105931-8411 ZEXEL F 01G 29N 05K BOSCH GOVERNOR f01g29n05k 1059318411 me730366


 

Information governor

BOSCH F 01G 29N 05K f01g29n05k
ZEXEL 105931-8411 1059318411
MITSUBISHI ME730366 me730366
105931-8411 GOVERNOR
Rating:
21
Buy GOVERNOR 105931-8411 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105931-8411 
105931-8412 
F 01G 29N 05K 
ME730366  MITSUBISHI
GOVERNOR
* K 14JK GOV RLD GOV




Information:

The heat baths listed in Chart B meet the specified requirements and can be purchased from:Cole-Parmer Instruments Co.
7425 North Oakpark Ave.
Niles, IL, 60714 U.S.A.
Phone (800) 323-4340
Fax: (708) 647-9660
* Heat Bath Fluid The heat bath fluid must be able to obtain and maintain the required contactor actuation and deactuation temperatures. For the temperatures required for the calibration procedure, silicone fluid must be used. Silicone fluid has a temperature range between 10° C (50° F) and 230° C (446° F). Silicone fluid can be purchased from Cole-Parmer by ordering G-01294-40. The fluid comes in a 3.8 Liter (1 gal) container.
Use extreme caution around heat baths with high temperature fluids. High temperature fluids can cause severe burns.
Calibration Procedure
Use the following procedure to test and calibrate the temperature contactors.1. If connected, disconnect the contactor from the power supply. Mark the terminal location and disconnect the three wires from terminals 1, 2, and 4.
High voltage electrical shock is possible. The contactor must be disconnected from the power supply and the wires disconnected from terminals 1, 2, and 4. Failure to follow this recommendation can result in serious bodily injury.
2. Locate and record the part number of the temperature contactor in Chart A. This will determine the actuation and deactuation temperatures. If the temperature contactor is used in extreme ambient temperatures there will be a scale deviation from the required actuation and deactuation temperatures. Refer to the "Calculating Scale Correction for Severe Temperature Applications" section in this Special Instruction.
Temperature Contactor
(1) Housing cover. (2) Housing cover screws. (3) Temperature probe. (4) Capillary tube.3. Loosen housing cover screws (2) and remove housing cover (1).4. Fill the heat bath unit with silicone fluid and heat it to approximately 5° C (10° F) below the actuation temperature setting. Do not immerse the temperature probe at this time.
Nomenclature Of Internal Parts
(5). Lock screw. (6) Range spindle. (7) Range scale. (8) Differential spindle. (9) Differential scale.5. Loosen lock screw (5).6. Adjust range spindle (6) to a setting above the desired actuation setting determined in Step 2. Determine the setting by using range scale (7).7. Adjust the differential spindle (8) to the approximate mechanical differential temperature using differential scale (9). Mechanical differential temperature is the difference between the actuation and deactuation temperature settings.
Temperature Control Function For Actuation And Deactuation (specifically shown for 7C-3888 Contactor)
Adjusting Temperature and Differential Settings On The Temperature Contactor
This example shows the temperature set at 66° C with an 8° C differential setting. This results in a deactuation temperature of 58° C and actuation temperature of 66° C. (Refer to "Temperature Control Function For Actuation And Deactuation" illustration.)8. Fully immerse temperature probe (3) in the silicone fluid. Increase the heat bath temperature to the specified actuation temperature.9. When the actuation temperature has stabilized, very slowly turn range spindle (6) counterclockwise until the contact actuates. This will be accompanied by an audible "click".
When Contact Actuates, Terminals 1 And 4 Will Have Continuity10. Use a 6V-7070 Multimeter, or equivalent, to verify the actuation of the contactor. Check for continuity between

Have questions with 105931-8411?





Group cross 105931-8411 ZEXEL

9 420 613 050 
 
GOVERNOR
 
 
GOVERNOR

Isuzu 

F 019 Z9E 655 
8970473962 
GOVERNOR
9 420 613 051 
NP-EP/RLD300-1500A1FYL 
 
GOVERNOR

Mitsubishi 

F 019 Z9E 259 
ME727993 
GOVERNOR
105931-8411  

105931-8412 
F 01G 29N 05K 
ME730366 
GOVERNOR
9 420 613 626 
NP-EP/RLD275-1550A1EFL 
ME738890 
GOVERNOR
9 420 613 780 
NP-EP/RLD250-1550A4FFL 
 
GOVERNOR

Mitsubishi 

 
ME730416 
GOVERNOR
9 420 613 627 
NP-EP/RLD275-1550A1CFL 
 
GOVERNOR

Mitsubishi 

 
ME730209 
GOVERNOR
9 420 613 628 
NP-EP/RLD275-1550A1AFL 
 
GOVERNOR

Mitsubishi 

9 420 613 628 
NP-EP/RLD275-1550A1AFL 
ME756541 
GOVERNOR
F 019 Z1F 045 
 
GOVERNOR
F 019 Z1F 046 
 
GOVERNOR
F 019 Z9E 737 
 
GOVERNOR
F 019 Z3E 719 
NP-EP/RLD275-1470A1GYL 
 
GOVERNOR
F 019 Z1F 047 
 
GOVERNOR
F 019 Z1F 048 
 
GOVERNOR
F 019 Z9E 242 
 
GOVERNOR
F 019 Z3E 304 
NP-EP/RLD275-1470A1GXL 
 
GOVERNOR
F 019 Z1F 049 
 
GOVERNOR
F 019 Z1F 050 
 
GOVERNOR
F 019 Z1F 051 
 
GOVERNOR
F 019 Z9E 309 
 
GOVERNOR
F 019 Z9E 169 
NP-EP/RLD275-1470A1GXL 
 
GOVERNOR
Back to top