Information injection-pump assembly
ZEXEL
101441-9871
1014419871

Rating:
Cross reference number
ZEXEL
101441-9871
1014419871
Zexel num
Bosch num
Firm num
Name
101441-9871
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
2.15
2.1
2.2
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
12.1
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
45.5
44.5
46.5
Max. variation between cylinders
%
0
-4
4
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
8.5+-0.5
Pump speed
r/min
325
325
325
Average injection quantity
mm3/st.
8
6.9
9.1
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_03
Adjusting point
C
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
55
50
60
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
550--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
500
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1300
Advance angle
deg.
3.5
3
4
Timer adjustment_04
Pump speed
r/min
-
Advance angle
deg.
7.3
7.3
7.3
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT
(4)Rack difference between N = N1 and N = N2
----------
K=15 N1=1270r/min N2=750r/min
----------
----------
K=15 N1=1270r/min N2=750r/min
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=25deg+-5deg b=18deg+-5deg
----------
----------
a=25deg+-5deg b=18deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
----------
----------
a=12deg+-5deg b=53deg+-5deg
----------
----------
a=12deg+-5deg b=53deg+-5deg
0000001501 GOV FULL LOAD ADJUSTMENT

Title1:Full load stopper adjustment
Title2:Governor set speed
LABEL1:Distinguishing
LABEL2:Pump speed (r/min)
LABEL3:Ave. injection quantity (mm3/st)
LABEL4:Max. var. bet. cyl.
LABEL5:Remarks
LABEL6:Distinguishing
LABEL7:Governor set speed (r/min)
LABEL8:Maximum no-load speed (r/min)
LABEL9:Remarks
(1)Adjustment conditions are the same as those for measuring injection quantity.
(2)At high idle rack position L
----------
L=7.6mm
----------
a1=A a2=B a3=C a4=- r1=1000r/min r2=1000r/min r3=1000r/min r4=- Q1=- Q2=45.5+-1mm3/st Q3=- Q4=- c1=- c2=+-4% c3=- c4=- a5=26 a6=25 a7=24 a8=23 a9=22 a10=21 a11=20 a12=19 a13=18 a14=17 a15=- r5=1300r/min r6=1250r/min r7=1200r/min r8=1150r/min r9=1100r/min r10=1050r/min r11=1000r/min r12=950r/min r13=900r/min r14=850r/min r15=- R5=1395+-32r/min R6=1340+-31r/min R7=1290+-30r/min R8=1235+-28r/min R9=1180+-27r/min R10=1130+-26r/min R11=1075+-25r/min R12=1020+-23r/min R13=965+-22r/min R14=915+-22r/min R15=-
----------
L=7.6mm
----------
a1=A a2=B a3=C a4=- r1=1000r/min r2=1000r/min r3=1000r/min r4=- Q1=- Q2=45.5+-1mm3/st Q3=- Q4=- c1=- c2=+-4% c3=- c4=- a5=26 a6=25 a7=24 a8=23 a9=22 a10=21 a11=20 a12=19 a13=18 a14=17 a15=- r5=1300r/min r6=1250r/min r7=1200r/min r8=1150r/min r9=1100r/min r10=1050r/min r11=1000r/min r12=950r/min r13=900r/min r14=850r/min r15=- R5=1395+-32r/min R6=1340+-31r/min R7=1290+-30r/min R8=1235+-28r/min R9=1180+-27r/min R10=1130+-26r/min R11=1075+-25r/min R12=1020+-23r/min R13=965+-22r/min R14=915+-22r/min R15=-
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'ZZ' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=16deg
----------
a=(100deg)
----------
aa=16deg
----------
a=(100deg)
Information:
Remote Fault Reset$00 $0D aUsed to reset faults on the CCM.
Table 2
(a)     $00 - $7F = Retain current CCM inactive fault status.
$80 - $FF = Reset CCM inactive fault.    Device ID Code$00 $80 aabbccUsed to read the device ID code from the CCM as well as other components on the data link. Each pair of bytes (aa, bb, cc) is sent LSB first.
