the chart for part numbers).Nozzle Tester Pressure Gauges
Pressure gauges in the nozzle tester should be checked for accuracy every 12 months or whenever inaccurate test results are suspected. Gauges should also be checked whenever a gauge is damaged or the needle does not return to zero. Record all data on the data sheets in the "Forms" section.1. Remove pressure gauge from the nozzle tester.2. Install gauge adapter from 5P-8558 Calibrating Group Pressure Gauge onto pressure gauge.3. Connect pressure to tester port.4. Use a 1U-5230 Hand Pump to apply pressure to the gauge. Increase the pressure to 25% of the pressure gauges capacity.5. Check the actual gauge pressure with the tester gauge reading. The two pressures should be within two percent of each other.6. Repeat Step 5 at 50, 75 and 100 percent increments. Each increment should be within two percent of the tester gauge reading.7. If the pressure is not within two percent, the pressure gauge should be replaced.Check Tester For Leakage
Before testing any nozzle, check the tester for obvious external leakage. Leakage in the tester will give inaccurate test results, causing good nozzles to be rejected.Always check the tester for leakage

Have questions with 101491-0161?





Group cross 101491-0161 ZEXEL

Isuzu 

 
5156013930 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013931 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013932 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013933 
INJECTION-PUMP ASSEMBLY
4BC2
9 400 614 269 
5156013935 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013770 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013771 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013780 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013781 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156014110 
INJECTION-PUMP ASSEMBLY
4BC2
9 400 614 270 
5156014111 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013680 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013681 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013682 
INJECTION-PUMP ASSEMBLY
4BC2
9 400 614 271 
5156013684 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013700 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013701 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013710 
INJECTION-PUMP ASSEMBLY
4BC2
101491-0161  

101491-0163 
9 400 610 021 
5156013711 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013712 
INJECTION-PUMP ASSEMBLY
4BC2
F 01G 09U 01R 
5156013713 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013720 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013721 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013730 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013731 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013732 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013733 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013734 
INJECTION-PUMP ASSEMBLY
4BC2
9 400 614 272 
5156013735 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013740 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013741 
INJECTION-PUMP ASSEMBLY
4BC2
Back to top