101401-4560 ZEXEL 9 400 613 712 BOSCH INJECTION-PUMP ASSEMBLY 9400613712 1014014560 8970903661


 

Information injection-pump assembly

BOSCH 9 400 613 712 9400613712
ZEXEL 101401-4560 1014014560
ISUZU 8970903661 8970903661
101401-4560 INJECTION-PUMP ASSEMBLY
Rating:
13
Buy INJECTION-PUMP ASSEMBLY 101401-4560 zexel genuine, new aftermarket engine parts with delivery

Service parts 101401-4560 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101041-8090
3. GOVERNOR 105931-8683
4. SUPPLY PUMP 105210-6150
5. AUTOM. ADVANCE MECHANIS 105676-5020
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5250
11. Nozzle and Holder
12. Open Pre:MPa(Kqf/cm2) 18.1(185)
13. NOZZLE-HOLDER 105048-3670
14. NOZZLE 105017-1210
15. NOZZLE SET

Include in #1:

101401-4560 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101401-4560 
9 400 613 712 
8970903661  ISUZU
INJECTION-PUMP ASSEMBLY
4HF1 * K




Information:

Proper operation and maintenance are key factors in obtaining the maximum life and economy of the engine. Following the directions in this manual will lower operating costs.The time needed for the engine to reach the normal mode of operation is usually less than the time taken for a walk-around-inspection of the engine.After the engine is started and the cold low idle operation is completed, the engine can be operated at rated speed and low power. The engine will reach normal operating temperature faster when operated at rated speed and low power demand than when idled at no load. Typically the engine should be up to operating temperature in a few minutes.Governors and Actuators
Your engine may be equipped with a:* full-range governor* Woodward PSG Governor* Woodward 1724 Actuator* Woodward 524 Actuator
PSG Actuator
1724/524 ActuatorWoodward Governors/Actuators are usually electrically operated from a control panel. The application is usually an EPG power generator set. On standby gen sets the governor may be set to operate only at Full Load Speed.Change Engine Speed
If equipped with a control panel, a RAISE/LOWER switch or a speed setting potentiometer is used to adjust the operating speed.Starting, Operating and Stopping Engines Equipped with Control Panels
For all information regarding the generator control panel used for starting, operating and stopping the engine, refer to the Engine Protection Devices Generator Set Control Panel topic in this publication or Caterpillar SR4 Generators and Control Panels, SEBU6150. Additional information and programming instructions are provided in the Service Manual for your specific control panel.Mechanical Governors (If Equipped)
Governor Control LeverYour engine may be equipped with a full-range governor. Most other manufacturers' engines have min-max type governors that only govern at high and low idle to prevent the engine from overspeeding or dying. With the min-max governor, the position of the speed lever determines the amount of fuel delivered to the engine.With the full-range governor, the position of the speed lever sets engine speed and helps hold a constant speed independent of load which makes operation easier.The governor control motor is a 24 volt motor which allows for engine speed control from a remote location through a governor RAISE/LOWER switch. This governor control switch is used with the optional EMCP II. Always increase engine speed to high idle before applying load.For information regarding initial checks and adjustments, refer to the Service Manual or contact your Caterpillar dealer.Driven Equipment Without Load
1. Move the governor control lever to half engine speed.2. Interrupted starts put excessive stress on the drive train and waste fuel. To get the driven equipment in motion, engage the clutch smoothly, with no load on the equipment. This should result in a smooth, easy start without increasing the engine speed above low idle or slipping the clutch. For generator sets, move the governor control to high idle (full load) position (1800 rpm for 60 Hz and 1500 rpm for 50 Hz).3. Apply the load and check the gauges and equipment for proper operation. Begin operating the engine at low load. After normal oil pressure

Have questions with 101401-4560?





Group cross 101401-4560 ZEXEL

Isuzu 

9 400 613 706 
8970903721 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 707 
8970903681 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 708 
8970903641 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 709 
8970903701 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903670 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 710 
8970903671 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903620 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 711 
8970903621 
INJECTION-PUMP ASSEMBLY
4HF1
101401-4560  
9 400 613 712 
8970903661 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903531 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 491 
8971140060 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903541 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 713 
8971140070 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903551 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970903552 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 714 
8971140080 
INJECTION-PUMP ASSEMBLY
4HF1
Back to top