101491-0032 ZEXEL 9 400 610 014 BOSCH INJECTION-PUMP ASSEMBLY 9400610014 1014910032 5156012105


 

Information injection-pump assembly

BOSCH 9 400 610 014 9400610014
ZEXEL 101491-0032 1014910032
ISUZU 5156012105 5156012105
101491-0032 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 101491-0032 zexel genuine, new aftermarket engine parts with delivery

Service parts 101491-0032 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101049-8150
3. GOVERNOR 105931-0681
4. SUPPLY PUMP 105220-5050
5. AUTOM. ADVANCE MECHANIS 105622-0861
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5120
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 18.1(185)
13. NOZZLE-HOLDER 105031-3700
14. NOZZLE 105015-4740
15. NOZZLE SET

Include in #1:

101491-0032 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101491-0032 
9 400 610 014 
5156012105  ISUZU
INJECTION-PUMP ASSEMBLY
4BC2 * K




Information:

Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Move starting control switch to energize the starter solenoid. Starter solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Energize the starter solenoid and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a faulty circuit from the battery. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and energize the starter solenoid. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates the starter switch or wiring is the fault.Attach one lead of the voltmeter to the starter switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch.A starting motor that operates too slow can be overloaded by excessive mechanical friction within the engine being started. Slow starting motor operation can also be caused by shorts, loose connections and/or excessive dirt within the motor.Pinion Clearance Adjustment (Prestolite)
There are two adjustments on this type motor. Armature end play and pinion position.Armature End Play
Adjust the end play to .005 to .030 in. (0.13 to 0.76 mm) by adding or removing thrust washers on the commutator end of the armature shaft.Pinion Position
This adjustment is accomplished in two steps.1. To adjust the pinion distance, connect the solenoid to a 12 volt battery as shown.Momentarily flash the jumper lead from the motor terminal stud of the solenoid to the terminal stud at (1) in the commutator end head to shift the solenoid and drive into the cranking position.
CONNECTIONS FOR ADJUSTING THE PINION POSITION
1. Jumper lead flashing point.Remove the jumper lead. The drive will remain in the cranking position until the battery is disconnected.Push the drive toward the commutator end of the motor to eliminate any slack movement in the linkage and measure the distance between the outside edge of the drive sleeve and the thrust washer. The distance (3) must be .02 to .05 in. (0.5 to 1.3 mm).Adjust to this dimension by turning the adjusting nut (2) in or out as required.
PINION POSITION ADJUSTMENT
2. Adjusting nut. 3. Distance.2. To test assembly of solenoid, it will be necessary to have an interference block cut to the dimensions shown.
INTERFERENCE BLOCK DIMENSIONSConnect the solenoid to 24 volts as

Have questions with 101491-0032?





Group cross 101491-0032 ZEXEL

Isuzu 

 
5156012032 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012035 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012036 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012071 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012074 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012075 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012091 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012094 
INJECTION-PUMP ASSEMBLY
4BC2
F 019 Z20 392 
5156012095 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012101 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156012104 
INJECTION-PUMP ASSEMBLY
4BC2
101491-0032  
9 400 610 014 
5156012105 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156011961 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156011964 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156011965 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013320 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013220 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013370 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013670 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013671 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013672 
INJECTION-PUMP ASSEMBLY
4BC2
9 400 614 268 
5156013674 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013690 
INJECTION-PUMP ASSEMBLY
4BC2
 
5156013691 
INJECTION-PUMP ASSEMBLY
4BC2
Back to top