101401-4081 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014014081 8970279961


 

Information injection-pump assembly

ZEXEL 101401-4081 1014014081
ISUZU 8970279961 8970279961
101401-4081 INJECTION-PUMP ASSEMBLY
Rating:
78
Buy INJECTION-PUMP ASSEMBLY 101401-4081 zexel genuine, new aftermarket engine parts with delivery

Service parts 101401-4081 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-8851
3. GOVERNOR 105931-7790
4. SUPPLY PUMP 105210-5160
5. AUTOM. ADVANCE MECHANIS 105676-5001
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-5110
11. Nozzle and Holder 8-94388-787-0
12. Open Pre:MPa(Kqf/cm2) 18.1{185}
13. NOZZLE-HOLDER 105048-3550
14. NOZZLE 105017-1130
15. NOZZLE SET

Include in #1:

101401-4081 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101401-4081 1014014081
ISUZU 8970279961 8970279961


Zexel num
Bosch num
Firm num
Name
101401-4081 
101401-4120 
 
8970279961  ISUZU
INJECTION-PUMP ASSEMBLY
4HF1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8210
Nozzle   105780-0070
Bosch type code   DN12SD12T-1
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   3.9 3.85 3.95
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.8
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   73.9 72.3 75.5
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   8.7 7.4 10
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.8)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   73.9 72.9 74.9
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.4
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   88.1 84.1 92.1
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   80 80 112
Fixing the lever   *
Timer adjustment
Pump speed r/min   1375--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1325
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1575
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-4081
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=F30
----------

Speed control lever angle

Test data 101401-4081
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=41deg+-5deg b=(35deg)+-3deg

Stop lever angle

Test data 101401-4081
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=20deg+-5deg b=29deg+-5deg

0000001501 FICD

Test data 101401-4081
(A) applied negative pressure (B) Screw (c) Nut 1. Set the actuator as described below. (1)Confirm that there is clearance between the actuator lever and the speed lever. (2)Loosen the nut (C). (3)Push in the screw (B). (4)Apply P1 from the actuator (A) part. (5)Pull out the screw (B) slowly. (6)Tighten and fix the nut (C) when pump speed is Na and the rack position is Ra. (7)Torque the nut (C) to T1. (8)Apply P2 several times. (9)Confirm that the actuator functions normally. (10)Confirm that there is a clearance between the actuator lever and the speed lever at that time.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) Na=410r/min Ra=9.55+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L=(2)mm

Timing setting

Test data 101401-4081
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)Stamping position on the A/T outer rim (4)Pump bracket check hole position. (5)At the No 1 cylinder's beginning of injection, align with the projection seen through the bracket's check hole and mark the outside of the A/T. (6)B.T.D.C.: aa
----------
aa=11deg
----------
a=(60deg) b=(85deg)




Information:

This instruction is written for electronic technicians only, and must not be used by service personnel with no training or knowledge of electronics. For repairs that can be done by the Caterpillar Dealer Serviceman, with no knowledge of electronics, see Special Instruction Form SMHS6964 "Using 1P3500 and 2P8280 Injection Timing Groups."As an aid to the technician for troubleshooting the inverter and timing light, the following information is given in this instruction:1. Circuit board illustrations showing the position of each of the components and the test points (T) for using a voltmeter or an oscilloscope.2. Schematics of the electrical circuit so the technician can easily follow the sequence of the circuit.3. Test point values.4. Electrical parts replacement information.5. Timing light calibration procedure.Timing Light
1P3500 And 2P8280 Timing Lights - Electrical Schematic, Test Points And Parts List
Inverter - Electrical Schematic, Test Points And Parts List
There is a two position switch that is marked ADV.-RPM on the side of the 1P3499 Timing Light. When the timing light is in use, operation of the ADV.-RPM switch is as follows:RPM Position
A fuel injection pulse opens the switch in the transducer and starts a positive pulse (TP9) of fixed duration, from the monostable composed of Q2 and Q3. This pulse turns on a transistor switch Q4, allowing current to pass through meter M1, which mechanically averages pulses from an operating engine, and is calibrated to read RPM. Switch S2 grounds the gate of SCR1 to prevent the flash tube from strobing.ADV. Position
A fuel injection pulse again starts a pulse from the monostable. Adjustment of R7, the TIME-ADVANCE control, now determines the pulse duration from the monostable. When R7 is adjusted so that TDC on the damper coincides with the pointer on the block of an operating engine, the monostable pulse duration is exactly the same as the fuel system advance measured in seconds. Transistor switch Q4 again turns on, allowing current to pass through meter M1, causing a meter indicator that is calibrated in degrees of advance instead of seconds.Electrical Calibration Procedure
Before the electrical calibration can be done, the following equipment must be obtained.1) Oscilloscope with triggered sweep. Heath Co. M/N SO-4530 or equivalent.2) Signal generator. Heath M/N SG-72A or equivalent.3) Electronic counter. Data Precision M/N 5740 or equivalent.4) Electronic switch (dealer built).Calibration Procedure
(1) Hold the 1P3499 Timing Light in the same position (about a 45° angle) as if measuring the timing advance on an engine, and check the mechanical meter zero. Make an adjustment to zero if necessary. (2) To remove the protective rubber boot from the flash tube, twist the rubber boot and pull it away from the timing light as shown. (3) Remove the right side (side that has the serial number tag) of the timing light case.(4) Connect the 1P3499 Timing Light to a circuit like the one that follows. This will simulate (be the same as) a fuel flow transducer on an engine that is operating at 2400 RPM. (5) Turn the TIME-ADV. control counterclockwise (CCW) to its minimum

Have questions with 101401-4081?





Group cross 101401-4081 ZEXEL

Isuzu 

 
8970128730 
INJECTION-PUMP ASSEMBLY
4BG1
 
8970128731 
INJECTION-PUMP ASSEMBLY
4BG1
9 400 613 669 
8970128732 
INJECTION-PUMP ASSEMBLY
4BG1
9 400 613 670 
8943102103 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 671 
8970188263 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 672 
8943654353 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 673 
8970186633 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 674 
8970253251 
INJECTION-PUMP ASSEMBLY
4BD1
 
8970279941 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970279951 
INJECTION-PUMP ASSEMBLY
4HF1
101401-4081  

101401-4120 
 
8970279961 
INJECTION-PUMP ASSEMBLY
4HF1
 
8970279971 
INJECTION-PUMP ASSEMBLY
4HF1
Back to top