Information governor
BOSCH
9 420 614 537
9420614537
ZEXEL
105932-1852
1059321852
ISUZU
8971429882
8971429882

Rating:
Scheme ###:
1. | [1] | 159200-7120 | GOVERNOR HOUSING |
2. | [1] | 154007-0200 | ADAPTOR |
3. | [1] | 020018-1840 | BLEEDER SCREW M8P1.25L18 |
4. | [1] | 159232-1600 | PLATE |
5. | [5] | 029010-6810 | BLEEDER SCREW |
5B. | [1] | 020106-1640 | BLEEDER SCREW M6P1.0L14 |
6. | [1] | 159242-0600 | BUSHING |
7. | [1] | 139710-0200 | O-RING |
8. | [1] | 159205-2321 | LEVER SHAFT |
9. | [1] | 159202-7800 | CONTROL LEVER |
10. | [1] | 016010-0810 | LOCKING WASHER |
11/1. | [0] | 029311-0220 | SHIM D18&10.3T0.2 |
11/1. | [0] | 029311-0230 | SHIM D18&10.3T0.5 |
11/1. | [0] | 029311-0430 | SHIM D18&10.3T0.30 |
11/1. | [0] | 029311-0440 | SHIM D18&10.3T0.40 |
11/1. | [0] | 029311-0450 | SHIM D18&10.3T0.25 |
11/1. | [0] | 029311-0460 | SHIM D18&10.3T0.35 |
11/1. | [0] | 139410-3300 | SHIM D18&10.3T0.6 |
11/1. | [0] | 139410-3400 | SHIM D18&10.3T0.8 |
11/1. | [0] | 139410-3500 | SHIM D18&10.3T0.9 |
12. | [1] | 159215-0000 | COILED SPRING |
13. | [1] | 159242-6601 | CONTROL LEVER |
15. | [1] | 013020-8040 | UNION NUT M8P1.25H7 |
16. | [1] | 159237-5500 | CAPSULE |
17. | [1] | 159202-5320 | CONTROL LEVER |
18. | [1] | 159215-0300 | COILED SPRING |
20. | [1] | 159291-0620 | CONTROL LEVER |
22. | [1] | 139610-0700 | PACKING RING |
23/1. | [0] | 139410-3800 | SHIM D22&10.2T0.2 |
23/1. | [0] | 139410-3900 | SHIM D22&10.2T0.3 |
23/1. | [0] | 139410-4000 | SHIM D22&10.2T0.4 |
23/1. | [0] | 139410-4100 | SHIM D22&10.2T0.6 |
23/1. | [0] | 139410-4200 | SHIM D22&10.2T0.8 |
24. | [1] | 159215-4200 | COILED SPRING |
25. | [1] | 159235-5800 | CAP |
26. | [1] | 159290-3021 | CONTROL LEVER |
27. | [1] | 020006-1240 | BLEEDER SCREW M6P1L12 4T |
35. | [1] | 159255-2020 | GOVERNOR COVER |
35/1. | [1] | 159301-6420 | GOVERNOR COVER |
35/2. | [1] | 159205-0400 | LEVER SHAFT |
35/3. | [2] | 159237-0200 | CAPSULE |
35/3. | [2] | 159237-0200 | CAPSULE |
35/4. | [1] | 159253-2720 | TENSIONING LEVER |
35/4/2. | [1] | 159204-6022 | RACK |
35/4/3. | [1] | 159233-0300 | UNION NUT |
35/4/4. | [1] | 159234-0300 | FLAT-HEAD SCREW |
35/4/5. | [1] | 159216-0000 | COILED SPRING |
35/4/6. | [1] | 159216-0100 | COILED SPRING |
35/4/7. | [1] | 159216-0700 | COILED SPRING |
35/5. | [1] | 159203-6120 | GUIDE LEVER |
35/7. | [1] | 159215-1701 | COILED SPRING |
35/8. | [1] | 159231-1300 | BEARING PIN |
35/9. | [2] | 016010-0610 | LOCKING WASHER |
35/10. | [1] | 159238-2900 | BUSHING |
51. | [7] | 020106-3840 | BLEEDER SCREW |
65. | [1] | 155404-5700 | CAP |
100. | [1] | 154101-0420 | FLYWEIGHT ASSEMBLY |
101. | [1] | 025803-1610 | WOODRUFF KEY |
102. | [1] | 029321-2020 | LOCKING WASHER |
103. | [1] | 029231-2030 | UNION NUT |
110. | [1] | 154123-2320 | SLIDING PIECE |
111/1. | [0] | 029311-0010 | SHIM D14&10.1T0.2 |
111/1. | [0] | 029311-0180 | SHIM D14&10.1T0.3 |
111/1. | [0] | 029311-0190 | SHIM D14&10.1T0.40 |
111/1. | [0] | 029311-0210 | SHIM D14&10.1T1 |
111/1. | [0] | 139410-0000 | SHIM D14.0&10.1T0.5 |
111/1. | [0] | 139410-0100 | SHIM D14.0&10.1T1.5 |
111/1. | [0] | 139410-3000 | SHIM D14&10.1T2.0 |
111/1. | [0] | 139410-3100 | SHIM D14&10.1T3.0 |
111/1. | [0] | 139410-3200 | SHIM D14&10.1T4.0 |
112. | [1] | 159236-0200 | TERMINAL STUD |
130. | [1] | 159210-1800 | GOVERNOR SPRING |
131. | [1] | 159211-3700 | GOVERNOR SPRING |
