101401-4395 ZEXEL 9 400 610 398 BOSCH INJECTION-PUMP ASSEMBLY 9400610398 1014014395 8971295660


 

Information injection-pump assembly

BOSCH 9 400 610 398 9400610398
ZEXEL 101401-4395 1014014395
ISUZU 8971295660 8971295660
101401-4395 INJECTION-PUMP ASSEMBLY
Rating:
63
Buy INJECTION-PUMP ASSEMBLY 101401-4395 zexel genuine, new aftermarket engine parts with delivery

Service parts 101401-4395 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101041-8073
3. GOVERNOR 105931-9563
4. SUPPLY PUMP 105210-6120
5. AUTOM. ADVANCE MECHANIS 105676-8000
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-7164
11. Nozzle and Holder 8-97114-315-1
12. Open Pre:MPa(Kqf/cm2) 17.7{180}/21.6{220}
13. NOZZLE-HOLDER 105048-3832
14. NOZZLE
15. NOZZLE SET 105019-1420

Include in #1:

101401-4395 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101401-4395 
9 400 610 398 
8971295660  ISUZU
INJECTION-PUMP ASSEMBLY
4HE1-T K 14BD INJECTION PUMP ASSY PE4AD PE




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 101401-4395?





Group cross 101401-4395 ZEXEL

Isuzu 

 
8970613930 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8970613931 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8970613933 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971140030 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971197160 
INJECTION-PUMP ASSEMBLY
4HE1-T
101401-4395  
9 400 610 398 
8971295660 
INJECTION-PUMP ASSEMBLY
4HE1-T