105932-1571 ZEXEL 9 420 610 494 BOSCH GOVERNOR 9420610494 1059321571


 

Information governor

BOSCH 9 420 610 494 9420610494
ZEXEL 105932-1571 1059321571
105932-1571 GOVERNOR
Rating:
31
Buy GOVERNOR 105932-1571 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105932-1571 
9 420 610 494 
   
GOVERNOR
* K




Information:


Table 1
Part Number Container Size Volume of Finished Coolant Produced
351-9431 3.8 L (1 US gal) 50.5 L (13.3 US gal)
351-9432 20 L (5.3 US gal) 267 L (70.5 US gal)
351-9433 208 L (55 US gal) 2773 L (733 US gal)
366-2753 (1) 1000 L (264 US gal) 13333 L (3523 US gal)
(1) NACD and LACD onlyMixing Cat ELI
The recommended water for mixing with Cat ELI concentrate is distilled or deionized water. Water must meet requirements of ASTM 1193, "Type IV Reagent Water Specification". If distilled or deionized water is not available, water should meet the “Caterpillar Minimum Acceptable Water Requirements” provided in this Special Publication.To ensure a proper concentration, the preferred method is to mix Cat ELI concentrate with water. Then, add the mixed coolant to the engine cooling system. Add the proper amounts of water and Cat ELI into a clean container and mix thoroughly by manual stirring or mechanical agitation.If the preferred method cannot be performed, a Cat ELI mixture can be made by adding Cat ELI concentrate directly into engine cooling system. Add good quality water until the dilution level is approximately 7.5%. Adequate mixing is attained by operating the engine for at least 30 minutes.Appropriate mixing rates for available ELI container sizes are provided in Table 1.After the addition of water and proper mixing, the concentration of Cat ELI can be determined using the 360-0774 Digital Brix Refractometer.Changing to Cat ELI
For cooling systems previously running Cat ELC or an extended life coolant that meets Cat EC-1 requirements, drain the cooling system and flush with water. Then refill the cooling system with a mixture of 7.5% Cat ELI in water that meets the “Caterpillar Minimum Acceptable Water Requirements”.For cooling systems previously running a conventional heavy-duty coolant or a water/SCA mixture, follow the steps listed in this Special Publication, "Changing to Cat ELC". Then refill the cooling system with a mixture of 7.5% Cat ELI in water that meets the “Caterpillar Minimum Acceptable Water Requirements”.Cat ELI Maintenance
Maintenance of Cat ELI is similar to Cat ELC. A coolant sample should be submitted for S O S Level 2 Coolant Analysis after the first 500 hours of operation and then annually thereafter.Cat ELC Extender should be added at the midpoint of service life (typically 6,000 hours), or as recommended by S O S Coolant Analysis results.Analysis and interpretation of Cat ELI S O S results is similar to the analysis and interpretation of Cat ELC. There will be no glycol and glycol oxidation products, which do not apply to Cat ELI.The concentration of a sample of in-use Cat ELI taken from the cooling system can also be determined using the 360-0774 Digital Brix Refractometer.Note: Clean water is the only flushing agent that is required when Cat ELI is drained from a properly maintained cooling system.Mixing Cat ELI and Cat ELC
Since Cat ELI and Cat ELC are based on the same corrosion inhibitor technology, Cat ELI can be mixed with Cat

Have questions with 105932-1571?





Group cross 105932-1571 ZEXEL

Mitsubishi 

 
ME740387 
GOVERNOR
 
ME741400 
GOVERNOR
F 019 Z5E 853 
NP-EP/RLD275-1550A1FFL 
ME742342 
GOVERNOR
 
ME740406 
GOVERNOR
9 420 611 061 
ME740647 
GOVERNOR
9 420 611 557 
NP-EP/RLD275-1550A1FFL 
ME742175 
GOVERNOR

Isuzu 

9 420 611 357 
NP-EP/RLD300-1500A1FYL 
8971377820 
GOVERNOR
9 420 611 358 
NP-EP/RLD300-1500A1FYL 
8971377830 
GOVERNOR

Mitsubishi 

9 420 611 062 
ME740418 
GOVERNOR
9 420 611 063 
NP-EP/RLD275-1550A1FFL 
ME742200 
GOVERNOR
F 019 Z9E 027 
ME740422 
GOVERNOR
F 019 Z5E 854 
NP-EP/RLD275-1550A1FFL 
ME742201 
GOVERNOR
 
 

 
 
GOVERNOR
105932-1571  
9 420 610 494 
 
GOVERNOR
 
 

 
 

 
 

 
 

Back to top