Information governor
BOSCH
9 420 612 128
9420612128
ZEXEL
105489-2130
1054892130
HINO
223005840A
223005840a

Rating:
Scheme ###:
1. | [1] | 154004-1300 | GOVERNOR HOUSING |
4. | [1] | 154367-6020 | CONTROL LEVER |
4. | [1] | 154367-6020 | CONTROL LEVER |
4/1. | [1] | 154304-6200 | CONTROL LEVER |
4/2. | [2] | 154352-2000 | BLEEDER SCREW |
4/2. | [2] | 154352-2000 | BLEEDER SCREW |
4/3. | [1] | 154367-6000 | CONTROL LEVER |
4/4. | [1] | 029311-0230 | SHIM D18&10.3T0.5 |
4/5. | [1] | 154321-1500 | BUSHING |
4/6. | [1] | 154327-4100 | COILED SPRING |
4/7. | [1] | 154322-0100 | CAP |
4/8. | [1] | 029311-0220 | SHIM D18&10.3T0.2 |
4/9. | [1] | 154324-2700 | LEVER SHAFT |
4/10. | [1] | 029631-0030 | O-RING &9.8W2.3 |
9. | [1] | 154353-5601 | PLATE |
10. | [4] | 020106-2040 | BLEEDER SCREW M6P1L20 |
11. | [4] | 020106-1840 | BLEEDER SCREW M6P1L18 |
12. | [1] | 154010-7300 | BLEEDER SCREW M8P1.25L60 |
13. | [1] | 013020-6040 | UNION NUT M6P1H5 |
14. | [1] | 154011-0100 | HEXAGON NUT |
14B. | [1] | 154011-2300 | UNION NUT |
35. | [1] | 154514-8220 | GOVERNOR COVER |
35/2. | [1] | 154321-2000 | BUSHING |
35/3. | [1] | 029621-0080 | PACKING RING |
38. | [1] | 154031-3401 | FLAT-HEAD SCREW |
39. | [1] | 029201-0160 | UNION NUT |
47. | [2] | 154036-1800 | CAPSULE |
47. | [2] | 154036-1800 | CAPSULE |
48. | [1] | 154010-5500 | BLEEDER SCREW M10P1.25L42 |
48B. | [1] | 154010-7100 | BLEEDER SCREW M10P1.25L47 |
49. | [1] | 154011-2200 | UNION NUT |
50. | [1] | 155615-2300 | FLAT-HEAD SCREW |
51. | [5] | 020106-4540 | BLEEDER SCREW M6P1.0L45 |
52. | [2] | 029010-6850 | BLEEDER SCREW |
53. | [1] | 154010-3100 | BLEEDER SCREW |
54. | [2] | 014110-6440 | LOCKING WASHER |
65. | [1] | 154610-2020 | RACK SENSOR ASSY |
65/1. | [1] | 479743-7020 | RACK SENSOR |
65/2. | [1] | 154614-2500 | JOINT CONNECTION |
65/3. | [1] | 154614-2900 | BLOCK |
65/4. | [1] | 010234-1040 | HEX-SOCKET-HEAD CAP SCREW |
65/5. | [1] | 014110-4440 | LOCKING WASHER |
65/6. | [1] | 026524-3040 | GASKET |
65/7. | [1] | 029310-6280 | SHIM D11.5&6.4T1.50 |
65/8. | [1] | 154614-1900 | UNION NUT |
65/9. | [1] | 154614-3300 | BEARING PIN |
67. | [1] | 154614-3600 | CLAMPING BAND |
68. | [1] | 020106-1240 | BLEEDER SCREW M6P1.0L12 |
70. | [1] | 154055-2320 | HEADLESS SCREW |
80. | [1] | 154063-4100 | COVER |
82. | [1] | 029020-6210 | BLEEDER SCREW |
83. | [1] | 029020-6210 | BLEEDER SCREW |
84. | [1] | 020006-1640 | BLEEDER SCREW M6P1L16 4T |
86. | [1] | 020006-1640 | BLEEDER SCREW M6P1L16 4T |
100. | [1] | 154100-9320 | FLYWEIGHT ASSEMBLY |
101. | [1] | 025803-1310 | WOODRUFF KEY |
102. | [1] | 029321-2020 | LOCKING WASHER |
103. | [1] | 139212-0000 | UNION NUT |
117. | [1] | 154123-2320 | SLIDING PIECE |
118/1. | [0] | 029311-0010 | SHIM D14&10.1T0.2 |
118/1. | [0] | 029311-0180 | SHIM D14&10.1T0.3 |
118/1. | [0] | 029311-0190 | SHIM D14&10.1T0.40 |
118/1. | [0] | 029311-0210 | SHIM D14&10.1T1 |
118/1. | [0] | 139410-0000 | SHIM D14.0&10.1T0.5 |
118/1. | [0] | 139410-0100 | SHIM D14.0&10.1T1.5 |
118/1. | [0] | 139410-3000 | SHIM D14&10.1T2.0 |
118/1. | [0] | 139410-3100 | SHIM D14&10.1T3.0 |
118/1. | [0] | 139410-3200 | SHIM D14&10.1T4.0 |
130. | [1] | 154150-9000 | GOVERNOR SPRING |
132. | [1] | 154154-0701 | COILED SPRING |
140. | [1] | 154183-4120 | HEADLESS SCREW |
141. | [1] | 139218-0100 | UNION NUT |
142. | [1] | 154242-3120 | HEADLESS SCREW |
143. | [1] | 154242-3200 | UNION NUT |
144. | [1] | 026516-2040 | GASKET D19.9&16.2T1 |
145. | [1] | 154159-1800 | CAP NUT |
146. | [1] | 029331-6130 | GASKET |
150. | [1] | 154200-5401 | SWIVELLING LEVER |
151. | [1] | 154200-5501 | BUSHING |
151. | [1] | 154200-5501 | BUSHING |
152. | [2] | 139700-0000 | O-RING |
152. | [2] | 139700-0000 | O-RING |
153. | [2] | 154354-3900 | LOCKING WASHER |
153. | [2] | 154354-3900 | LOCKING WASHER |
154. | [1] | 139610-0101 | PACKING RING |
155. | [1] | 139411-0100 | SHIM D22.0&12.0T0.40 |
156. | [0] | 139411-0200 | SHIM D18.0&12.0T0.10 |
156B. | [0] | 139411-0300 | SHIM D18.0&12.0T0.20 |
156C. | [0] | 139411-0400 | SHIM D18.0&12.0T0.30 |
157. | [1] | 154204-3500 | BUSHING |
159. | [1] | 025803-1310 | WOODRUFF KEY |
162. | [1] | 029331-6050 | GASKET |
