Information governor
BOSCH
F 019 Z3E 902
f019z3e902
ZEXEL
105447-1083
1054471083

Rating:
Scheme ###:
1. | [1] | 154002-3520 | GOVERNOR HOUSING |
5. | [1] | 154007-1600 | CAPSULE |
10. | [8] | 139006-4100 | BLEEDER SCREW |
12. | [1] | 154010-3900 | BLEEDER SCREW |
13. | [2] | 154011-0100 | HEXAGON NUT |
13. | [2] | 154011-0100 | HEXAGON NUT |
15. | [2] | 139608-0200 | PACKING RING |
15. | [2] | 139608-0200 | PACKING RING |
16. | [1] | 155004-4900 | LEVER SHAFT |
18. | [1] | 155003-3100 | CONTROL LEVER |
19. | [1] | 155006-0700 | BLEEDER SCREW |
20. | [1] | 139308-1100 | PLAIN WASHER |
21. | [0] | 029310-8050 | SHIM D13.5&8T0.5 |
22. | [0] | 029310-8050 | SHIM D13.5&8T0.5 |
23. | [1] | 155402-3800 | SAFETY PIN |
24. | [1] | 154206-2000 | BUSHING |
26. | [1] | 154382-8600 | CONTROL LEVER |
27. | [1] | 014110-8440 | LOCKING WASHER |
28. | [1] | 013020-8040 | UNION NUT M8P1.25H7 |
35. | [1] | 154520-6920 | GOVERNOR COVER |
38. | [1] | 154031-3000 | FLAT-HEAD SCREW |
39. | [1] | 139206-0600 | UNION NUT |
47. | [2] | 154036-0300 | CAPSULE |
47. | [2] | 154036-0300 | CAPSULE |
51. | [4] | 020106-5040 | BLEEDER SCREW |
52. | [3] | 020106-2840 | BLEEDER SCREW |
53. | [1] | 154010-0300 | FLAT-HEAD SCREW |
80. | [1] | 154063-9900 | COVER |
82. | [1] | 029020-6210 | BLEEDER SCREW |
83. | [1] | 029020-6260 | BLEEDER SCREW |
84. | [1] | 029020-6260 | BLEEDER SCREW |
86. | [1] | 029020-6260 | BLEEDER SCREW |
100. | [1] | 154100-9720 | FLYWEIGHT ASSEMBLY |
101. | [1] | 025803-1610 | WOODRUFF KEY |
102. | [1] | 029321-2020 | LOCKING WASHER |
103. | [1] | 029231-2030 | UNION NUT |
104. | [1] | 154120-0100 | PLAIN WASHER |
106. | [1] | 029602-0020 | LOCKING WASHER |
107. | [1] | 154121-0500 | TOOTHED GEAR |
108. | [1] | 016610-2640 | BEARING PLATE |
109. | [1] | 028102-0010 | BEARING PLATE |
111. | [1] | 154134-0000 | SPACER BUSHING |
112. | [1] | 154122-0300 | COVER |
113. | [1] | 029614-7020 | LOCKING WASHER |
114. | [1] | 025803-1310 | WOODRUFF KEY |
115. | [1] | 029321-2020 | LOCKING WASHER |
116. | [1] | 029231-2030 | UNION NUT |
117. | [1] | 154123-1020 | SLIDING PIECE |
118/1. | [0] | 029311-0010 | SHIM D14&10.1T0.2 |
118/1. | [0] | 029311-0180 | SHIM D14&10.1T0.3 |
118/1. | [0] | 029311-0190 | SHIM D14&10.1T0.40 |
118/1. | [0] | 029311-0210 | SHIM D14&10.1T1 |
118/1. | [0] | 139410-0000 | SHIM D14.0&10.1T0.5 |
118/1. | [0] | 139410-0100 | SHIM D14.0&10.1T1.5 |
118/1. | [0] | 139410-3000 | SHIM D14&10.1T2.0 |
118/1. | [0] | 139410-3100 | SHIM D14&10.1T3.0 |
118/1. | [0] | 139410-3200 | SHIM D14&10.1T4.0 |
119. | [1] | 154130-1820 | TOOTHED GEAR |
119/2. | [1] | 154132-0320 | HOLDER |
119/3. | [4] | 153251-0100 | DAMPER |
119/4. | [1] | 139329-0000 | PLAIN WASHER |
119/5. | [1] | 016020-2810 | LOCKING WASHER |
122. | [3] | 020106-2840 | BLEEDER SCREW |
132. | [1] | 154154-3900 | COILED SPRING |
133. | [2] | 154156-0100 | TUBE |
135. | [1] | 154158-3720 | HEADLESS SCREW |
136. | [1] | 154371-3400 | UNION NUT |
137. | [2] | 026520-2440 | GASKET D23.9&20.2T1 |
138. | [1] | 154159-2000 | CAP NUT |
140. | [1] | 154186-0220 | HEADLESS SCREW |
141. | [1] | 029201-6010 | UNION NUT |
150. | [1] | 154200-6420 | SWIVELLING LEVER |
