Information governor
BOSCH
9 420 611 643
9420611643
ZEXEL
105447-1432
1054471432
MITSUBISHI-HEAV
34A6503270
34a6503270

Rating:
Scheme ###:
1. | [1] | 154002-4220 | GOVERNOR HOUSING |
5. | [1] | 154007-1600 | CAPSULE |
10. | [8] | 139006-4100 | BLEEDER SCREW |
12. | [1] | 154034-0800 | BLEEDER SCREW |
13. | [2] | 154011-0100 | HEXAGON NUT |
13. | [2] | 154011-0100 | HEXAGON NUT |
15. | [2] | 139608-0200 | PACKING RING |
15. | [2] | 139608-0200 | PACKING RING |
16. | [1] | 155004-4900 | LEVER SHAFT |
18. | [1] | 155003-3100 | CONTROL LEVER |
19. | [1] | 155006-0700 | BLEEDER SCREW |
20. | [1] | 139308-0900 | PLAIN WASHER D16&8T1 |
20B. | [1] | 139308-1000 | PLAIN WASHER D16&8T1.5 |
21. | [0] | 029310-8050 | SHIM D13.5&8T0.5 |
22. | [0] | 029310-8050 | SHIM D13.5&8T0.5 |
23. | [1] | 025520-1210 | SPLIT PIN |
24. | [1] | 154206-2000 | BUSHING |
25. | [1] | 154327-4200 | COILED SPRING |
26. | [1] | 154381-9300 | CONTROL LEVER |
27. | [1] | 014110-8440 | LOCKING WASHER |
28. | [1] | 013030-8140 | UNION NUT M8P1.25H5 |
35. | [1] | 154520-6520 | GOVERNOR COVER |
38. | [1] | 154031-3800 | FLAT-HEAD SCREW |
39. | [1] | 139206-0600 | UNION NUT |
47. | [1] | 154036-0300 | CAPSULE |
51. | [4] | 020106-5040 | BLEEDER SCREW |
52. | [3] | 020106-2840 | BLEEDER SCREW |
53. | [1] | 154010-0200 | FLAT-HEAD SCREW |
65. | [1] | 153021-4020 | STOPPING DEVICE |
66. | [1] | 026524-3040 | GASKET |
80. | [1] | 154063-7700 | COVER |
82. | [1] | 029020-6240 | BLEEDER SCREW |
83. | [1] | 029020-6250 | BLEEDER SCREW |
84. | [1] | 029020-6240 | BLEEDER SCREW |
85. | [2] | 014110-6440 | LOCKING WASHER |
85. | [2] | 014110-6440 | LOCKING WASHER |
86. | [1] | 029020-6250 | BLEEDER SCREW |
100. | [1] | 154101-0220 | FLYWEIGHT |
101. | [1] | 025803-1310 | WOODRUFF KEY |
102. | [1] | 029321-2020 | LOCKING WASHER |
103. | [1] | 029231-2030 | UNION NUT |
104. | [1] | 154120-0100 | PLAIN WASHER |
106. | [1] | 029602-0020 | LOCKING WASHER |
107. | [1] | 154121-0500 | TOOTHED GEAR |
108. | [1] | 016610-2640 | BEARING PLATE |
109. | [1] | 028102-0010 | BEARING PLATE |
111. | [1] | 154134-0000 | SPACER BUSHING |
112. | [1] | 154122-0300 | COVER |
113. | [1] | 029614-7020 | LOCKING WASHER |
114. | [1] | 025803-1610 | WOODRUFF KEY |
115. | [1] | 029321-2020 | LOCKING WASHER |
116. | [1] | 029231-2030 | UNION NUT |
117. | [1] | 154123-1920 | SLIDING PIECE |
118/1. | [0] | 029311-0010 | SHIM D14&10.1T0.2 |
118/1. | [0] | 029311-0180 | SHIM D14&10.1T0.3 |
118/1. | [0] | 029311-0190 | SHIM D14&10.1T0.40 |
118/1. | [0] | 029311-0210 | SHIM D14&10.1T1 |
118/1. | [0] | 139410-0000 | SHIM D14.0&10.1T0.5 |
118/1. | [0] | 139410-0100 | SHIM D14.0&10.1T1.5 |
118/1. | [0] | 139410-3000 | SHIM D14&10.1T2.0 |
118/1. | [0] | 139410-3100 | SHIM D14&10.1T3.0 |
118/1. | [0] | 139410-3200 | SHIM D14&10.1T4.0 |
119. | [1] | 154130-1820 | TOOTHED GEAR |
119/2. | [1] | 154132-0320 | HOLDER |
119/3. | [4] | 153251-0100 | DAMPER |
119/4. | [1] | 139329-0000 | PLAIN WASHER |
119/5. | [1] | 016020-2810 | LOCKING WASHER |
122. | [3] | 020106-2840 | BLEEDER SCREW |
132. | [1] | 154154-0900 | COILED SPRING |
133. | [2] | 154156-0100 | TUBE |
135. | [1] | 154157-6020 | HEADLESS SCREW |
136. | [1] | 029201-2130 | UNION NUT M12P1.0H6 |
137. | [2] | 026512-1540 | GASKET D15.4&12.2T1.50 |
138. | [1] | 154159-1200 | CAP NUT |
140. | [1] | 154186-1420 | HEADLESS SCREW |
141. | [1] | 029201-6210 | UNION NUT |
