105923-1292 ZEXEL F 019 Z5E 555 BOSCH GOVERNOR f019z5e555 1059231292 me748555


 

Information governor

BOSCH F 019 Z5E 555 f019z5e555
ZEXEL 105923-1292 1059231292
MITSUBISHI ME748555 me748555
105923-1292 GOVERNOR
Rating:
24
Buy GOVERNOR 105923-1292 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105923-1292 
F 019 Z5E 555 
NP-EP/RLD225-1200P6JFR 
ME748555  MITSUBISHI
GOVERNOR
K




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with Every 1000 Hour maintenance, perform all previous maintenance interval requirements.Engine Protection Devices
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A

Have questions with 105923-1292?





Group cross 105923-1292 ZEXEL

 
 
GOVERNOR

Mitsubishi 

 
ME740068 
GOVERNOR
9 420 612 188 
 
GOVERNOR
 
 
GOVERNOR

Mitsubishi 

 
ME738695 
GOVERNOR
 
ME738850 
GOVERNOR
9 420 613 845 
ME738897 
GOVERNOR
9 420 611 025 
ME740083 
GOVERNOR
F 019 Z2E 643 
NP-EP/RLD225-1200P6JXR 
ME742177 
GOVERNOR
 
 
GOVERNOR

Hino 

 
223008001A 
GOVERNOR
9 420 613 776 
223008002A 
GOVERNOR
9 420 610 649 
223008003A 
GOVERNOR
 
 
GOVERNOR

Mitsubishi 

 
ME738712 
GOVERNOR
F 019 Z5E 554 
NP-EP/RLD225-1200T6JFR 
ME740062 
GOVERNOR
 
 
GOVERNOR
9 420 610 650 
 
GOVERNOR

Hino 

9 420 610 651 
223009162A 
GOVERNOR
F 01G 29N 03L 
223009163A 
GOVERNOR
9 420 611 790 
 
GOVERNOR

Hino 

F 019 Z3E 305 
NP-EP/RLD250-1100T6JXR 
224001890A 
GOVERNOR
9 420 612 189 
223008150A 
GOVERNOR
9 420 610 941 
223008151A 
GOVERNOR
9 420 610 652 
 
GOVERNOR
F 01G 29N 03M 
NP-EP/RLD225-1150T6JFR 
 
GOVERNOR

Hino 

 
223008140A 
GOVERNOR
9 420 610 653 
223008141A 
GOVERNOR
 
 
GOVERNOR

Isuzu 

9 420 611 263 
NP-EP/RLD225-1250P5JFR 
1157708070 
GOVERNOR

Mitsubishi 

 
ME738864 
GOVERNOR
 
ME740065 
GOVERNOR
F 019 Z9E 031 
NP-EP/RLD225-1250T6JFR 
ME756262 
GOVERNOR
 
ME738878 
GOVERNOR
F 019 Z1E 479 
ME740054 
GOVERNOR
105923-1292  
F 019 Z5E 555 
NP-EP/RLD225-1200P6JFR 
ME748555 
GOVERNOR
Back to top