Information injection-pump assembly
ZEXEL
101441-9670
1014419670
NISSAN-DIESEL
1671290161
1671290161

Rating:
Service parts 101441-9670 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
16600-43G02
12.
Open Pre:MPa(Kqf/cm2)
9.8{100}
15.
NOZZLE SET
Include in #1:
101441-9670
as INJECTION-PUMP ASSEMBLY
Include in #2:
105856-3220
as _
Cross reference number
ZEXEL
101441-9670
1014419670
NISSAN-DIESEL
1671290161
1671290161
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
2.3
2.25
2.35
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
11.4
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
41.6
40.6
42.6
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
7.9+-0.5
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
8
6.9
9.1
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Injection quantity adjustment_03
Adjusting point
C
Rack position
14.7-0.3
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
52
42
62
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
550--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
500
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1500
Advance angle
deg.
3
2.5
3.5
Timer adjustment_04
Pump speed
r/min
1800
Advance angle
deg.
4.5
4
5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment

N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT: RAL
(4)Set idle sub-spring
(5)Main spring setting
(6)Rack difference between N = N1 and N = N2
----------
K=10 RAL=14.7-0.3mm N1=1500r/min N2=500r/min
----------
----------
K=10 RAL=14.7-0.3mm N1=1500r/min N2=500r/min
----------
Speed control lever angle

F:Full speed
I:Idle
(1)Set the pump speed at aa. ( At delivery )
(2)Set the pump speed at bb.
(3)Stopper bolt setting
----------
aa=1800r/min bb=1500r/min
----------
a=32deg+-5deg b=17deg+-5deg c=8deg+-5deg
----------
aa=1800r/min bb=1500r/min
----------
a=32deg+-5deg b=17deg+-5deg c=8deg+-5deg
Stop lever angle

N:Pump normal
S:Stop the pump.
----------
----------
a=12deg+-5deg b=53deg+-5deg
----------
----------
a=12deg+-5deg b=53deg+-5deg
0000001501 GOV FULL LOAD ADJUSTMENT

Title1:Full load stopper adjustment
Title2:Governor set speed
LABEL1:Distinguishing
LABEL2:Pump speed (r/min)
LABEL3:Ave. injection quantity (mm3/st)
LABEL4:Max. var. bet. cyl.
LABEL5:Remarks
LABEL6:Distinguishing
LABEL7:Governor set speed (r/min)
LABEL8:Remarks
(1)Adjustment conditions are the same as those for measuring injection quantity.
(2)-
----------
----------
a1=A a2=- r1=1500r/min r2=- Q1=41.6+-1mm3/st Q2=- c1=+-2.5% c2=- a3=36 a4=30 r3=1800r/min r4=1500r/min
----------
----------
a1=A a2=- r1=1500r/min r2=- Q1=41.6+-1mm3/st Q2=- c1=+-2.5% c2=- a3=36 a4=30 r3=1800r/min r4=1500r/min
Timing setting

(1)Pump vertical direction
(2)Position of gear mark 'ZZ' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=18deg
----------
a=(100deg)
----------
aa=18deg
----------
a=(100deg)
Information:
The RTD Module Status LED
The module status LED indicators are used in order to indicate operating errors or module errors. You can not recover from the module errors. When an error is present, the RTD module no longer communicates to the processor. The channel states are disabled and the data words are cleared.The RTD Module LED Indicators
Illustration 18 g00563392
The "Module Status" LED is on. The "Channel Status" LED is flashing. Refer to Troubleshooting, "Resistance Temperature Detector".
Illustration 19 g00563417
The "Module Status" LED is off. Cycle the power and refer to Troubleshooting, "Resistance Temperature Detector".Modbus Module
The Modbus module allows an Allen-Bradley SLC 500 to interface with devices that are compatible with Modbus. The module allows a remote access to the MMS.Port Information for the Modbus Module
Illustration 20 g00563418
Information for port 1 is in the following list:
RS-485
1 stop bit and no parity
RTU slave
Baud Rate from the "Setup" Screen
Address from the "Setup" ScreenInformation for port 2 is in the following list:
RS-232
1 stop bit and no parity
RTU slave
Baud Rate from the "Setup" Screen
Address from the "Setup" ScreenJumper Settings for the Modbus Module
Illustration 21 g00563421
Troubleshooting the Modbus Module
Illustration 22 g00563423
Table 1
LED Name    Color    Status    Indication    
CFG     Green     Off     The normal state of the LED. No configuration related activity is occurring.    
 
The module status LED indicators are used in order to indicate operating errors or module errors. You can not recover from the module errors. When an error is present, the RTD module no longer communicates to the processor. The channel states are disabled and the data words are cleared.The RTD Module LED Indicators
Illustration 18 g00563392
The "Module Status" LED is on. The "Channel Status" LED is flashing. Refer to Troubleshooting, "Resistance Temperature Detector".
Illustration 19 g00563417
The "Module Status" LED is off. Cycle the power and refer to Troubleshooting, "Resistance Temperature Detector".Modbus Module
The Modbus module allows an Allen-Bradley SLC 500 to interface with devices that are compatible with Modbus. The module allows a remote access to the MMS.Port Information for the Modbus Module
Illustration 20 g00563418
Information for port 1 is in the following list:
RS-485
1 stop bit and no parity
RTU slave
Baud Rate from the "Setup" Screen
Address from the "Setup" ScreenInformation for port 2 is in the following list:
RS-232
1 stop bit and no parity
RTU slave
Baud Rate from the "Setup" Screen
Address from the "Setup" ScreenJumper Settings for the Modbus Module
Illustration 21 g00563421
Troubleshooting the Modbus Module
Illustration 22 g00563423
Table 1
LED Name    Color    Status    Indication    
CFG     Green     Off     The normal state of the LED. No configuration related activity is occurring.