101401-4352 ZEXEL 9 400 613 695 BOSCH INJECTION-PUMP ASSEMBLY 9400613695 1014014352 8970758663


 

Information injection-pump assembly

BOSCH 9 400 613 695 9400613695
ZEXEL 101401-4352 1014014352
ISUZU 8970758663 8970758663
101401-4352 INJECTION-PUMP ASSEMBLY
Rating:
49
Buy INJECTION-PUMP ASSEMBLY 101401-4352 zexel genuine, new aftermarket engine parts with delivery

Include in #1:

Cross reference number

Zexel num
Bosch num
Firm num
Name
101401-4352 
101401-4630 
9 400 613 695 
8970758663  ISUZU
INJECTION-PUMP ASSEMBLY
4HF1 * K




Information:


Spray starting fluid only while cranking the engine.
1. Heat the glow plugs (If equipped) for the approximate heating time shown in the STARTING AID CHART. 2. Turn the HEAT-START switch to START position. While cranking, spray starting fluid into the air inlet or air cleaner for approximately 1 second.
Wait at least 2 seconds before spraying starting fluid again.
3. If necessary, repeat the procedure.4. After the engine starts, it may be necessary to return the HEAT-START switch to the HEAT position until the engine runs smoothly.Jacket Water Heater (Attachment)
In very low temperatures, the lubricating oil must be warmed to allow starting. A jacket water heater can maintain the water temperature at approximately 90°F (32°C). The warm water will keep the oil in the upper part of the engine block warm enough to flow when starting.Dipstick Oil Heater
Contact your Caterpillar dealer before installing a dipstick crankcase oil heater.
Generator
Starting Single Unit Operation
1. Make all preliminary engine starting checks.2. Be sure the main or line circuit breaker is open.3. Start the engine and allow it to warm up.4. Close the main circuit breaker.5. Apply the load. Do not try to apply full load in one move, rather apply the load in increments to maintain system frequency at a constant level.Standby Generator Sets
Most standby units are automatic. They start, pickup the load, run and stop without an operator in attendance. Standby units can not change the governor control setting automatically. The throttle must be preset for the proper operation of that unit. Whenever the set is exercised or operated manually, be sure the throttle setting is correct for automatic operation. Check all switches to see they are properly set: Start Selector Switch in AUTOMATIC position and any Emergency Stop Switches in RUN position.Paralleling
Units may be paralleled at no load or paralleled with units under load. To parallel two or more units the following conditions must be met:1. Same phase rotation.2. Same voltage level.3. Same voltage droop.4. Same frequency.5. Voltages must be in phase.The first condition is established by "phased" wiring connections of initial installation.The second and third conditions are usually established by semi-permanent adjustments to the generator controls.The fourth and fifth conditions are under control of the operation in manual paralleling systems (or under automatic control in automatic paralleling systems).To Parallel
1. Start the unit to be paralleled.2. Turn the synchronizer lights on.3. After the engine has run long enough to warm up, bring it up to synchronous speed (the same frequency as the unit on the line). The synchronizing lights will begin to blink.4. Using the governor control, adjust the speed until the lights blink very slowly.5. The lights are off when the voltages of the two units are in phase. At this point, very quickly close the breaker while the lights are out. The frequency of the incoming unit should be slightly greater than the line frequency. This will allow the incoming unit to assume some of the load rather than add to the system load.Load Division
Once two units have been paralleled,

Have questions with 101401-4352?





Group cross 101401-4352 ZEXEL

Isuzu 

 
8970483060 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970483061 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 690 
8970483063 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970488110 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970488111 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 691 
8970488113 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758630 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758631 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 692 
8970758633 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758640 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 035 
8970758641 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 693 
8970758643 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758650 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758651 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 694 
8970758653 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970758660 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 034 
8970758661 
INJECTION-PUMP ASSEMBLY
4HF1
101401-4352  

101401-4630 
9 400 613 695 
8970758663 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970655220 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 313 
8970655221 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 696 
8970655223 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 314 
8970655230 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 315 
8970655231 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 316 
8970655232 
INJECTION-PUMP ASSEMBLY
4HF1
F 019 Z10 098 
8970655233 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 697 
8970655234 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970613930 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8970613931 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8970613933 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971140030 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971197160 
INJECTION-PUMP ASSEMBLY
4HE1-T
9 400 610 398 
8971295660 
INJECTION-PUMP ASSEMBLY
4HE1-T
Back to top