163. | [1] | 154401-3201 | BLEEDER SCREW |
164. | [1] | 154243-0720 | CONTROL LEVER |
165. | [1] | 154327-6000 | COILED SPRING |
166. | [1] | 029310-8320 | SHIM D16.5&8T0.2 |
167. | [1] | 154356-3600 | LOCKING WASHER |
170. | [1] | 154217-4720 | FORK LEVER |
173. | [1] | 016010-0540 | LOCKING WASHER |
174. | [1] | 154230-8120 | STRAP |
179. | [1] | 154238-0201 | BEARING PIN |
180. | [1] | 016010-0540 | LOCKING WASHER |
181. | [1] | 154236-7521 | TENSIONING LEVER |
182. | [1] | 154237-1200 | BEARING PIN |
183. | [2] | 154237-1300 | BUSHING |
190. | [1] | 154360-2800 | CONTROL LEVER |
191. | [1] | 154340-4320 | CONTROL LEVER |
192. | [1] | 020006-1670 | BLEEDER SCREW M6P1L16 7T |
193. | [1] | 154368-7820 | CONTROL LEVER |
194. | [2] | 020006-1240 | BLEEDER SCREW M6P1L12 4T |
195. | [2] | 154317-5200 | COILED SPRING |
196. | [2] | 154156-1300 | TUBE |
203/1. | [0] | 029311-0640 | SHIM D26.0&10.2T0.95 |
203/1. | [0] | 029311-0650 | SHIM D26.0&10.2T0.20 |
203/1. | [0] | 029311-0660 | SHIM D26.0&10.2T0.25 |
203/1. | [0] | 029311-0670 | SHIM D26.0&10.2T0.30 |
203/1. | [0] | 029311-0680 | SHIM D26.0&10.2T0.35 |
203/1. | [0] | 029311-0690 | SHIM D26.0&10.2T0.40 |
203/1. | [0] | 029311-0700 | SHIM D26.0&10.2T0.50 |
203/1. | [0] | 139410-1400 | SHIM D26&10.2T0.7 |
203/1. | [0] | 139410-1500 | SHIM D26&10.2T0.9 |
203/1. | [0] | 139410-1600 | SHIM D26&10.2T0.8 |
203/1. | [0] | 139410-2700 | SHIM D26&10.2T0.6 |
205. | [1] | 154324-4100 | LEVER SHAFT |
207. | [1] | 154326-0300 | CONTROL LEVER |
211. | [1] | 016010-0840 | LOCKING WASHER |
220. | [1] | 154050-8220 | HEADLESS SCREW |
221. | [1] | 029201-2140 | UNION NUT |
222. | [2] | 026512-1540 | GASKET D15.4&12.2T1.50 |
223. | [1] | 154159-1200 | CAP NUT |
235. | [1] | 155412-5200 | IMPELLER WHEEL |
236. | [1] | 154371-5600 | GASKET |
237. | [1] | 154390-0200 | GASKET |
238. | [1] | 139700-0100 | O-RING |
331. | [1] | 154179-4920 | HEADLESS SCREW |
332. | [1] | 139218-0200 | UNION NUT |
335. | [1] | 154352-2600 | CAPSULE |
336. | [1] | 029331-6030 | GASKET |
350. | [1] | 154356-0221 | BRACKET |
351. | [3] | 029010-5340 | BLEEDER SCREW |
835S. | [2] | 154062-1700 | CAP D20L32 |
835S. | [2] | 154062-1700 | CAP D20L32 |
900S. | [1] | 025803-1310 | WOODRUFF KEY |
901S. | [1] | 025803-1610 | WOODRUFF KEY |
Include in #1:
106871-8420
as GOVERNOR
Cross reference number
Zexel num
Bosch num
Firm num
Name
105489-2130
223005840A HINO
GOVERNOR
K 14JN MECHANICAL GOVERNOR GOV RFD GOV
K 14JN MECHANICAL GOVERNOR GOV RFD GOV
105489-2130
223006320A HINO
GOVERNOR
A K 14JN MECHANICAL GOVERNOR GOV RFD GOV
A K 14JN MECHANICAL GOVERNOR GOV RFD GOV
Information:
You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with this maintenance interval, perform previous maintenance interval requirements. Perform the maintenance at the interval listed in the Maintenance Schedule for your engine.Engine Protection Controls
Inspect For Proper Operation
The engine protective alarm and shutoff controls must be tested, inspected and checked by an authorized Caterpillar dealer at least every year or 1000 hours for proper operation. The manual shutoff functions should be tested to ensure proper operation and protection to the engine. Refer to Engine Control, Monitoring and Protection in the Operation Section in this Manual. Have the checks made by a qualified mechanic. Consult your authorized Caterpillar engine dealer, or refer to the Service Manual for your engine. Check Alarm and Shutdown Settings
Check for loose, broken, or damaged wiring or components. Check the condition of all sensors and wiring. Repair or replace any broken or malfunctioning sensors before they become a problem. The inspection only takes a few minutes and could avert a potential problem that could cause your engine to fail. Check GSC Display Window Readings
Refer to the operating parameters in the Engine Control, Monitoring and Protection topic.While operating, observe all GSC display window readings hourly, especially the engine oil pressure, fuel pressure and coolant temperature.Operational Checks