132. | [1] | 159214-0200 | COILED SPRING |
133. | [1] | 159212-8220 | SPRING PACK |
133/1. | [1] | 159234-5602 | GUIDE SLEEVE |
133/2. | [1] | 159212-5000 | COILED SPRING |
133/3. | [1] | 159212-5700 | COILED SPRING |
133/4/1. | [0] | 029310-9240 | SHIM D11.9&9T0.1 |
133/4/1. | [0] | 029310-9250 | SHIM D11.9&9T0.2 |
133/4/1. | [0] | 029310-9260 | SHIM D11.9&9T0.25 |
133/4/1. | [0] | 029310-9270 | SHIM D11.9&9T1.0 |
133/4/1. | [0] | 139409-0100 | SHIM D11.9&9T0.3 |
133/4/1. | [0] | 139409-0200 | SHIM D11.9&9T0.5 |
133/4/1. | [0] | 139409-0300 | SHIM D11.5&9T0.8 |
135. | [1] | 159248-2700 | FLAT-HEAD SCREW |
137. | [1] | 159237-5300 | CAPSULE |
140. | [1] | 159205-2101 | LEVER SHAFT |
145. | [1] | 159233-5700 | UNION NUT |
149. | [1] | 159237-5400 | CAPSULE |
150. | [1] | 159235-5300 | SLOTTED WASHER |
155. | [1] | 159204-7420 | STRAP |
156. | [1] | 159233-0620 | BLEEDER SCREW |
158. | [1] | 013020-5240 | UNION NUT M5P0.8H4 |
160. | [1] | 159252-2221 | LEVER GROUP |
160/1. | [1] | 159205-3711 | LEVER SHAFT |
160/2. | [1] | 159202-4810 | CONTROL LEVER |
160/3. | [1] | 029310-6030 | SHIM D11.5&6.2T0.2 |
160/4. | [1] | 159202-4520 | CONTROL LEVER |
160/5. | [1] | 159202-2200 | CONTROL LEVER |
160/6. | [1] | 159215-2301 | COILED SPRING |
160/7. | [1] | 159215-3900 | COILED SPRING |
160/8. | [1] | 016010-0810 | LOCKING WASHER |
160/9. | [1] | 014020-6140 | PLAIN WASHER |
160/10. | [1] | 016010-0610 | LOCKING WASHER |
160/11. | [1] | 016010-0810 | LOCKING WASHER |
168/1. | [0] | 029311-0640 | SHIM D26.0&10.2T0.95 |
168/1. | [0] | 029311-0650 | SHIM D26.0&10.2T0.20 |
168/1. | [0] | 029311-0660 | SHIM D26.0&10.2T0.25 |
168/1. | [0] | 029311-0670 | SHIM D26.0&10.2T0.30 |
168/1. | [0] | 029311-0680 | SHIM D26.0&10.2T0.35 |
168/1. | [0] | 029311-0690 | SHIM D26.0&10.2T0.40 |
168/1. | [0] | 029311-0700 | SHIM D26.0&10.2T0.50 |
168/1. | [0] | 139410-1400 | SHIM D26&10.2T0.7 |
168/1. | [0] | 139410-1500 | SHIM D26&10.2T0.9 |
168/1. | [0] | 139410-1600 | SHIM D26&10.2T0.8 |
168/1. | [0] | 139410-2700 | SHIM D26&10.2T0.6 |
169. | [1] | 159238-4300 | SHIM |
170. | [1] | 159263-4421 | CONTROL LEVER |
172. | [1] | 013020-8040 | UNION NUT M8P1.25H7 |
173/1. | [1] | 139006-3500 | BLEEDER SCREW M6P1.0L33 |
173/1. | [1] | 139006-3700 | BLEEDER SCREW M6P1.0L34 |
173/1. | [1] | 139006-3800 | BLEEDER SCREW M6P1.0L35 |
173/1. | [1] | 139006-3900 | BLEEDER SCREW M6P1.0L36 |
173/1. | [1] | 139006-5300 | BLEEDER SCREW M6P1.0L31 |
173/1. | [1] | 139006-5400 | BLEEDER SCREW M6P1.0L32 |
173/1. | [1] | 155615-2500 | BLEEDER SCREW M6P1.0L37 |
174. | [1] | 154010-7200 | BLEEDER SCREW M8P1.25L62 |
174B. | [1] | 154010-8100 | BLEEDER SCREW M8P1.25L65 |
175. | [1] | 154010-8100 | BLEEDER SCREW M8P1.25L65 |
176. | [1] | 159225-8600 | UNION NUT |
177. | [1] | 154011-2300 | UNION NUT |
178. | [1] | 154011-2800 | UNION NUT |
236. | [1] | 154390-0000 | GASKET |
237. | [1] | 159238-3100 | GASKET |
250. | [1] | 159229-7320 | BRACKET |
251. | [2] | 154317-8800 | COILED SPRING |
252. | [1] | 020118-1640 | BLEEDER SCREW |
253. | [1] | 139010-0000 | STUD |
254. | [2] | 020106-1240 | BLEEDER SCREW M6P1.0L12 |
257. | [2] | 154156-0900 | TUBE |
300. | [1] | 159287-4800 | CAM PLATE |
301. | [1] | 016010-0840 | LOCKING WASHER |
303. | [1] | 016010-0540 | LOCKING WASHER |
311. | [1] | 159237-0200 | CAPSULE |
