105923-1180 ZEXEL GOVERNOR Cross 1059231180 me738704


 

Information governor

ZEXEL 105923-1180 1059231180
MITSUBISHI ME738704 me738704
105923-1180 GOVERNOR
Rating:
61
Buy GOVERNOR 105923-1180 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105923-1180 
105923-1181 
 
ME738704  MITSUBISHI
GOVERNOR
* K




Information:

Storage Procedure
When a generator is in storage for any length of time, moisture condenses in the windings. Minimize the condensation by use of a dry storage space and space heaters. Refer to step 2 belowIf a brush-type generator (SRCR) is to be in storage for a year or more, lift the brushes off the slip ring to prevent damage to the slip ring by chemical action.After Storage
Test the main stator windings with a megohmmeter in the following situations: 1. Before initial startup of generator set.2. Every 3 months* if generator is operating in a humid environment.3. If generator has not been run under load for 3 months* or more.*This is a guideline only. It may be necessary to megger more frequently if environment is extremely humid, salty or if the last megger test was close to 1 megohm.The megohmmeter test is described in Service Manuals SENR2180 or SENR7968. A reading of 1 meghom or less indicates that the winding has absorbed too much moisture.To Remove Moisture
To remove moisture caused by high humidity, use one of the following methods to make the generator dry:1. Energize space heaters in generator if so equipped.2. Put the generator in an oven at a temperature of not more than 85°C (185°F) for four hours.
If an oven is used for drying, use a forced air type rather than a radiant type. Radiant ovens can cause localized overheating.
3. Space heaters of the same type used in marine applications, can be installed on generators. (See the Parts Book.) These heaters heat the windings to remove moisture and should be connected at all times in high humidity conditions whenever the generator is not running.4. Use a canvas enclosure around the generator and heating lamps to increase the temperature. Make an opening in the top for release of moisture.5. Send a low voltage current through the windings to increase the temperature of the windings. Do not exceed 85°C (185°F).If the megohmmeter test reads under 1 megohm after the drying or if it goes below 1 megohm shortly after drying, contact your Caterpillar dealer. The insulation has deteriorated and should be reconditioned.

Have questions with 105923-1180?





Group cross 105923-1180 ZEXEL

Mitsubishi 

F 019 Z5E 550 
NP-EP/RLD225-1250T6JFR 
ME738679 
GOVERNOR
 
ME738649 
GOVERNOR
F 019 Z3E 992 
NP-EP/RLD225-1250T6JFR 
ME738786 
GOVERNOR
 
ME738696 
GOVERNOR
 
ME738697 
GOVERNOR
F 019 Z5E 551 
NP-EP/RLD225-1200P6JXR 
ME738901 
GOVERNOR
F 01G 29N 03J 
ME738698 
GOVERNOR
F 01G 29N 03K 
ME738805 
GOVERNOR
9 420 611 022 
ME738898 
GOVERNOR
9 420 611 459 
ME740077 
GOVERNOR
F 019 Z5E 552 
NP-EP/RLD225-1200P6JXR 
ME742631 
GOVERNOR
 
ME738689 
GOVERNOR
 
ME738700 
GOVERNOR
 
ME738927 
GOVERNOR
 
ME738942 
GOVERNOR
9 420 611 625 
ME740085 
GOVERNOR
9 420 610 436 
ME740618 
GOVERNOR
9 420 611 496 
NP-EP/RLD225-1200P6JXR 
ME741716 
GOVERNOR
 
ME738701 
GOVERNOR
 
ME738780 
GOVERNOR
 
ME738943 
GOVERNOR
 
ME740084 
GOVERNOR
9 420 610 437 
ME740619 
GOVERNOR
9 420 611 626 
NP-EP/RLD225-1200P6JXR 
ME741717 
GOVERNOR
105923-1180  

105923-1181 
 
ME738704 
GOVERNOR
9 420 613 844 
ME738769 
GOVERNOR
9 420 611 023 
NP-EP/RLD225-1200P6JFR 
ME740052 
GOVERNOR
 
ME738699 
GOVERNOR
 
ME738858 
GOVERNOR
 
ME740103 
GOVERNOR
9 420 611 024 
ME740633 
GOVERNOR
F 019 Z5E 553 
NP-EP/RLD225-1250T6JFR 
ME742607 
GOVERNOR
Back to top