105015-6400 ZEXEL 9 432 610 254 BOSCH HOLE-TYPE NOZZLE 9432610254 1050156400


 

Information hole-type nozzle

BOSCH 9 432 610 254 9432610254
ZEXEL 105015-6400 1050156400
105015-6400 HOLE-TYPE NOZZLE
Rating:
15
Buy HOLE-TYPE NOZZLE 105015-6400 zexel genuine, new aftermarket engine parts with delivery

You can express buy:

USD 57
28-04-2025
10 pcs/lot Diesel injector nozzle 105015-6400 DLLA154SN640 for 6102(6BD1) OHMS016
USD 50
11-11-2022
US $5.00
05-01-2017
105015-6400 High quality diesel fuel Injector nozzle DLLA154SN640
Images:
US $5.00
105015-6400 High quality diesel fuel Injector nozzle DLLA154SN640
[09-Dec-2016]
US $5.00
105015-6400 High quality diesel fuel Injector nozzle DLLA154SN640
[05-Dec-2016]
US $5.00
105015-6400 High quality diesel fuel Injector nozzle DLLA154SN640
[26-Apr-2017]

Cross reference number

Zexel num
Bosch num
Firm num
Name
105015-6400 
9 432 610 254 
NP-DLLA154SN640 
   
HOLE-TYPE NOZZLE
C 50LC NOZZLE N (DLL-S) N




Information:

Jacket Water Pump
A failed water pump might cause severe engine overheating problems that could result in cracks in the cylinder head, a piston seizure or other potential damage to the engine.Visually inspect the water pump for leaks. If leaking is observed, replace all seals. Refer to the Service Manual for the procedure to replace the seals.Turbocharger
Refer to the Turbocharger topic in the Every 3000 Hours maintenance interval for information regarding turbocharger inspection. Refer to the Service Manual, or consult with your Caterpillar dealer for the complete turbocharger inspection procedure.Alternator and Starting Motor
Caterpillar recommends a scheduled inspection of the alternator. Inspect the alternator for loose connections and proper battery charging. Inspect the ammeter gauge during engine operation to ensure the batteries and/or electrical system is performing correctly. Make repairs as necessary. Refer to the Service Manual.Check the alternator and battery charger for proper operation. If the batteries are properly charged, ammeter reading should be very near zero. All batteries should be kept charged. The batteries should be kept warm because temperature affects the cranking power. If the battery is too cold, it will not crank the engine, even if the engine is warm.When the engine is not run for long periods of time or run for short periods, the batteries may not fully recharge. Ensure the alternator performs properly to charge the battery and to help prevent the battery from freezing.If the starting motor fails, the engine may not start in an emergency situation. Caterpillar recommends a schedule inspection/check of your starting motor. The starting motor should be checked for correct operation. All electrical connections should be cleaned and checked. Refer to the established procedure for inspection and specifications in the Service Manual, or contact your Caterpillar dealer for assistance.Repair Before Failure
Until recently, engine maintenance and repair management involved changing the oil when it was convenient and repairing the engine when it was damaged. This seemed to be the accepted way of managing a maintenance operation.However, due to a variety of circumstances, increasing competition have caused users to look for ways to prolong equipment life and lower operating costs so that they could be competitive.To assist Caterpillar engine users in prolonging engine life and reducing operating costs, the Value Planned Repair approach to engine maintenance was developed.The Value Planned Repair approach can be tailored for any engine. This approach, when properly structured, outlines every maintenance and repair service required to support an engine from the day it enters service until the day it is retired.To ensure the repair is performed efficiently and expediently, the Value Planned Repair concept approaches a given repair in three basis steps:1. Repair determination2. Evaluation of repair options3. Selection of the most appropriate optionThe Value Planned Repair approach addresses:* Services required to maintain an engine at optimum efficiency.* Scheduled maintenance, repairs and overhauls to minimize unscheduled downtime.* Preplanned repairs and overhauls that can be flat-rated, putting you in charge of costs.* Repair

Have questions with 105015-6400?





Group cross 105015-6400 ZEXEL

105015-6400  
9 432 610 254 
NP-DLLA154SN640 
 
HOLE-TYPE NOZZLE

Isuzu 

9 432 610 823 
NP-DLLA154SN641 
1153111570 
NOZZLE
9 432 612 334 
NP-DLLA144SN642 
 
NOZZLE

Isuzu 

9 432 610 908 
NP-DLLA154SN643 
1153111580 
NOZZLE

Mitsubishi 

9 432 610 252 
NP-DLLA160SN644 
ME705446 
NOZZLE

Nissan-Diesel 

9 432 610 406 
NP-DLLA152SN645 
1662097015 
NOZZLE
9 432 612 335 
NP-DLLA103SN646 
 
NOZZLE

Komatsu 

9 432 610 206 
NP-DLL160SN647 
6162133521 
NOZZLE

Nissan-Diesel 

9 432 611 786 
NP-DLLA144SN648 
1662090005 
NOZZLE

Nissan 

9 432 610 213 
NP-DLLA144SN649 
16620T9302 
NOZZLE

Nissan-Diesel 

9 432 610 213 
NP-DLLA144SN649 
16620T9302 
NOZZLE
Back to top