105489-0911 ZEXEL GOVERNOR Cross 1054890911 223004161a


 

Information governor

ZEXEL 105489-0911 1054890911
HINO 223004161A 223004161a
105489-0911 GOVERNOR
Rating:
83
Buy GOVERNOR 105489-0911 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105489-0911 
105489-0901 
 
223004161A  HINO
GOVERNOR
*




Information:

Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 105489-0911?





Group cross 105489-0911 ZEXEL

Hino 

 
223004150A 
GOVERNOR
9 420 612 124 
NP-EP/RFD200/1300PF66DHR 
223004151A 
GOVERNOR
 
223004160A 
GOVERNOR
105489-0911  

105489-0901 
 
223004161A 
GOVERNOR

Mitsubishi 

 
ME722751 
GOVERNOR
 
ME723158 
GOVERNOR
F 019 Z4E 998 
NP-EP/RFD200/1300PF10DWR 
ME723410 
GOVERNOR

Isuzu 

9 420 612 925 
1157703720 
GOVERNOR

Nissan-Diesel 

F 019 Z2F 261 
1910196770 
GOVERNOR

Hino 

F 019 Z4E 999 
NP-EP/RFD200/1300PF66DHR 
223004360A 
GOVERNOR
 
223004370A 
GOVERNOR
9 420 610 308 
NP-EP/RFD200/1650PF9BHR 
223004350A 
GOVERNOR

Mitsubishi 

 
ME722956 
GOVERNOR
 
ME723159 
GOVERNOR
F 019 Z1E 441 
NP-EP/RFD200/1300PF10DWR 
ME723411 
GOVERNOR

Nissan-Diesel 

F 019 Z5E 000 
NP-EP/RFD200/1300PF28DHR 
1910196771 
GOVERNOR
Back to top