101401-1103 ZEXEL 9 400 610 392 BOSCH INJECTION-PUMP ASSEMBLY 9400610392 1014011103 me016323


 

Information injection-pump assembly

BOSCH 9 400 610 392 9400610392
ZEXEL 101401-1103 1014011103
MITSUBISHI ME016323 me016323
101401-1103 INJECTION-PUMP ASSEMBLY
Rating:
24
Buy INJECTION-PUMP ASSEMBLY 101401-1103 zexel genuine, new aftermarket engine parts with delivery

Service parts 101401-1103 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-9320
3. GOVERNOR 105921-1743
4. SUPPLY PUMP 105220-5150
5. AUTOM. ADVANCE MECHANIS 105676-0210
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105118-4120
11. Nozzle and Holder ME017801
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105048-3070
14. NOZZLE 105017-0100
15. NOZZLE SET

Include in #1:

101401-1103 as INJECTION-PUMP ASSEMBLY

Cross reference number

Zexel num
Bosch num
Firm num
Name
101401-1103 
9 400 610 392 
ME016323  MITSUBISHI
INJECTION-PUMP ASSEMBLY
4D31T * K




Information:

Starting System
Use a D.C. voltmeter to locate starting system components which do not function.Move starting control switch to energize the starter solenoid. Starter solenoid operation is audible as the starter motor pinion engages with the ring gear on the engine flywheel. The solenoid operation should also close the electric circuit to the motor. Attach one voltmeter lead to the solenoid terminal that is connected to the motor. Ground the other lead. Energize the starter solenoid and observe the voltmeter. A battery voltage reading indicates the malfunction is in the motor. It must be removed for further testing. No voltmeter reading indicates that the solenoid contacts do not close and the solenoid must be repaired or the starter pinion clearance should be adjusted.A starting motor solenoid that will not operate may not be receiving battery current. Attach one lead of the voltmeter to the solenoid battery cable connection. Ground the other lead. No voltmeter reading indicates a faulty circuit from the battery. A voltmeter reading indicates further testing is necessary.Continue the test by attaching one voltmeter lead to the starting motor solenoid small wire terminal and the other lead to ground. Observe the voltmeter and energize the starter solenoid. A voltmeter reading indicates that the malfunction is in the solenoid. No voltmeter reading indicates the starter switch or wiring is the fault.Attach one lead of the voltmeter to the starter switch battery wire terminal and ground the other lead. A voltmeter reading indicates a defective switch.A starting motor that operates too slow can be overloaded by excessive mechanical friction within the engine being started. Slow starting motor operation can also be caused by shorts, loose connections and/or excessive dirt within the motor.Pinion Clearance Adjustment (Prestolite)
There are two adjustments on this type motor. Armature end play and pinion position.Armature End Play
Adjust the end play to .005 to .030 in. (0.13 to 0.76 mm) by adding or removing thrust washers on the commutator end of the armature shaft.Pinion Position
This adjustment is accomplished in two steps.1. To adjust the pinion distance, connect the solenoid to a 12 volt battery as shown.Momentarily flash the jumper lead from the motor terminal stud of the solenoid to the terminal stud at (1) in the commutator end head to shift the solenoid and drive into the cranking position.
CONNECTIONS FOR ADJUSTING THE PINION POSITION
1. Jumper lead flashing point.Remove the jumper lead. The drive will remain in the cranking position until the battery is disconnected.Push the drive toward the commutator end of the motor to eliminate any slack movement in the linkage and measure the distance between the outside edge of the drive sleeve and the thrust washer. The distance (3) must be .02 to .05 in. (0.5 to 1.3 mm).Adjust to this dimension by turning the adjusting nut (2) in or out as required.
PINION POSITION ADJUSTMENT
2. Adjusting nut. 3. Distance.2. To test assembly of solenoid, it will be necessary to have an interference block cut to the dimensions shown.
INTERFERENCE BLOCK DIMENSIONSConnect the solenoid to 24 volts as

Have questions with 101401-1103?





Group cross 101401-1103 ZEXEL

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
101401-1103  
9 400 610 392 
ME016323 
INJECTION-PUMP ASSEMBLY
4D31T

Mitsubishi-Heav 

 
4262400900 
INJECTION-PUMP ASSEMBLY
S4MB

Mitsubishi 

 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 056 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 188 
ME016321 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016234 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016310 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 610 057 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 599 
ME016341 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016235 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
ME016236 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 600 
ME016327 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
 
 
INJECTION-PUMP ASSEMBLY
4D31T
9 400 613 601 
ME016450 
INJECTION-PUMP ASSEMBLY
4D31T
Back to top