Table 3
(aa)     Module ID: will always equal $61, data will be sent as $61 $00    
(bb)     Service Tool Support Change Level: $01, data will be sent as $01 $00    
(cc)     Application type:$FF $E0, data will be sent as $E0 $FF    CCM Error Codes$00 $82 abUsed to read the CCM Error Codes.
Table 4
(a)     bit 1 = Reserved    
(b) (1)     Fault Code Status    
bit 8     1 = RS-232C link message fault exists    
bit 7     1 = Miscellaneous Cat Data Link fault    
bit 6     1 = Invalid Cat Data message fault    
bit 5     1 = Internal buffer overflow on RS-232C or Data Data Link fault    
bit 4     1 = RS-232C short circuit fault    
bit 3     1 = Memory battery is weak    
bit 2     1 = M5X message error (checksum or byte count error)    
bit 1     1 = EEPROM fault    
( 1 ) A value of 0 (zero) in bits 1 through 8 indicates that particular fault does not exist.CCM Communication Rate Change Enable$AA $12 aUsed to determine if the CCM is connected to the host computer directly or remotely using a modem. Also used to enable or disable the host computers ability to change the communication rate of the RS-232C serial port.
Table 5
(a)     Bit 4     Reserved for Caterpillar.    
Bit 3 0 = Enable password protection
1 = Disable password protection    
Bit 2 0 = Enable baud rate change
1 = Disable baud rate change    
Bit 1 0 = Direct connection
1 = Modem connection    Access Level 1 Password$AA $87 aaaaaaaaUsed to read or program the Level 1 Password
Table 6
(aaaaaaaa)     Level 1 password in printable ASCII form. Must be at least 6, but no more than
Table 2
(a)     $00 - $7F = Retain current CCM inactive fault status.
$80 - $FF = Reset CCM inactive fault.    Device ID Code$00 $80 aabbccUsed to read the device ID code from the CCM as well as other components on the data link. Each pair of bytes (aa, bb, cc) is sent LSB first.
Table 3
(aa)     Module ID: will always equal $61, data will be sent as $61 $00    
(bb)     Service Tool Support Change Level: $01, data will be sent as $01 $00    
(cc)     Application type:$FF $E0, data will be sent as $E0 $FF    CCM Error Codes$00 $82 abUsed to read the CCM Error Codes.
Table 4
(a)     bit 1 = Reserved    
(b) (1)     Fault Code Status    
bit 8     1 = RS-232C link message fault exists    
bit 7     1 = Miscellaneous Cat Data Link fault    
bit 6     1 = Invalid Cat Data message fault    
bit 5     1 = Internal buffer overflow on RS-232C or Data Data Link fault    
bit 4     1 = RS-232C short circuit fault    
bit 3     1 = Memory battery is weak    
bit 2     1 = M5X message error (checksum or byte count error)    
bit 1     1 = EEPROM fault    
( 1 ) A value of 0 (zero) in bits 1 through 8 indicates that particular fault does not exist.CCM Communication Rate Change Enable$AA $12 aUsed to determine if the CCM is connected to the host computer directly or remotely using a modem. Also used to enable or disable the host computers ability to change the communication rate of the RS-232C serial port.
Table 5
(a)     Bit 4     Reserved for Caterpillar.    
Bit 3 0 = Enable password protection
1 = Disable password protection    
Bit 2 0 = Enable baud rate change
1 = Disable baud rate change    
Bit 1 0 = Direct connection
1 = Modem connection    Access Level 1 Password$AA $87 aaaaaaaaUsed to read or program the Level 1 Password
Table 6
(aaaaaaaa)     Level 1 password in printable ASCII form. Must be at least 6, but no more than
Have questions with 101441-9871?
Group cross 101441-9871 ZEXEL
Dpico
Nissan-Diesel
Daewoo
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
Nissan-Diesel
101441-9871
INJECTION-PUMP ASSEMBLY