Information injection-pump assembly
ZEXEL
101451-9110
1014519110
NISSAN-DIESEL
16700J5502
16700j5502

Rating:
Service parts 101451-9110 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
16600-Z5000
12.
Open Pre:MPa(Kqf/cm2)
11.8{120}
15.
NOZZLE SET
Cross reference number
Zexel num
Bosch num
Firm num
Name
101451-9110
16700J5502 NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
ED30 * K
ED30 * K
Information:
Introduction
The problem identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There have been some instances of faults with the 459-7216 DEF Injector & Mounting Gp. The faults can lead to the Diesel Exhaust Fluid (DEF) injector not dosing correctly. Diagnostic trouble codes and operator inducements may become active due to these faults.Solution
Follow the correct troubleshooting procedure for any diagnostic codes related to the DEF system. Refer to Troubleshooting for the correct procedure. Diagnostic code 3361–5 Aftertreatment #1 DEF Dosing Unit : Current Below Normal has been reported, which may lead to operator inducement diagnostic codes 5246-15 Aftertreatment SCR Operator Inducement : Severity : High - least severe (1) and 5246-16 Aftertreatment SCR Operator Inducement : Severity : High - moderate severity.If the troubleshooting procedure indicates a DEF injector fault, perform the following procedure:
Ensure that the latest engine software is installed on the engine ECM. Refer to Troubleshooting, ECM Software - Install for the correct procedure.
Illustration 1 g06123677
View of the 459-7216 DEF Injector & Mounting Gp
(1) DEF injector part number
(2) Cavity number
Record the DEF injector part number (1), serial number, and cavity number (2).Note: The cavity number will be either a "1", a "2", or a "3".
If the DEF injector serial number is between "SN150702094314" and "SN160722000000" and the cavity number is "1", continue with this procedure.If the DEF injector serial number is outside of the range specified above, proceed to Test Step 4.If the cavity number is "2" or a "3", proceed to Test Step 4.
Install a replacement DEF injector. Refer to
The problem identified below does not have a permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
There have been some instances of faults with the 459-7216 DEF Injector & Mounting Gp. The faults can lead to the Diesel Exhaust Fluid (DEF) injector not dosing correctly. Diagnostic trouble codes and operator inducements may become active due to these faults.Solution
Follow the correct troubleshooting procedure for any diagnostic codes related to the DEF system. Refer to Troubleshooting for the correct procedure. Diagnostic code 3361–5 Aftertreatment #1 DEF Dosing Unit : Current Below Normal has been reported, which may lead to operator inducement diagnostic codes 5246-15 Aftertreatment SCR Operator Inducement : Severity : High - least severe (1) and 5246-16 Aftertreatment SCR Operator Inducement : Severity : High - moderate severity.If the troubleshooting procedure indicates a DEF injector fault, perform the following procedure:
Ensure that the latest engine software is installed on the engine ECM. Refer to Troubleshooting, ECM Software - Install for the correct procedure.
Illustration 1 g06123677
View of the 459-7216 DEF Injector & Mounting Gp
(1) DEF injector part number
(2) Cavity number
Record the DEF injector part number (1), serial number, and cavity number (2).Note: The cavity number will be either a "1", a "2", or a "3".
If the DEF injector serial number is between "SN150702094314" and "SN160722000000" and the cavity number is "1", continue with this procedure.If the DEF injector serial number is outside of the range specified above, proceed to Test Step 4.If the cavity number is "2" or a "3", proceed to Test Step 4.
Install a replacement DEF injector. Refer to
Have questions with 101451-9110?
Group cross 101451-9110 ZEXEL
Nissan-Diesel
101451-9110
16700J5502
INJECTION-PUMP ASSEMBLY
ED30
ED30