835S. | [1] | 154062-1900 | CAP D12L24 |
836S. | [1] | 154062-1700 | CAP D20L32 |
Include in #1:
101401-7322
as GOVERNOR
Cross reference number
Zexel num
Bosch num
Firm num
Name
105932-1852
8971429882 ISUZU
GOVERNOR
A K 14JK MECHANICAL GOVERNOR GOV RLD GOV
A K 14JK MECHANICAL GOVERNOR GOV RLD GOV
Information:
Bulk storage
Follow all local regulations covering bulk storage tanks. Follow proper tank construction guidelines. Tank volume typically should be 110% of planned capacity. Appropriately vent indoor tanks. Plan for control of overflow of the tank. Heat tanks that dispense DEF in cold climates.Bulk tank breathers should be fitted with filtration to keep airborne debris from entering the tank. Desiccant breathers should not be used because water will be absorbed, which potentially can alter DEF concentration.Handling
Follow all local regulations covering transport and handling. DEF transport temperature is recommended to be −5° C (23° F) to 25° C (77° F). All transfer equipment and intermediate containers should be used exclusively for DEF. Containers should not be reused for any other fluids. Ensure that transfer equipment is made from DEF-compatible materials. Recommended material for hoses and other non-metallic transfer equipment include:
Nitrile Rubber (NBR)
Fluoroelastomer (FKM)
Ethylene Propylene Diane Ionomer (EPDM)The condition of hoses and other nonmetallic items that are used with DEF should be monitored for signs of degradation. DEF leaks are easily recognizable by white urea crystals that accumulate at the site of the leak. Solid urea can be corrosive to galvanized or unalloyed steel, aluminum, copper, and brass. Leaks should be repaired immediately to avoid damage to surrounding hardware.Cleanliness
Contaminants can degrade the quality and life of DEF. Filtering DEF is recommended when dispensed into the DEF tank. Filters should be compatible with DEF and should be used exclusively with DEF. Check with the filter supplier to confirm compatibility with DEF before using. Mesh-type filters using compatible metals, such as stainless steel, are recommended. Paper (cellulose) media and some synthetic filter media are not recommended because of degradation during use.Care should be taken when dispensing DEF. Spills should be cleaned immediately. Machine or engine surfaces should be wiped clean and rinsed with water. Caution should be used when dispensing DEF near an engine that has recently been running.Note: Spilling DEF onto hot components may cause the release of ammonia vapors. Do not breathe ammonia vapors. Do not clean up any spills with bleach.Stability
DEF fluid is stable when stored and handled properly. The quality of DEF rapidly degrades when stored at high temperatures. The ideal storage temperature for DEF is between −9° C (15.8° F) and 25° C (77° F). DEF that is stored above 35° C (95° F) for longer than 1 month must be tested before use. Testing should evaluate Urea Percentage, Alkalinity as NH3 and Biuret content.The length of storage of DEF is listed in the following table:
Table 3
Storage Temperature Expected DEF Life
Below 25° C (77° F) 18 months
25° C (77° F) to 30° C (86° F) 12 months
30° C (86° F) to 35° C (95° F) 6 months
Above 35° C (95° F) test quality before use Refer to "ISO 22241" document series for more information about DEF quality control.Note: Dispose of all fluids according to applicable regulations and mandates.General Characteristics of DEF
