Information injection-pump assembly
BOSCH
9 400 614 144
9400614144
ZEXEL
101441-9872
1014419872
NISSAN-DIESEL
1679090402
1679090402

Rating:
Service parts 101441-9872 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
1660043G03
12.
Open Pre:MPa(Kqf/cm2)
9.8(100)
15.
NOZZLE SET
Cross reference number
BOSCH
9 400 614 144
9400614144
ZEXEL
101441-9872
1014419872
NISSAN-DIESEL
1679090402
1679090402
Zexel num
Bosch num
Firm num
Name
101441-9872
9 400 614 144
1679090402 NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
TD2704 K 14BC INJECTION PUMP ASSY PE4A,5A, PE
TD2704 K 14BC INJECTION PUMP ASSY PE4A,5A, PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
2.15
2.1
2.2
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
12.1
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
45.5
44.5
46.5
Max. variation between cylinders
%
0
-4
4
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
8.5+-0.5
Pump speed
r/min
325
325
325
Average injection quantity
mm3/st.
8
6.9
9.1
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_03
Adjusting point
C
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
55
50
60
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
550--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
500
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1300
Advance angle
deg.
3.5
3
4
Timer adjustment_04
Pump speed
r/min
-
Advance angle
deg.
7.3
7.3
7.3
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT
(4)Rack difference between N = N1 and N = N2
----------
K=15 N1=1270r/min N2=750r/min
----------
----------
K=15 N1=1270r/min N2=750r/min
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=25deg+-5deg b=18deg+-5deg
----------
----------
a=25deg+-5deg b=18deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
(1)Normal
----------
----------
a=12deg+-5deg b=53deg+-5deg
----------
----------
a=12deg+-5deg b=53deg+-5deg
0000001501 GOV FULL LOAD ADJUSTMENT

Title1:Full load stopper adjustment
Title2:Governor set speed
LABEL1:Distinguishing
LABEL2:Pump speed (r/min)
LABEL3:Ave. injection quantity (mm3/st)
LABEL4:Max. var. bet. cyl.
LABEL5:Remarks
LABEL6:Distinguishing
LABEL7:Governor set speed (r/min)
LABEL8:Maximum no-load speed (r/min)
LABEL9:Remarks
(1)Adjustment conditions are the same as those for measuring injection quantity.
(2)At high idle rack position L
----------
L=7.6mm
----------
a1=A a2=B a3=C a4=- r1=1000r/min r2=1000r/min r3=1000r/min r4=- Q1=- Q2=45.5+-1mm3/st Q3=- Q4=- c1=- c2=+-4% c3=- c4=- a5=26 a6=25 a7=24 a8=23 a9=22 a10=21 a11=20 a12=19 a13=18 a14=17 a15=- r5=1300r/min r6=1250r/min r7=1200r/min r8=1150r/min r9=1100r/min r10=1050r/min r11=1000r/min r12=950r/min r13=900r/min r14=850r/min r15=- R5=1395+-32r/min R6=1340+-31r/min R7=1290+-30r/min R8=1235+-28r/min R9=1180+-27r/min R10=1130+-26r/min R11=1075+-25r/min R12=1020+-23r/min R13=965+-22r/min R14=915+-22r/min R15=-
----------
L=7.6mm
----------
a1=A a2=B a3=C a4=- r1=1000r/min r2=1000r/min r3=1000r/min r4=- Q1=- Q2=45.5+-1mm3/st Q3=- Q4=- c1=- c2=+-4% c3=- c4=- a5=26 a6=25 a7=24 a8=23 a9=22 a10=21 a11=20 a12=19 a13=18 a14=17 a15=- r5=1300r/min r6=1250r/min r7=1200r/min r8=1150r/min r9=1100r/min r10=1050r/min r11=1000r/min r12=950r/min r13=900r/min r14=850r/min r15=- R5=1395+-32r/min R6=1340+-31r/min R7=1290+-30r/min R8=1235+-28r/min R9=1180+-27r/min R10=1130+-26r/min R11=1075+-25r/min R12=1020+-23r/min R13=965+-22r/min R14=915+-22r/min R15=-
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'ZZ' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=16deg
----------
a=(100deg)
----------
aa=16deg
----------
a=(100deg)
Information:
Table 9
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $25     IID 25    
4     $07     Number of bytes    
5     $58     GSC number 1    
6, 7     $00 $82     PID $0082 GSC Fault Log Codes, Status, And Number of occurrences    
8, 9     $00 $BE     CID 190 (engine speed sensor fault)    
10     $C3     Count included, inactive fault, logged fault, standard FMI (3)    
11     $04     Occurrence count of 4    
12     $24     Checksum    
IID 00 is used to request additional information on a fault 500000070058008300BEC34DIID 00 - Special parameter Command
Table 10
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $00     IID 00    
4     $07     Number of bytes    
5     $00     Reply in ASCII format    
6     $58     GSC number 1    
7, 8     $00 $83     PID $0083 GSC Fault Log Request For Additional Data    
9, 10, 11     $00 $BE $C3     More information requested on CID 190 FMI 3    
12     $4D     Checksum    
IID 25 will contain the reply as PID $0084 5001250B58008400BEC303000C001102IID 25 - Single Parameter Read Response
Table 11
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $25     IID 25    
4     $0B     Number of bytes    
5     $58     GSC number 1    
6, 7     $00 $84     PID $0084 GSC Fault Log Response For Additional Data    
8, 9     $00 $BE     CID 190    
10     $C3     More information on FMI 3    
11     $03     Three occurrences of this fault    
12, 13     $00 $0C     First occurrence at 12 hours    
14, 15     $00 $11     Last occurrence at 17 hours    
16     $02     Checksum    Monitoring Generator Phase
The following example shows how to select which generator phase the GSC monitors.
Use IID 34 to write the parameters of PID $F0B0: 500034050048F0B0007FIID 34 - Single Parameter Write Request
Table 12
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $00     User's PC is the sending module    
3     $34     IID 34    
4     $05     Number of bytes    
5     $00     Reply in ASCII format    
6     $58     GSC number 1    
7, 8     $F0 $B0     PID $F0B0 Generator Phase Select    
9     $00     Phase A-B Voltage, Phase A Current    
10     $7F     Checksum    
IID 35 is the response from the CCM: 5001350458F0B0007EIID 35 - Single Parameter Write Response
Table
Have questions with 101441-9872?
Group cross 101441-9872 ZEXEL
Dpico
Nissan-Diesel
Daewoo
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
101441-9872
9 400 614 144
1679090402
INJECTION-PUMP ASSEMBLY
TD2704