105447-0831 ZEXEL 9 420 613 220 BOSCH GOVERNOR 9420613220 1054470831


 

Information governor

BOSCH 9 420 613 220 9420613220
ZEXEL 105447-0831 1054470831
105447-0831 GOVERNOR
Rating:
67
Buy GOVERNOR 105447-0831 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 154002-3320 GOVERNOR HOUSING
5. [1] 154007-1600 CAPSULE
10. [8] 139006-4100 BLEEDER SCREW
12. [1] 154010-3900 BLEEDER SCREW
13. [1] 154011-0100 HEXAGON NUT
35. [1] 154520-5720 GOVERNOR COVER
38. [1] 154031-3000 FLAT-HEAD SCREW
39. [1] 139206-0600 UNION NUT
47. [2] 154036-0300 CAPSULE
47. [2] 154036-0300 CAPSULE
51. [4] 020106-5040 BLEEDER SCREW
52. [3] 020106-2840 BLEEDER SCREW
53. [1] 154010-5220 HEADLESS SCREW
54. [1] 154011-1900 UNION NUT
65. [1] 153021-3120 STOPPING DEVICE
66. [1] 026524-3040 GASKET
80. [1] 154063-8200 COVER
82. [1] 029020-6210 BLEEDER SCREW
83. [1] 029020-6260 BLEEDER SCREW
84. [1] 029020-6260 BLEEDER SCREW
86. [1] 029020-6260 BLEEDER SCREW
100. [1] 154100-9920 FLYWEIGHT ASSEMBLY
101. [1] 025803-1310 WOODRUFF KEY
102. [1] 029321-2020 LOCKING WASHER
103. [1] 029231-2030 UNION NUT
104. [1] 154120-0100 PLAIN WASHER
106. [1] 029602-0020 LOCKING WASHER
107. [1] 154121-0500 TOOTHED GEAR
108. [1] 016610-2640 BEARING PLATE
109. [1] 028102-0010 BEARING PLATE
111. [1] 154134-0000 SPACER BUSHING
112. [1] 154122-0300 COVER
113. [1] 029614-7020 LOCKING WASHER
114. [1] 025803-1610 WOODRUFF KEY
115. [1] 029321-2020 LOCKING WASHER
116. [1] 029231-2030 UNION NUT
117. [1] 154123-1020 SLIDING PIECE
118/1. [0] 029311-0010 SHIM D14&10.1T0.2
118/1. [0] 029311-0180 SHIM D14&10.1T0.3
118/1. [0] 029311-0190 SHIM D14&10.1T0.40
118/1. [0] 029311-0210 SHIM D14&10.1T1
118/1. [0] 139410-0000 SHIM D14.0&10.1T0.5
118/1. [0] 139410-0100 SHIM D14.0&10.1T1.5
118/1. [0] 139410-3000 SHIM D14&10.1T2.0
118/1. [0] 139410-3100 SHIM D14&10.1T3.0
118/1. [0] 139410-3200 SHIM D14&10.1T4.0
119. [1] 154130-1820 TOOTHED GEAR
119/3. [4] 153251-0100 DAMPER
119/4. [1] 139329-0000 PLAIN WASHER
119/5. [1] 016020-2810 LOCKING WASHER
122. [3] 020106-2840 BLEEDER SCREW
132. [1] 154154-2900 COILED SPRING
133. [2] 154156-0100 TUBE
135. [1] 154158-3320 HEADLESS SCREW
136. [1] 029201-2290 UNION NUT
137. [2] 026512-1540 GASKET D15.4&12.2T1.50
138. [1] 154159-1200 CAP NUT
140. [1] 154185-5320 HEADLESS SCREW
141. [1] 029201-6010 UNION NUT
150. [1] 154200-4520 SWIVELLING LEVER
151. [1] 154204-2100 BUSHING
152. [2] 139716-0100 O-RING
152. [2] 139716-0100 O-RING
153. [2] 016010-1640 LOCKING WASHER
153. [2] 016010-1640 LOCKING WASHER
154. [1] 139611-0200 PACKING RING
155. [1] 029311-1010 SHIM
158. [1] 154204-2200 BUSHING
159. [1] 025803-1310 WOODRUFF KEY
170. [1] 154211-5420 FORK LEVER
174. [1] 154230-0220 STRAP
175. [1] 016010-0540 LOCKING WASHER
176. [1] 154232-0400 CONNECTOR
177. [2] 029050-5040 FLAT-HEAD SCREW M5P0.8L9
181. [1] 154236-5721 TENSIONING LEVER
182. [1] 154237-0200 BEARING PIN
190. [1] 154395-7020 CONTROL LEVER
195. [1] 154317-2500 COILED SPRING
236. [1] 154371-5600 GASKET
237. [1] 154371-3500 GASKET
238. [1] 154390-3500 GASKET
335. [2] 026506-1040 GASKET D9.9&6.2T1
336. [1] 154035-1600 CAP NUT
338. [1] 131002-3800 ADAPTOR
339. [2] 029341-2140 GASKET
340. [1] 029711-2350 INLET UNION
341. [1] 029731-2240 EYE BOLT
411. [1] 154370-0220 BRACKET
900S. [1] 025803-1310 WOODRUFF KEY
901S. [1] 025803-1610 WOODRUFF KEY

