101441-9620 ZEXEL 9 400 619 645 BOSCH INJECTION-PUMP ASSEMBLY 9400619645 1014419620 1679090267


 

Information injection-pump assembly

BOSCH 9 400 619 645 9400619645
ZEXEL 101441-9620 1014419620
NISSAN-DIESEL 1679090267 1679090267
101441-9620 INJECTION-PUMP ASSEMBLY
Rating:
71
Buy INJECTION-PUMP ASSEMBLY 101441-9620 zexel genuine, new aftermarket engine parts with delivery

Service parts 101441-9620 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101044-8080
3. GOVERNOR 105410-9640
4. SUPPLY PUMP 105220-4630
5. AUTOM. ADVANCE MECHANIS 105622-0910
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105141-1800
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 9.8{100}
13. NOZZLE-HOLDER 105071-1240
14. NOZZLE 105000-1010
15. NOZZLE SET

Include in #1:

101441-9620 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

BOSCH 9 400 619 645 9400619645
ZEXEL 101441-9620 1014419620
NISSAN-DIESEL 1679090267 1679090267


Zexel num
Bosch num
Firm num
Name
101441-9620 
9 400 619 645 
1679090267  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
SD25T * K 14BC PE4A,5A, PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   2.3 2.25 2.35
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   11.3
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   43.7 42.7 44.7
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   10.8
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   42.1 40.6 43.6
Max. variation between cylinders %   0 -4 4
Fixing the lever   *
Injection quantity adjustment_03
Adjusting point   -
Rack position   6.8+-0.5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   8 6.9 9.1
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Timer adjustment
Pump speed r/min   500
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   1.8 1.3 2.3
Timer adjustment_03
Pump speed r/min   1150
Advance angle deg.   2.9 2.4 3.4
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   5 5 5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101441-9620
N:Pump speed R:Rack position (mm) (1)Target notch: K
----------
K=14
----------

Speed control lever angle

Test data 101441-9620
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(25deg)+-5deg b=(12deg)+-5deg

Stop lever angle

Test data 101441-9620
N:Pump normal S:Stop the pump.
----------

----------
a=19deg+-5deg b=53deg+-5deg

Timing setting

Test data 101441-9620
(1)Pump vertical direction (2)Position of gear mark 'Y' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=20deg
----------
a=(130deg)




Information:


Illustration 10 g00562677
Long strings of text will crowd the screen. Keep the custom text as short as possible. If the screen is unreadable shorten the text. Touching the "Done" button returns you to the "Language Conversion" screen. Setup of the Communications
The next two windows are for the setup of communications. The screens are for the two Modbus RTU ports. Port 1 is RS-485 and Port 2 is RS-232C.The "Engine Setup (plc-Baud)" window allows a baud rate to be selected for the two ports. The"Engine Setup (plc-Address)" window is used for setting the external address.Note: Refer to sheet 22 of the MMS System Schematics for cable connections and information.Note: Refer to Systems Operation, "Signal Listing". This is a detailed list of all the Modbus output registers.
Illustration 11 g00594475
Illustration 12 g00594478
Auxiliary Options
Illustration 13 g00594454
Note: If your MMS has been customized at time of sale, some of these options may not be available.The user can configure 4 of the system's input. The terminal blocks for 2 RTDS are located in the MECP. The terminal blocks for 2 4-20mA transducers are also located in the MECP. The spare input may be used for any RTD or 4-20mA analog input.Touch the "Auxiliary Options" picture in order to configure the auxiliary input. Touch the "Auxiliary Options" picture in order to configure the auxiliary outputs. You are now on the "MMS Customation" screen."Edit Gauges" Screen
Touch the "Edit Gauges" button. Four auxiliary analog inputs are available. Each input may be added to the MMS display.Two of the inputs are for RTDS. The RTDS are set within a range of 0 °C (32.0 °F) to 150 °C (302.0 °F). The two remaining inputs are 4-20 mA. The inputs must have ranges that can be configured. This provides appropriate scaling for the numerical display. The ranges also provide appropriate scaling for the graphic display.
Illustration 14 g00594484
Auxiliary Temperature Input Setup
Touch the gauge in order to activate the specific "Auxiliary Temperature Gauge". The green check mark indicates that the gauge is activated.
Illustration 15 g00562687
Setup of the Auxiliary Analog Input
Touch the gauge in order to activate the specific "Auxiliary Analog Gauge". The green check mark indicates that the gauge is selected. Touch the "Gauge Range" box. This will display a numeric keypad. Enter the maximum value for the analog input. Touch the "OK" key. The scaling of the analog input start at zero.Touch the "UUU__XXXXXXXXX" box. This will display a keyboard. Type first 3 characters and then type a space. Type the label for the auxiliary analog input. Touch the "Enter" key in order to proceed.Customize the Auxiliary Labels
Note: The external keyboard will be required for this function.A keyboard with a PS/2 connection may be used. Plug the keyboard into the "keyboard" connection on the back of the PC.You are on the "MMS Customization" screen. Touch the "Edit Auxiliary Labels" button.
Illustration 16 g00594490
Labels for the Auxiliary Alarms
Note: The external keyboard will be required for this function. A keyboard with a PS/2 connection may be used. Plug the keyboard into the "keyboard" connection on the back of the PC.Four

Have questions with 101441-9620?





Group cross 101441-9620 ZEXEL

Nissan-Diesel 

 
1670090071 
INJECTION-PUMP ASSEMBLY
TD23
9 400 614 138 
1670090073 
INJECTION-PUMP ASSEMBLY
TD23
9 400 614 139 
1670090074 
INJECTION-PUMP ASSEMBLY
TD23
101441-9620  
9 400 619 645 
1679090267 
INJECTION-PUMP ASSEMBLY
SD25T
F 01G 09U 01K 
1679090272 
INJECTION-PUMP ASSEMBLY
TD23
F 01G 09U 01L 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

9 400 619 982 
1679090276 
INJECTION-PUMP ASSEMBLY
TD23
9 400 619 751 
1679090277 
INJECTION-PUMP ASSEMBLY
TD2304
9 400 614 140 
1679090379 
INJECTION-PUMP ASSEMBLY
TD2304
 
1671290160 
INJECTION-PUMP ASSEMBLY
TD2305
 
1671290172 
INJECTION-PUMP ASSEMBLY
TD2305
9 400 611 741 
1671290200 
INJECTION-PUMP ASSEMBLY
TD2305
 
1671290161 
INJECTION-PUMP ASSEMBLY
TD2305
 
1671290173 
INJECTION-PUMP ASSEMBLY
TD2305
9 400 611 883 
1671290201 
INJECTION-PUMP ASSEMBLY
TD2305
9 400 614 141 
16700T8281 
INJECTION-PUMP ASSEMBLY
SD25
 
 
INJECTION-PUMP ASSEMBLY

Nissan-Diesel 

 
1679090300 
INJECTION-PUMP ASSEMBLY
TD2704
Back to top