Information injection-pump assembly
ZEXEL
101401-1660
1014011660
Rating:
Cross reference number
ZEXEL
101401-1660
1014011660
Zexel num
Bosch num
Firm num
Name
101401-1660
INJECTION-PUMP ASSEMBLY
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-8820
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-3-4-2
Pre-stroke
mm
3.2
3.15
3.25
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-3 deg. 90 89.5 90.5
Cal 1-3 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cyl.1-2 deg. 270 269.5 270.5
Cyl.1-2 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
-
Rack position
11.9
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
73.9
72.3
75.5
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
H
Rack position
9.5+-0.5
Pump speed
r/min
325
325
325
Average injection quantity
mm3/st.
11.2
9.9
12.5
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(11.9)
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
73.9
72.9
74.9
Basic
*
Fixing the lever
*
Boost pressure
kPa
24.7
24.7
Boost pressure
mmHg
185
185
Injection quantity adjustment_04
Adjusting point
B
Rack position
R1+1.9
Pump speed
r/min
1600
1600
1600
Average injection quantity
mm3/st.
94.8
90.8
98.8
Fixing the lever
*
Boost pressure
kPa
24.7
24.7
Boost pressure
mmHg
185
185
Injection quantity adjustment_05
Adjusting point
C
Rack position
(R1-1)
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
46.3
42.3
50.3
Fixing the lever
*
Boost pressure
kPa
24.7
24.7
Boost pressure
mmHg
185
185
Injection quantity adjustment_06
Adjusting point
D
Rack position
R2-0.65
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
18.7
14.7
22.7
Fixing the lever
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Boost compensator adjustment
Pump speed
r/min
300
300
300
Rack position
R2-0.65
Boost pressure
kPa
4
2.7
5.3
Boost pressure
mmHg
30
20
40
Boost compensator adjustment_02
Pump speed
r/min
300
300
300
Rack position
R2(R1-0.
65)
Boost pressure
kPa
11.3
11.3
11.3
Boost pressure
mmHg
85
85
85
Timer adjustment
Pump speed
r/min
1250--
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
1200
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
1600
Advance angle
deg.
4.5
4
5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Torque cam stamping: T1
(2)Tolerance for racks not indicated: +-0.05mm.
(3)Boost compensator stroke: BCL
----------
T1=H62 BCL=0.65+-0.1mm
----------
----------
T1=H62 BCL=0.65+-0.1mm
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Use the hole at R = aa
(2)Stopper bolt set position 'H'
----------
aa=40mm
----------
a=26deg+-5deg b=40deg+-3deg
----------
aa=40mm
----------
a=26deg+-5deg b=40deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Use the hole at R = aa
----------
aa=40mm
----------
a=33deg+-5deg b=40deg+-5deg
----------
aa=40mm
----------
a=33deg+-5deg b=40deg+-5deg
0000001501 MICRO SWITCH
Adjustment of the micro-switch
Adjust the bolt to obtain the following lever position when the micro-switch is ON.
(1)Speed N1
(2)Rack position Ra
----------
N1=1025r/min Ra=8.5+-0.1mm
----------
----------
N1=1025r/min Ra=8.5+-0.1mm
----------
Timing setting
(1)Pump vertical direction
(2)Position of gear mark '3' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=12deg
----------
a=(130deg)
----------
aa=12deg
----------
a=(130deg)
Information:
4. Install a new seal washer (6).Use 6V-4979 Carbon Stop Seal Tool (4) to install new carbon dam (5) on nozzle (2).7000 Series Nozzles
The part number for compression seal (3) is not the same for all nozzles. If the correct seal is not installed, the result will be high emissions. This is NOT acceptable.
Troubleshooting (Pencil-Type Fuel Nozzles Only)
A. To troubleshoot these nozzles, refer to the Troubleshooting Guide For Pencil-Type Fuel Nozzles located in this manual.B. Refer to Special Instruction SEHS8627 "Use of 8S-2245 Nozzle Cleaning Tool Group" for the correct procedure (according to the part number of the nozzle) in order to clean these nozzles. C. If VO is LESS than the specified value for a specific part number, DO NOT use the nozzle.Troubleshooting Guide For Pencil-Type Fuel Nozzles
Troubleshooting Guide For Caterpillar 7000 Series Direct Injection Fuel Nozzles
Engine Nozzle Test Record Form (Sample Copy)
Repair/Calibration Information For 5P-4150 Tester Group
For the repair and/or calibration of the 5P-4150 Tester Group, contact the manufacturer: U.S. Mail:OTC Division
SPX Corporation
655 Eisenhower Drive
Owatonna, Minnesota 55060, U.S.A.
