152200-6920 ZEXEL 9 441 610 305 BOSCH HAND PRIMER 9441610305 1522006920 225601860a


 

Information hand primer

BOSCH 9 441 610 305 9441610305
ZEXEL 152200-6920 1522006920
HINO 225601860A 225601860a
152200-6920 HAND PRIMER
Rating:
12
Buy HAND PRIMER 152200-6920 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 152209-0300 CYLINDER
2. [2] 152119-1320 VALVE BODY
2. [2] 152119-1320 VALVE BODY
3. [1] 152123-0000 BUSHING
4. [1] 152310-1000 ADAPTOR
5. [1] 029632-0030 O-RING
6. [1] 029631-6060 O-RING
7. [1] 029341-4070 GASKET
8. [1] 152200-5420 HAND PRIMER
9. [1] 029731-4680 EYE BOLT
10. [4] 139514-0300 GASKET
10. [4] 139514-0300 GASKET
12. [1] 152300-3620 EYE BOLT

Include in #1:

Cross reference number

Zexel num
Bosch num
Firm num
Name
152200-6920 
152200-6921 
9 441 610 305 
225601860A  HINO
HAND PRIMER
* K 14GD PRIMING PUMP F/P
152200-6920 
152200-6921 
9 441 610 305 
22505E0010  HINO
HAND PRIMER
A * K 14GD PRIMING PUMP F/P
152200-6920 
152200-6921 
9 441 610 305 
S225601860  HINO
HAND PRIMER
B * K 14GD PRIMING PUMP F/P
152200-6920 
152200-6921 
9 441 610 305 
S225601860A  HINO
HAND PRIMER
C * K 14GD PRIMING PUMP F/P




Information:


Table 2
Specifications for Pressure Loss
Direct Injection Fuel Systems    
Nozzle pressure must not drop below a gauge reading of
3450 kPa (500 psi) during a 5 second time interval.    
Nozzle pressure must drop below a gauge reading of
1380 kPa (200 psi) after an additional 25 second time interval. (1)    
( 1 ) A gauge reading of 0 kPa (0 psi) is acceptable after the first 5 second time interval has elapsed.
Illustration 3 g00923167
If the fuel nozzle is not within specifications, stop the test and do not use the fuel nozzle.Valve Opening Pressure Test
Slowly increase the pressure until fluid begins to flow from the tip of the fuel nozzle. Record this pressure as the VOP of the fuel nozzle.
Compare the test results to the specifications for the type of fuel nozzle that is being tested. Refer to Table 3, or Table 4.For precombustion chamber fuel systems, use these specifications:
Table 3
Specifications for Valve Opening Pressure
Precombustion Chamber Fuel Systems    
2760 to 5170 kPa (400 to 750 psi)    
Illustration 4 g00934108
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.For direct injection fuel systems, use these specifications:
Table 4
Specifications for Valve Opening Pressure
Direct Injection Fuel Systems    
16500 to 21400 kPa (2400 to 3100 psi)    
Illustration 5 g00923174
If the VOP is not within specifications, stop the test and do not use the fuel nozzle.Tip Leakage Test (Direct Injection Fuel Systems)
Note: Fuel nozzles for precombustion chamber fuel systems can not be tested for tip leakage accurately. Do not perform this test on fuel nozzles for a precombustion

Have questions with 152200-6920?





Group cross 152200-6920 ZEXEL

Hino 

152200-6920  

152200-6921 
9 441 610 305 
225601860A 
HAND PRIMER
152200-6920  

152200-6921 
9 441 610 305 
22505E0010 
HAND PRIMER
152200-6920  

152200-6921 
9 441 610 305 
S225601860 
HAND PRIMER
152200-6920  

152200-6921 
9 441 610 305 
S225601860A 
HAND PRIMER
F 01G 19U 00C 
22505E0010 
HAND PRIMER
Back to top