101402-0350 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014020350 5156012563


 

Information injection-pump assembly

ZEXEL 101402-0350 1014020350
ISUZU 5156012563 5156012563
101402-0350 INJECTION-PUMP ASSEMBLY
Rating:
20
Buy INJECTION-PUMP ASSEMBLY 101402-0350 zexel genuine, new aftermarket engine parts with delivery

Service parts 101402-0350 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-8100
3. GOVERNOR 105410-4040
4. SUPPLY PUMP 105220-4772
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE
7. COUPLING PLATE 156635-3021
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-5792
11. Nozzle and Holder 8-94130-074-3
12. Open Pre:MPa(Kqf/cm2) 14.7{150}
13. NOZZLE-HOLDER 105030-3391
14. NOZZLE 105015-4740
15. NOZZLE SET

Include in #1:

101402-0350 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101402-0350 1014020350
ISUZU 5156012563 5156012563


Zexel num
Bosch num
Firm num
Name
101402-0350 
 
5156012563  ISUZU
INJECTION-PUMP ASSEMBLY
4BB1 * K 14BC PE4A,5A, PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   A
Rack position   9.4
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   53 52 54
Max. variation between cylinders %   0 -2 2
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   7.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   10 8.6 11.4
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 

Test data Ex:

Governor adjustment

Test data 101402-0350
N:Pump speed R:Rack position (mm) (1)Target notch: K
----------
K=16
----------

Speed control lever angle

Test data 101402-0350
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=14deg+-5deg b=20deg+-5deg

Stop lever angle

Test data 101402-0350
N:Pump normal S:Stop the pump.
----------

----------
a=19deg+-5deg b=53deg+-5deg

Timing setting

Test data 101402-0350
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(90deg)




Information:


Illustration 74 g02026337 Appendix D
Cleaned Filter Specification
Note: Scope: The following steps determine a properly cleaned Caterpillar filter.Note: This specification applies to filters that were cleaned of ash only. This specification is only valid subsequent to the "Recommended Cleaning Procedure". This specification should not be used to determine if soot filled filters are properly cleaned. All filters must be baked appropriately using the "Recommended Cleaning Procedure" prior to application of this specification.HEALTH AND SAFETY
Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.
Adhere to all local Health and Safety rules and regulations. Use all the personal protective equipment listed below:
Respirator
Safety shoes
Safety glasses
Latex gloves
Lab coatRESOURCESNecessary equipment:
38 cm (15 inch) long by 0.9 mm (0.04 inch) thick stainless steel probe for "200 cpsi" (Cells/Square inch) filters
Tape measureMETHODEvaluation of a cleaned filter:Note: A filter MUST meet all criteria in this section below to be considered clean.
Inspect both inlet and outlet surfaces for oil/fuel contamination, gouges and/or cracks. No cracks may be visible. Gouges may not be exceed 4.0 mm (0.15 inch) deep.
There must be no filter movement within the filters banding. This movement is defined as the substrate moving past the bent-over flange. The filter must be even or below the bent-over flange.
There must not be any signs of the steel fiber ring coming loose or any mat material (cottony gauze) slipping past the filter. See Illustration 75 below.
The flanges are not damaged beyond repair.
There are no dents deeper than 6.4 mm (0.25 inch) in the outer can of the filter and the outer can is not cracked, torn or otherwise breached.
No more than 20 cells are allowed to be damaged (showing soot) on the outlet face of the filter. Refer to Illustrations 76 and 77.
Inspect the ash depth in the cells using the "Check Cell Depth" instructions below.
Illustration 75 g02026392
Proper placement of the filter within the banding
(1) Outside Can
(2) Bent-over flange
(3) Steel fiber ring
(4) Mat material
(5) FilterNote: Filter must be below the bent over-flange (2).
Illustration 76 g02026398
Acceptable filter with less than 20 damaged cells
Illustration 77 g02026399
Unacceptable filter with too many damaged cells
Check Cell Depth
Check cell depth by dropping the stainless steel probe into a cell location noted by a dot in Illustration 78 below.
Lightly tap the probe with a finger until the probe does not travel into the cell any further. Mark the probe to record the depth.
Illustration 78 g02026405
Measure the distance from the tip of the probe which entered the cell to the mark made on the probe. This distance is the cell depth. Repeat this step 17 times per Illustration 78.
If the probe travels a minimum of 28.6 cm (11.25 inch) in all cells, the filter is considered clean.
If the probe encounters heavy resistance in

Have questions with 101402-0350?





Group cross 101402-0350 ZEXEL

Isuzu 

 
5156011453 
INJECTION-PUMP ASSEMBLY
4BD1
 
5156011973 
INJECTION-PUMP ASSEMBLY
4BD1
 
5891560101 
INJECTION-PUMP ASSEMBLY
UM4BD1T
9 400 613 818 
 
INJECTION-PUMP ASSEMBLY
8PA1
 
5156012541 
INJECTION-PUMP ASSEMBLY
4BD1
 
5156013082 
INJECTION-PUMP ASSEMBLY
4BD1
101402-0350  
 
5156012563 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156012453 
INJECTION-PUMP ASSEMBLY
4BD1
9 400 610 435 
5156012454 
INJECTION-PUMP ASSEMBLY
4BD1
 
5156012463 
INJECTION-PUMP ASSEMBLY
4BD1
 
5156012680 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156012681 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156012682 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156012683 
INJECTION-PUMP ASSEMBLY
4BB1
 
5156012832 
INJECTION-PUMP ASSEMBLY
4BD1
Back to top