Information injection-pump assembly
ZEXEL
101461-0460
1014610460
ISUZU
5156014190
5156014190

Rating:
Cross reference number
ZEXEL
101461-0460
1014610460
ISUZU
5156014190
5156014190
Zexel num
Bosch num
Firm num
Name
101461-0460
5156014190 ISUZU
INJECTION-PUMP ASSEMBLY
4BA1 * K
4BA1 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
1.95
1.9
2
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
-
Rack position
11.1
Pump speed
r/min
1750
1750
1750
Average injection quantity
mm3/st.
45.8
44.3
47.3
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
8.9+-0.5
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
8.5
7.1
9.9
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
-
Rack position
16.5++
Pump speed
r/min
150
150
150
Average injection quantity
mm3/st.
75
75
Fixing the lever
*
Remarks
Excess fuel for starting.
Excess fuel for starting.
Injection quantity adjustment_04
Adjusting point
-
Rack position
-
Pump speed
r/min
1750
1750
1750
Average injection quantity
mm3/st.
45.8
45.3
46.3
Remarks
Smoke setting
Smoke setting
Timer adjustment
Pump speed
r/min
500
Advance angle
deg.
0.5
Timer adjustment_02
Pump speed
r/min
700
Advance angle
deg.
1
Timer adjustment_03
Pump speed
r/min
1000
Advance angle
deg.
1.5
1
2
Timer adjustment_04
Pump speed
r/min
1400
Advance angle
deg.
4
3.5
4.5
Timer adjustment_05
Pump speed
r/min
1750
Advance angle
deg.
6
6
7
Remarks
Finish
Finish
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
P:Negative pressure
(1)Pneumatic governor
(2)Mechanical governor
(3)Adjustment speed N1
(4)Beginning of idle sub spring operation: L1
(5)Acting negative pressure: P1
(6)Injection quantity Q = Q1 or less
----------
N1=500r/min L1=9.1+-0.5mm Q1=3mm3/st
----------
----------
N1=500r/min L1=9.1+-0.5mm Q1=3mm3/st
----------
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=10deg
----------
a=(100deg)
----------
aa=10deg
----------
a=(100deg)
Information:
Repeat Steps 4 through 6 to remove (bleed) air from the rear table lift cylinder (not shown).
Open (CCW) hand pump control knob (11) to completely lower the DPF cleaner table. Close (CW) the hand pump control knob.
Illustration 38 g02728258
(28) Hydraulic Oil Level 51 to 102 mm (2.0 to 4.0 inch)
Check the oil level in the pump reservoir. Remove fill cap (13) located on the end cap of the hand pump. Hydraulic oil level (28) should be 51 to 102 mm (2.0 to 4.0 inch) from the bottom of the fill hole. Add high-grade hydraulic oil, if needed.Note: A clean wire tie can be used as a dipstick to measure the hydraulic oil level in the pump reservoir.Troubleshooting Guide
Table 3
Symptom     Solution    
Air dryer desiccant is a pinkish color.     1. Replace or regenerate the desiccant. Refer to ""Maintenance Section"".    
Bursting does not occur.     1. Check display screen for error message.
2. Check power connection to burst valve solenoid.    
Cabinet doors do not close correctly.     1. Look for damaged door hinges, seals, and latches.
2. Verify that vehicle sensors have been removed from DPF.    
Cabinet doors open during burst process.     1. Verify that doors are correctly latched.
2. Look for damage to door latches.
3. Check seals between DPF and adapters.    
Clamping force cannot be obtained.     1. Look for hydraulic fluid leaks.
2. Check fluid level in hydraulic pump. Refer to ""Maintenance Section"".    
Clamping force does not hold.     1. Upon initial clamping, it is possible for clamp load to drop
689 to 1379 kPa (99.9 to 200.0 psi) within the first minute, due to temperature effects. After reclamping, the drop should be virtually zero.
2. Look for hydraulic fluid leaks.    
Display screen is blank.     1. Verify that machine is ON, plugged into an outlet, and power is available to the outlet.
2. Reset circuit breakers located on left side of control cabinet.    
DPF does not line up correctly on the table.     1. Verify that correct adapters are being used.
2. Verify DPF is correctly seated on to lower adapter.    
DPF is damaged after cleaning process.     1. Check DPFs for damage before cleaning.
2. Look for damage on adapters.
3. Verify that correct cleaning protocol was entered into machine.    
DPF is not cleaned.     1. Check orientation of DPF. Refer to ""General Information"" Section.
2. Verify that correct cleaning protocol was entered into machine.
3. Look for other DPF conditions that may prevent successful cleaning.  
Have questions with 101461-0460?
Group cross 101461-0460 ZEXEL
Isuzu
101461-0460
5156014190
INJECTION-PUMP ASSEMBLY
4BA1
4BA1