151. | [1] | 154204-4100 | BUSHING |
152. | [1] | 139718-0200 | O-RING |
152B. | [1] | 139716-0100 | O-RING |
153. | [2] | 016010-1640 | LOCKING WASHER |
153. | [2] | 016010-1640 | LOCKING WASHER |
154. | [1] | 139611-0200 | PACKING RING |
155. | [1] | 029311-1010 | SHIM |
158. | [1] | 154204-2200 | BUSHING |
159. | [1] | 025803-1310 | WOODRUFF KEY |
170. | [1] | 154217-2820 | FORK LEVER |
172. | [3] | 029310-5170 | SHIM D8&5.3T0.5 |
172. | [3] | 029310-5170 | SHIM D8&5.3T0.5 |
173. | [2] | 025520-1210 | SPLIT PIN |
173. | [2] | 025520-1210 | SPLIT PIN |
174. | [1] | 154234-9220 | STRAP |
175. | [1] | 016010-0540 | LOCKING WASHER |
176. | [1] | 154232-2700 | CONNECTOR |
177. | [2] | 029050-5040 | FLAT-HEAD SCREW M5P0.8L9 |
181. | [1] | 154236-9620 | TENSIONING LEVER |
182. | [1] | 154237-0200 | BEARING PIN |
190. | [1] | 154349-9920 | CONTROL LEVER |
195. | [1] | 154332-7600 | COILED SPRING |
236. | [1] | 154371-5600 | GASKET |
237. | [1] | 154371-3500 | GASKET |
238. | [1] | 154371-3600 | GASKET |
255. | [1] | 154400-7820 | DIAPHRAGM |
256. | [1] | 154400-4800 | STOP PIN |
257. | [2] | 029330-8050 | GASKET |
257. | [2] | 029330-8050 | GASKET |
259. | [1] | 154372-7200 | HEXAGON NUT |
260. | [1] | 154401-4420 | CONTROL LEVER |
261. | [1] | 154401-1020 | STRAP |
262. | [1] | 026510-1440 | GASKET D13.9&10.2T1 |
263. | [1] | 154401-4500 | BLEEDER SCREW |
264. | [1] | 016010-0540 | LOCKING WASHER |
265. | [1] | 154222-6200 | BEARING PIN |
266. | [1] | 029300-4010 | PLAIN WASHER |
267. | [1] | 154403-4800 | COILED SPRING |
268. | [1] | 154404-5000 | COVER |
269. | [2] | 020106-2240 | BLEEDER SCREW |
270. | [1] | 154034-1900 | FLAT-HEAD SCREW |
271. | [1] | 013030-6040 | UNION NUT M6P1H3.6 |
273. | [1] | 029731-0120 | EYE BOLT |
274. | [2] | 029341-0110 | GASKET |
275. | [0] | 029312-0180 | SHIM D25.5&20T0.5 |
275B. | [0] | 029312-0210 | SHIM D25.5&20T0.2 |
276. | [1] | 154035-1600 | CAP NUT |
277. | [1] | 029320-6010 | LOCKING WASHER |
278. | [2] | 154413-2600 | GASKET |
279. | [2] | 026506-1040 | GASKET D9.9&6.2T1 |
283. | [1] | 016010-0440 | LOCKING WASHER |
285. | [1] | 029010-6310 | BLEEDER SCREW |
300. | [1] | 154010-0300 | FLAT-HEAD SCREW |
301. | [1] | 154011-0100 | HEXAGON NUT |
335. | [2] | 026506-1040 | GASKET D9.9&6.2T1 |
336. | [1] | 154035-1600 | CAP NUT |
338. | [1] | 131002-3800 | ADAPTOR |
339. | [2] | 029341-2140 | GASKET |
340. | [1] | 154373-1800 | INLET UNION |
341. | [1] | 154373-1700 | EYE BOLT |
353. | [3] | 029310-9080 | SHIM D16&9T1.7 |
411. | [1] | 154370-0220 | BRACKET |
900S. | [1] | 025803-1310 | WOODRUFF KEY |
901S. | [1] | 025803-1610 | WOODRUFF KEY |
Cross reference number
Zexel num
Bosch num
Firm num
Name
105447-1083
GOVERNOR
K 14JC MECHANICAL GOVERNOR GOV RSUV(D) GOV
K 14JC MECHANICAL GOVERNOR GOV RSUV(D) GOV
Information:
Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00563543
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.Reference: Maintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00563543
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.Reference: Maintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".