For detailed information on the requirements and
Follow all local regulations covering bulk storage tanks. Follow proper tank construction guidelines. Tank volume typically should be 110% of planned capacity. Appropriately vent indoor tanks. Plan for control of overflow of the tank. Heat tanks that dispense DEF in cold climates.Bulk tank breathers should be fitted with filtration to keep airborne debris from entering the tank. Desiccant breathers should not be used because water will be absorbed, which potentially can alter DEF concentration.Handling
Follow all local regulations covering transport and handling. DEF transport temperature is recommended to be −5° C (23° F) to 25° C (77° F). All transfer equipment and intermediate containers should be used exclusively for DEF. Containers should not be reused for any other fluids. Ensure that transfer equipment is made from DEF-compatible materials. Recommended material for hoses and other non-metallic transfer equipment include:
Nitrile Rubber (NBR)
Fluoroelastomer (FKM)
Ethylene Propylene Diane Ionomer (EPDM)The condition of hoses and other nonmetallic items that are used with DEF should be monitored for signs of degradation. DEF leaks are easily recognizable by white urea crystals that accumulate at the site of the leak. Solid urea can be corrosive to galvanized or unalloyed steel, aluminum, copper, and brass. Leaks should be repaired immediately to avoid damage to surrounding hardware.Cleanliness
Contaminants can degrade the quality and life of DEF. Filtering DEF is recommended when dispensed into the DEF tank. Filters should be compatible with DEF and should be used exclusively with DEF. Check with the filter supplier to confirm compatibility with DEF before using. Mesh-type filters using compatible metals, such as stainless steel, are recommended. Paper (cellulose) media and some synthetic filter media are not recommended because of degradation during use.Care should be taken when dispensing DEF. Spills should be cleaned immediately. Machine or engine surfaces should be wiped clean and rinsed with water. Caution should be used when dispensing DEF near an engine that has recently been running.Note: Spilling DEF onto hot components may cause the release of ammonia vapors. Do not breathe ammonia vapors. Do not clean up any spills with bleach.Stability
DEF fluid is stable when stored and handled properly. The quality of DEF rapidly degrades when stored at high temperatures. The ideal storage temperature for DEF is between −9° C (15.8° F) and 25° C (77° F). DEF that is stored above 35° C (95° F) for longer than 1 month must be tested before use. Testing should evaluate Urea Percentage, Alkalinity as NH3 and Biuret content.The length of storage of DEF is listed in the following table:
Table 3
Storage Temperature Expected DEF Life
Below 25° C (77° F) 18 months
25° C (77° F) to 30° C (86° F) 12 months
30° C (86° F) to 35° C (95° F) 6 months
Above 35° C (95° F) test quality before use Refer to "ISO 22241" document series for more information about DEF quality control.Note: Dispose of all fluids according to applicable regulations and mandates.General Characteristics of DEF
For detailed information on the requirements and