105932-0181 ZEXEL GOVERNOR Cross 1059320181


 

Information governor

ZEXEL 105932-0181 1059320181
105932-0181 GOVERNOR
Rating:
17
Buy GOVERNOR 105932-0181 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105932-0181 
 
   
GOVERNOR




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00563543
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.Reference: Maintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.

Have questions with 105932-0181?





Group cross 105932-0181 ZEXEL

Mitsubishi 

 
ME731990 
GOVERNOR
F 019 Z5E 822 
NP-EP/RLD275-1550A1CFL 
ME738710 
GOVERNOR
 
ME731991 
GOVERNOR
 
ME738537 
GOVERNOR
 
ME738783 
GOVERNOR
9 420 610 485 
ME740026 
GOVERNOR
9 420 610 486 
NP-EP/RLD275-1550A1FFL 
ME742205 
GOVERNOR
9 420 613 865 
ME731992 
GOVERNOR
 
ME738538 
GOVERNOR
 
ME738591 
GOVERNOR
9 420 611 633 
ME740023 
GOVERNOR
 
ME740080 
GOVERNOR
9 420 611 057 
ME740653 
GOVERNOR
9 420 611 058 
NP-EP/RLD275-1550A1FFL 
ME741760 
GOVERNOR
 
ME738427 
GOVERNOR
9 420 613 649 
NP-EP/RLD275-1550A1FFL 
 
GOVERNOR

Isuzu 

9 420 613 942 
8971097360 
GOVERNOR
9 420 613 942 
8971096650 
GOVERNOR
F 019 Z1E 248 
8971096651 
GOVERNOR
F 01G 29N 064 
NP-EP/RLD275-1500A2FXL 
 
GOVERNOR

Isuzu 

9 420 613 943 
8971097340 
GOVERNOR
9 420 611 316 
NP-EP/RLD300-1950A2FFL 
8971097341 
GOVERNOR
9 420 612 702 
8971097350 
GOVERNOR
9 420 611 317 
NP-EP/RLD300-1950A2FBL 
8971097351 
GOVERNOR

Mitsubishi 

9 420 613 650 
NP-EP/RLD275-1550A1EFL 
ME738449 
GOVERNOR
9 420 613 097 
 
GOVERNOR
105932-0181  
 
 
GOVERNOR
 
 

 
 

Back to top