150. | [1] | 154200-4520 | SWIVELLING LEVER |
151. | [1] | 154204-2100 | BUSHING |
152. | [2] | 139716-0100 | O-RING |
152. | [2] | 139716-0100 | O-RING |
153. | [2] | 016010-1640 | LOCKING WASHER |
153. | [2] | 016010-1640 | LOCKING WASHER |
154. | [1] | 139611-0200 | PACKING RING |
155. | [1] | 029311-1010 | SHIM |
158. | [1] | 154204-2200 | BUSHING |
159. | [1] | 025803-1310 | WOODRUFF KEY |
170. | [1] | 154217-2820 | FORK LEVER |
172. | [3] | 029310-5170 | SHIM D8&5.3T0.5 |
172. | [3] | 029310-5170 | SHIM D8&5.3T0.5 |
173. | [2] | 025520-1210 | SPLIT PIN |
173. | [2] | 025520-1210 | SPLIT PIN |
174. | [1] | 154234-9220 | STRAP |
175. | [1] | 016010-0540 | LOCKING WASHER |
176. | [1] | 154232-2700 | CONNECTOR |
177. | [2] | 029050-5040 | FLAT-HEAD SCREW M5P0.8L9 |
181. | [1] | 154239-2720 | TENSIONING LEVER |
182. | [1] | 154237-1500 | BEARING PIN |
190. | [1] | 154396-0020 | CONTROL LEVER |
236. | [1] | 154371-5600 | GASKET |
237. | [1] | 154371-3500 | GASKET |
238. | [1] | 154390-3500 | GASKET |
255. | [1] | 154400-7420 | DIAPHRAGM |
256. | [1] | 154400-4800 | STOP PIN |
257. | [2] | 029330-8050 | GASKET |
257. | [2] | 029330-8050 | GASKET |
259. | [1] | 154372-7200 | HEXAGON NUT |
260. | [1] | 154401-4420 | CONTROL LEVER |
261. | [1] | 154401-1020 | STRAP |
262. | [1] | 026510-1440 | GASKET D13.9&10.2T1 |
263. | [1] | 154401-4500 | BLEEDER SCREW |
264. | [1] | 016010-0540 | LOCKING WASHER |
265. | [1] | 154222-6200 | BEARING PIN |
266. | [1] | 029300-4010 | PLAIN WASHER |
267. | [1] | 154416-3500 | COILED SPRING |
268. | [1] | 154404-5000 | COVER |
269. | [2] | 020106-2240 | BLEEDER SCREW |
270. | [1] | 154034-1900 | FLAT-HEAD SCREW |
271. | [1] | 013030-6040 | UNION NUT M6P1H3.6 |
273. | [1] | 029731-0120 | EYE BOLT |
274. | [2] | 029341-0110 | GASKET |
275. | [0] | 029312-0180 | SHIM D25.5&20T0.5 |
275B. | [0] | 029312-0210 | SHIM D25.5&20T0.2 |
276. | [1] | 154035-1600 | CAP NUT |
277. | [1] | 029320-6010 | LOCKING WASHER |
278. | [2] | 154413-2600 | GASKET |
279. | [2] | 026506-1040 | GASKET D9.9&6.2T1 |
283. | [1] | 016010-0440 | LOCKING WASHER |
285. | [1] | 029010-6310 | BLEEDER SCREW |
300. | [1] | 154010-0300 | FLAT-HEAD SCREW |
301. | [1] | 154011-0100 | HEXAGON NUT |
331. | [1] | 154186-1220 | HEADLESS SCREW |
332. | [1] | 029201-6010 | UNION NUT |
335. | [2] | 026506-1040 | GASKET D9.9&6.2T1 |
336. | [1] | 154035-1600 | CAP NUT |
349. | [1] | 026510-1340 | GASKET D13.4&10.2T1 |
350. | [1] | 154036-1600 | ADAPTOR |
351. | [1] | 139806-0000 | EYE BOLT |
352. | [2] | 029340-6120 | GASKET |
353. | [2] | 029310-9080 | SHIM D16&9T1.7 |
900S. | [1] | 025803-1310 | WOODRUFF KEY |
901S. | [1] | 025803-1610 | WOODRUFF KEY |
Include in #1:
106681-4174
as GOVERNOR
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
You should follow the instructions in Operations and Maintenance Manual, "Initialization for Direct Connection" before you connect by a modem. The user can verify proper operation of the CCM at the location. The user can also become familiar with the CCM. Make sure that the following equipment is available:
A personal computer with a terminal emulator software program. Examples of terminal emulators include Procomm, PC-VT, or Terminal under the Accessories window in Microsoft Windows. Refer to "Caterpillar CCM PC For Windows: Getting Started Manual" for specifications on the PC. The user is responsible for understanding the operation of the PC.