Telephone:(507) 455-7000(800) 533-6127 Fax:(800) 955-8329Test Equipment Calibration
Caterpillar fuel nozzle and unit injector testers feature premium quality, liquid filled gauges for high accuracy and durability.Pressure gauges, in this application must be of high quality in order to provide accurate and consistent test results.To maintain this high degree of accuracy, gauge calibration should be checked at a MINIMUM of once a year. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester". However, calibration should be checked at any time when the test results have become INCONSISTENT or if the gauge needle does NOT return to the 0 (zero) range when the test pressure is relieved.Calibration
Two methods are available for gauge calibration:* Method 1: Calibration by gauge manufacturer.* Method 2: 5P-8558 Pressure Gauge Calibrating Group. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester".Calibration By Gauge Manufacturer (Method 1)
Certified calibration services are offered by Carrier - Oehler Company, a Caterpillar certified supplier of premium quality gauges.The Carrier - Oehler Company can promptly check and recalibrate gauges at a low cost.The Carrier - Oehler Company will also repair and recalibrate damaged gauges at a fraction of the cost of a new gauge.When sending gauges to Carrier - Oehler Company, include the following information:* Person or department that gauges and/or correspondence is to be directed to.* List the quantity and a brief description of the gauge(s) problem or the service requested.* Dealer name and address.* Telephone number.* Fax number. The Carrier - Oehler Company will advise you if repair costs exceed 50 percent of a new gauge. Questions on costs, service, and repair time should be directed to the Caterpillar Repair Desk:(800) 321-3241 Shipping:Carrier - Oehler Company
16965 Vincennes Avenue
South Holland, Illinois 60473
U.S. Mail:Carrier - Oehler Company
Post Office Box 40
16965 Vincennes Avenue
South Holland, Illinois 60473
Telephone:(708) 339-8200 Fax:(708) 339-98305P-8558 Pressure Gauge Calibrating Group (Method 2)
(1) 5P-0946 Box Assembly.(2) 1P-2375 Quick
The part number for compression seal (3) is not the same for all nozzles. If the correct seal is not installed, the result will be high emissions. This is NOT acceptable.
Troubleshooting (Pencil-Type Fuel Nozzles Only)
A. To troubleshoot these nozzles, refer to the Troubleshooting Guide For Pencil-Type Fuel Nozzles located in this manual.B. Refer to Special Instruction SEHS8627 "Use of 8S-2245 Nozzle Cleaning Tool Group" for the correct procedure (according to the part number of the nozzle) in order to clean these nozzles. C. If VO is LESS than the specified value for a specific part number, DO NOT use the nozzle.Troubleshooting Guide For Pencil-Type Fuel Nozzles
Troubleshooting Guide For Caterpillar 7000 Series Direct Injection Fuel Nozzles
Engine Nozzle Test Record Form (Sample Copy)
Repair/Calibration Information For 5P-4150 Tester Group
For the repair and/or calibration of the 5P-4150 Tester Group, contact the manufacturer: U.S. Mail:OTC Division
SPX Corporation
655 Eisenhower Drive
Owatonna, Minnesota 55060, U.S.A.
Telephone:(507) 455-7000(800) 533-6127 Fax:(800) 955-8329Test Equipment Calibration
Caterpillar fuel nozzle and unit injector testers feature premium quality, liquid filled gauges for high accuracy and durability.Pressure gauges, in this application must be of high quality in order to provide accurate and consistent test results.To maintain this high degree of accuracy, gauge calibration should be checked at a MINIMUM of once a year. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester". However, calibration should be checked at any time when the test results have become INCONSISTENT or if the gauge needle does NOT return to the 0 (zero) range when the test pressure is relieved.Calibration
Two methods are available for gauge calibration:* Method 1: Calibration by gauge manufacturer.* Method 2: 5P-8558 Pressure Gauge Calibrating Group. Additional information can be found in NEHS0631 "General Maintenance And Troubleshooting For Fuel Injection Equipment Test Stands (FIETS) And 5P-4150 Nozzle Tester".Calibration By Gauge Manufacturer (Method 1)
Certified calibration services are offered by Carrier - Oehler Company, a Caterpillar certified supplier of premium quality gauges.The Carrier - Oehler Company can promptly check and recalibrate gauges at a low cost.The Carrier - Oehler Company will also repair and recalibrate damaged gauges at a fraction of the cost of a new gauge.When sending gauges to Carrier - Oehler Company, include the following information:* Person or department that gauges and/or correspondence is to be directed to.* List the quantity and a brief description of the gauge(s) problem or the service requested.* Dealer name and address.* Telephone number.* Fax number. The Carrier - Oehler Company will advise you if repair costs exceed 50 percent of a new gauge. Questions on costs, service, and repair time should be directed to the Caterpillar Repair Desk:(800) 321-3241 Shipping:Carrier - Oehler Company
16965 Vincennes Avenue
South Holland, Illinois 60473
U.S. Mail:Carrier - Oehler Company
Post Office Box 40
16965 Vincennes Avenue
South Holland, Illinois 60473
Telephone:(708) 339-8200 Fax:(708) 339-98305P-8558 Pressure Gauge Calibrating Group (Method 2)
(1) 5P-0946 Box Assembly.(2) 1P-2375 Quick
Have questions with 101401-1660?
Group cross 101401-1660 ZEXEL
101401-1660
INJECTION-PUMP ASSEMBLY