105923-3871 ZEXEL GOVERNOR Cross 1059233871


 

Information governor

ZEXEL 105923-3871 1059233871
105923-3871 GOVERNOR
Rating:
55
Buy GOVERNOR 105923-3871 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105923-3871 
 
   
GOVERNOR




Information:


Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine. Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 3 g00292636
Junction Box Wiring for ETR protection

Have questions with 105923-3871?





Group cross 105923-3871 ZEXEL

Mitsubishi 

9 420 611 830 
ME742750 
GOVERNOR
F 019 Z5E 645 
NP-EP/RLD225-1250T6JFR 
ME748566 
GOVERNOR
9 420 611 831 
NP-EP/RLD225-1250T6JFR 
ME742751 
GOVERNOR

Nissan-Diesel 

9 420 611 832 
NP-EP/RLD225-1250P6JXR 
1910195508 
GOVERNOR
F 019 Z5E 646 
NP-EP/RLD350-1600T1JXR 
19101Z6809 
GOVERNOR
9 420 611 833 
NP-EP/RLD350-1600T1JYR 
 
GOVERNOR

Nissan-Diesel 

F 019 Z5E 647 
NP-EP/RLD350-1600T1JXR 
19101Z6811 
GOVERNOR
 
 

Isuzu 

9 420 611 834 
1157709960 
GOVERNOR
105923-3871  
 
 
GOVERNOR

Isuzu 

F 019 Z2E 538 
NP-EP/RLD240-1200T6JXR 
1157709962 
GOVERNOR

Mitsubishi 

9 420 611 835 
NP-EP/RLD225-1250T6JFR 
ME742759 
GOVERNOR
9 420 614 424 
ME742760 
GOVERNOR
F 019 Z4E 115 
NP-EP/RLD225-1200P6JFR 
ME756233 
GOVERNOR
Back to top