Start the engine. Use the starting procedure found in the Engine Starting topic in this publication.The operational checks are intended to check the engine starting and stopping, lubrication and fuel systems as well as overall operation. The checks should take no longer than five minutes to complete. Longer periods of operation are not required. A more thorough Performance Analysis should be performed with the engine operating under load.Automatic Switches
Check that all switches are in proper position for automatic start. The shutoff controls must be checked so that they function properly when they are required. To prevent damage to the engine while performing the test, only authorized personnel or your Caterpillar dealer should perform the checks.SR4 Generator
Make sure residual voltage in the rotor, stator and the generator is discharged.If this generator is to be connected to a utility electrical distribution system, it must be isolated from the distribution system by means of:a. Opening the main switch in the case of the generator temporarily connected to the system or,b. A double throw (transfer) switch in the case of a permanent connection to the system.Failure to do so could result in personal injury or death due to electrical shock. This warning does not apply when a generator and utility distribution system are designed and approved by the utility to run in parallel.
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Check Winding Insulation Resistance
When the engine-generator is operating, voltages up to 600V are present in these areas near
Inspect For Proper Operation
The engine protective alarm and shutoff controls must be tested, inspected and checked by an authorized Caterpillar dealer at least every year or 1000 hours for proper operation. The manual shutoff functions should be tested to ensure proper operation and protection to the engine. Refer to Engine Control, Monitoring and Protection in the Operation Section in this Manual. Have the checks made by a qualified mechanic. Consult your authorized Caterpillar engine dealer, or refer to the Service Manual for your engine. Check Alarm and Shutdown Settings
Check for loose, broken, or damaged wiring or components. Check the condition of all sensors and wiring. Repair or replace any broken or malfunctioning sensors before they become a problem. The inspection only takes a few minutes and could avert a potential problem that could cause your engine to fail. Check GSC Display Window Readings
Refer to the operating parameters in the Engine Control, Monitoring and Protection topic.While operating, observe all GSC display window readings hourly, especially the engine oil pressure, fuel pressure and coolant temperature.Operational Checks
Start the engine. Use the starting procedure found in the Engine Starting topic in this publication.The operational checks are intended to check the engine starting and stopping, lubrication and fuel systems as well as overall operation. The checks should take no longer than five minutes to complete. Longer periods of operation are not required. A more thorough Performance Analysis should be performed with the engine operating under load.Automatic Switches
Check that all switches are in proper position for automatic start. The shutoff controls must be checked so that they function properly when they are required. To prevent damage to the engine while performing the test, only authorized personnel or your Caterpillar dealer should perform the checks.SR4 Generator
Make sure residual voltage in the rotor, stator and the generator is discharged.If this generator is to be connected to a utility electrical distribution system, it must be isolated from the distribution system by means of:a. Opening the main switch in the case of the generator temporarily connected to the system or,b. A double throw (transfer) switch in the case of a permanent connection to the system.Failure to do so could result in personal injury or death due to electrical shock. This warning does not apply when a generator and utility distribution system are designed and approved by the utility to run in parallel.
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Check Winding Insulation Resistance
When the engine-generator is operating, voltages up to 600V are present in these areas near