101432-4010 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014324010 8971007140


 

Information injection-pump assembly

ZEXEL 101432-4010 1014324010
ISUZU 8971007140 8971007140
101432-4010 INJECTION-PUMP ASSEMBLY
Rating:
71
Buy INJECTION-PUMP ASSEMBLY 101432-4010 zexel genuine, new aftermarket engine parts with delivery

Service parts 101432-4010 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101043-9190
3. GOVERNOR 105419-1430
4. SUPPLY PUMP 105220-4742
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156635-6320
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105151-1451
11. Nozzle and Holder 5-15300-039-1
12. Open Pre:MPa(Kqf/cm2) 11.8{120}
13. NOZZLE-HOLDER 105081-3141
14. NOZZLE 105000-1650
15. NOZZLE SET

Include in #1:

101432-4010 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101432-4010 1014324010
ISUZU 8971007140 8971007140


Zexel num
Bosch num
Firm num
Name
101432-4010 
101432-4011 
 
8971007140  ISUZU
INJECTION-PUMP ASSEMBLY
C240 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   2.25 2.2 2.3
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   12
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   41 40 42
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   7.6+-0.5
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   8 6.9 9.1
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101432-4010
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK CAP: R1
----------
K=11 R1=(17.5)mm
----------

Speed control lever angle

Test data 101432-4010
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=(9deg)+-5deg b=(19deg)+-5deg

Stop lever angle

Test data 101432-4010
N:Pump normal S:Stop the pump. (1)Normal
----------

----------
a=19deg+-5deg b=53deg+-5deg

Timing setting

Test data 101432-4010
(1)Pump vertical direction (2)Gear mark Z for the No. 4 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=18deg
----------
a=(60deg)




Information:


6V7070 Heavy-Duty Digital MultimeterThe 6V7070 Heavy-Duty Digital Multimeter is a completely portable, hand held instrument with a digital display. This multimeter is built with extra protection against damage in field applications, and is equipped with seven functions and 29 ranges. The 6V7070 Multimeter has an instant ohms indicator that permits continuity checking for fast circuit inspection. It also can be used for troubleshooting small value capacitors.The 6V7800 Regular-Duty Digital Multimeter (a low cost option to the Heavy-Duty Multimeter) is also available; however, the 6V7800 Multimeter does not have the 10A range or the instant ohms feature of the 6V7070 Multimeter. Make reference to Special Instruction, Form No. SEHS7734 for complete information for use of the 6V7070 and 6V7800 Multimeters.Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 4C4911 Battery Load Tester to load test a battery that does not hold a charge when in use. Refer to Operating Manual, Form No. SEHS9249 for more detailed instructions on use of the 4C4911 Battery Load Tester. See Special Instruction, Form No. SEHS7633, Battery Test Procedure, for the correct procedure and specifications to use when testing batteries.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.To check for correct output of the alternator, see the Specifications module.For complete service information, refer to Service Manual Module, Form No. SENR3862. This module is part of REG00636 Service Manual.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must

Have questions with 101432-4010?





Group cross 101432-4010 ZEXEL

Isuzu 

9 400 614 116 
8970629690 
INJECTION-PUMP ASSEMBLY
C240
101432-4010  

101432-4011 
 
8971007140 
INJECTION-PUMP ASSEMBLY
C240
9 400 610 503 
8971279990 
INJECTION-PUMP ASSEMBLY
C240
9 400 612 564 
8971488750 
INJECTION-PUMP ASSEMBLY
C240
9 400 614 117 
8971488760 
INJECTION-PUMP ASSEMBLY
C240
Back to top