101401-9241 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014019241


 

Information injection-pump assembly

ZEXEL 101401-9241 1014019241
101401-9241 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 101401-9241 zexel genuine, new aftermarket engine parts with delivery

Service parts 101401-9241 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-9881
3. GOVERNOR 105921-7190
4. SUPPLY PUMP 105210-6010
5. AUTOM. ADVANCE MECHANIS 105671-0430
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5720
11. Nozzle and Holder TF33 13 H50
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105048-3450
14. NOZZLE 105017-1510
15. NOZZLE SET

Include in #1:

101401-9241 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101401-9241 1014019241


Zexel num
Bosch num
Firm num
Name
101401-9241 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-3420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.5
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   67 66.5 67.5
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   14.5 12.5 16.5
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.5)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   67 66.5 67.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.55
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   81 77 85
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.5
Pump speed r/min   625 625 625
Average injection quantity mm3/st.   47.8 43.8 51.8
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   160 160
Fixing the lever   *
Timer adjustment
Pump speed r/min   1000--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   950
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1625
Advance angle deg.   5 4.5 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-9241
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=J12
----------

Speed control lever angle

Test data 101401-9241
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=36mm
----------
a=20eg+-5deg b=(41deg)+-3deg

Stop lever angle

Test data 101401-9241
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa (2)Set the stop adjuster screw
----------
aa=39mm
----------
a=14deg+-5deg b=(29.5deg)+-5deg

0000001501 LEVER

Test data 101401-9241
CL:Center line of camshaft ST:Stop adjuster screw f1:Direction for pulling the speed lever f2:Direction for pulling the stop lever 1. Stop lever adjustment outline (1)After completing all adjustments, confirm that the lever angle is within the specifications in the normal position. (2)Set the speed lever in the full speed position. (3)At pump speed Na, position the rack at non-injection position Ra. (4)Set the stop adjusting screw to fix the speed lever in the idling position. (5)Confirm that there is no injection at pump speed Nb.
----------
Na=1825r/min Nb=325r/min Ra=4.7+-0.3mm
----------

Timing setting

Test data 101401-9241
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=8deg
----------
a=(140deg)




Information:


20Oct2015
U-557
A-401
D-483
O-483
TM-15
TA-4
Parts stock action only
PRODUCT IMPROVEMENT PROGRAM FOR REMOVING CERTAIN 20R-0476 INJECTOR ASSEMBLIES FROM DEALER PARTS STOCK
7750 PI70592
Caterpillar’s obligations under this Service Letter are subject to, and shall not apply in contravention of, the laws, rules, regulations, directives, ordinances, orders, or statutes of the United States, or of any other applicable jurisdiction, without recourse or liability with respect to Caterpillar.
When submitting claim for Parts Stock Action, Use the appropriate 99Z as the s/n, the appropriate Service Letter Program Number as the Part number in the Part Causing Failure field, "7751" as the Group Number, "56" as the Description Code.
The information supplied in this service letter may not be valid after the termination date of this program.Do not perform the work outlined in this Service Letter after the termination date without first contacting your Caterpillar product analyst.
TERMINATION DATE
31Jan2016
PROBLEM
All 20R-0476 Injector Assemblies in dealer parts stock need to be inspected for the date code. 20R-0476 Injector Assemblies that have a date code of D08M07Y15P47 need to be removed from dealer parts stock. These injector as may have a nozzle assembly marked 2645K015 which is not correct. (Image1 = Incorrect) The correct nozzle assembly should be marked 2645K016. (Image2 = Correct) These two nozzles are not interchangeable.
ACTION REQUIRED
Inspect the date code on all 20R-0476 Injector Assemblies in dealer parts stock. 20R-0476 Injector Assemblies that have a date code of D08M07Y15P47 need to be removed from dealer parts stock.
Image1
Image2
SERVICE CLAIM ALLOWANCES
Submit one claim for all parts removed from dealer parts stock.
PARTS DISPOSITION
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling.

Have questions with 101401-9241?





Group cross 101401-9241 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
101401-9241  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

 
TF3513800F 
INJECTION-PUMP ASSEMBLY
TF
 
TF3513800G 
INJECTION-PUMP ASSEMBLY
TF
 
TF3513800H 
INJECTION-PUMP ASSEMBLY
TF
 
TF3513800J 
INJECTION-PUMP ASSEMBLY
TF
9 400 613 800 
TF3513800K 
INJECTION-PUMP ASSEMBLY
TF
Back to top