101441-9880 ZEXEL 9 400 614 145 BOSCH INJECTION-PUMP ASSEMBLY 9400614145 1014419880


 

Information injection-pump assembly

BOSCH 9 400 614 145 9400614145
ZEXEL 101441-9880 1014419880
101441-9880 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 101441-9880 zexel genuine, new aftermarket engine parts with delivery

Include in #1:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101441-9880 
9 400 614 145 
  DAEWOO
INJECTION-PUMP ASSEMBLY
DC24T * K




Information:

password protection for the CCM is initially enabled. Password protection may be necessary for some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 101441-9880?





Group cross 101441-9880 ZEXEL

Dpico 

 
 
INJECTION-PUMP ASSEMBLY
C240
 
 
INJECTION-PUMP ASSEMBLY
C240

Nissan-Diesel 

9 400 610 507 
1679090370 
INJECTION-PUMP ASSEMBLY
TD2304

Daewoo 

9 400 613 079 
 
INJECTION-PUMP ASSEMBLY
DC24

Nissan-Diesel 

 
1671290176 
INJECTION-PUMP ASSEMBLY
TD2705
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 611 686 
1671290202 
INJECTION-PUMP ASSEMBLY
TD2705
 
1671290177 
INJECTION-PUMP ASSEMBLY
TD2705
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 611 193 
1671290203 
INJECTION-PUMP ASSEMBLY
TD2705
 
1679090371 
INJECTION-PUMP ASSEMBLY
TD2704
9 400 619 646 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 614 143 
1679090401 
INJECTION-PUMP ASSEMBLY
TD2704
 
1679090372 
INJECTION-PUMP ASSEMBLY
TD2704
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 614 144 
1679090402 
INJECTION-PUMP ASSEMBLY
TD2704

Daewoo 

101441-9880  
9 400 614 145 
 
INJECTION-PUMP ASSEMBLY
DC24T

Dpico 

 
 
INJECTION-PUMP ASSEMBLY
DC24
Back to top