The proper RS-232C cables are required for the particular installation. An RS-232C cable must be temporarily connected from the PC to the Answering Modem. Refer to Operation and Maintenance Manual, "RS-232C Cable Requirements".
The two modems must support the Hayes AT command set. This is necessary for both the Answering Modem and the Originating Modem.
The CCM PC For Windows software is required. This software is available from Caterpillar.Note: Some personal computers will have an internal modem. The internal modem may be used as the Originating Modem. The internal modem must be compatible with the Answering Modem. Consult the instructions for the two modems.ProcedurePerform the following procedure in order to initialize communication with the CCM and the Answering Modem. The Originating Modem is set up later by the PC software.Note: In the following steps, the PC and the modems should be turned OFF before you change the cables on the serial ports. When power is reapplied, the modem must be powered up first.
The CCM should be installed with all of the wiring. Refer to the Operations and Maintenance Manual, "General Wiring Diagram" and "RS-232C Cable Requirements".
Determine the parameters for communication for the installation. The RS-232C default rate of communication (bits per second or bps) is 9600. The remaining default settings from the factory are no parity, 8 data bits, and 1 stop bit. These parameters will work well in most installations. Use the Operation and Maintenance Manual, "Communication Parameters - Identify" to determine the parameters of communication that are stored in the CCM.Note: The RS-232C serial port communication baud rate is often referred to as the DTE speed. The phone port communication rate is often referred to as the DCE speed.
Connect the RS-232C port of the Answering Modem directly to the RS-232C port of the PC. This connection is temporary. This connection is required to set up the Answering Modem.
Use the terminal emulator on the PC to set the parameters for communication for the RS-232C port. Use the same values that were chosen in step 2.
Several commands must be sent to the Answering Modem that set the parameters for communication to the proper values. The examples in Table 1 are Hayes AT commands. Actual command sets vary widely between modem manufacturers. Consult the manual for the modem. Save these parameters to the modem memory.
Table 1
Typical Answering Modem Setup Commands    
Item     Explanation     Command Example     Command
A personal computer with a terminal emulator software program. Examples of terminal emulators include Procomm, PC-VT, or Terminal under the Accessories window in Microsoft Windows. Refer to "Caterpillar CCM PC For Windows: Getting Started Manual" for specifications on the PC. The user is responsible for understanding the operation of the PC.
The proper RS-232C cables are required for the particular installation. An RS-232C cable must be temporarily connected from the PC to the Answering Modem. Refer to Operation and Maintenance Manual, "RS-232C Cable Requirements".
The two modems must support the Hayes AT command set. This is necessary for both the Answering Modem and the Originating Modem.
The CCM PC For Windows software is required. This software is available from Caterpillar.Note: Some personal computers will have an internal modem. The internal modem may be used as the Originating Modem. The internal modem must be compatible with the Answering Modem. Consult the instructions for the two modems.ProcedurePerform the following procedure in order to initialize communication with the CCM and the Answering Modem. The Originating Modem is set up later by the PC software.Note: In the following steps, the PC and the modems should be turned OFF before you change the cables on the serial ports. When power is reapplied, the modem must be powered up first.
The CCM should be installed with all of the wiring. Refer to the Operations and Maintenance Manual, "General Wiring Diagram" and "RS-232C Cable Requirements".
Determine the parameters for communication for the installation. The RS-232C default rate of communication (bits per second or bps) is 9600. The remaining default settings from the factory are no parity, 8 data bits, and 1 stop bit. These parameters will work well in most installations. Use the Operation and Maintenance Manual, "Communication Parameters - Identify" to determine the parameters of communication that are stored in the CCM.Note: The RS-232C serial port communication baud rate is often referred to as the DTE speed. The phone port communication rate is often referred to as the DCE speed.
Connect the RS-232C port of the Answering Modem directly to the RS-232C port of the PC. This connection is temporary. This connection is required to set up the Answering Modem.
Use the terminal emulator on the PC to set the parameters for communication for the RS-232C port. Use the same values that were chosen in step 2.
Several commands must be sent to the Answering Modem that set the parameters for communication to the proper values. The examples in Table 1 are Hayes AT commands. Actual command sets vary widely between modem manufacturers. Consult the manual for the modem. Save these parameters to the modem memory.
Table 1
Typical Answering Modem Setup Commands    
Item     Explanation     Command Example     Command