Include in #1:

106682-4541 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105447-0831 
9 420 613 220 
NP-EP/RSUV210-1250PP40/2 
   
GOVERNOR
K




Information:

Problem 5
The engine shutdown occurs after the engine runs for more than 3 minutes.
Check the overspeed setting on the electronic speed switch (ESS).
Observe the indicator lamp on the ESS.
Reset the air shutoff lever, if equipped.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The indicator lamp on the ESS is turned on.Overspeed is indicated as the cause of the engine shutdown. Press the "RESET" button of the ESS. Find the cause of the overspeed. Refer to Testing and Adjusting, "Overspeed Verification Test" and Testing and Adjusting, "Overspeed Calibration". If the overspeed is adjusted properly and the problem persists, check the shielded cable. Only the shield should be connected to terminal 2 on the ESS. STOP.
The indicator lamp is turned off.Go to Step 2.
Check the protection switches.
Remove the jumper that is between terminals (TS-9) and (TS-10) of the junction box.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The problem is in the oil pressure switches or the water temperature contactor switch. Go to Step 8 of "Problem 1".
The engine starts but engine shutdown occurs immediately.Go to Step 1 of "Problem 3".
The engine starts and the engine runs but engine shutdown occurs after the engine runs for more than 3 minutes.Go to Step 3.
The engine cranks but the engine does not start.Go to Step 1 of "Problem 1".
Check the start/stop switch.
Disconnect the wire in the junction box that connects terminal (SR1-85) of the slave relay (SR1) to terminal (TD-7) of the time delay relay (TD).
Disconnect the wire from terminal (TD-7) and insulate the exposed wire.
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch has a short circuit or a wiring problem is causing a voltage at terminal (TD-7). Reconnect the wire to the terminal.
Check the start/stop switch.
Disconnect the wire that runs from the STOP position of terminal (SSS-6) to terminal (TD-6). Terminal (SSS-6) is on the start/stop switch.
Disconnect the wire at terminal (TD-7).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the switch. STOP.
Engine shutdown still occurs.Reconnect the wire to terminal (TD-7). Go to Step 5
Check the slave relay (SR1).
Disconnect the wire that connects terminal (TS-10) of the junction box to terminal (TD-6) of the time delay relay.
Disconnect the wire at terminal (TD-6).
Crank the engine. Stop the engine with the emergency stop switch, if trouble occurs.Result
The engine starts and the engine runs.The start/stop switch is faulty. Replace the start/stop switch. STOP.
Engine shutdown still occurs.The contacts of SR1 periodically close. The problem may also be with the governor or the fuel supply to the engine. Refer to the Engine Service Manual. If a 2301A Electric Governor is used, the SR1 contacts may be opening. Refer to 2301A Electric Governor Service Manual, SENR3585. Test SR1. Refer to Testing and Adjusting, "Slave Relay Test".Problem 6
Engine shutdown does not occur

Have questions with 105447-0831?





Group cross 105447-0831 ZEXEL

9 420 612 807 
NP-EP/RSUV210-1250PP20/301 
 
GOVERNOR
9 420 614 172 
NP-EP/RSUV110-720PQ33/301 
 
GOVERNOR
9 420 612 808 
NP-EP/RSUV175-1050PQ35/301 
 
GOVERNOR
9 420 614 157 
 
GOVERNOR
105447-0831  
9 420 613 220 
NP-EP/RSUV210-1250PP40/2 
 
GOVERNOR
F 019 Z1E 546 
NP-EP/RSUV175-1050PQ35/301 
 
GOVERNOR
 
 
GOVERNOR
9 420 612 459 
NP-EP/RSUV210-1250PP40/2 
 
GOVERNOR
 
 

9 420 614 038 
 
GOVERNOR
9 420 612 460 
NP-EP/RSUV175-1050PQ35/302 
 
GOVERNOR

Mitsubishi-Heav 

9 420 612 788 
NP-EP/RSUV175-1000PP39/302 
35A6503360 
GOVERNOR
9 420 612 809 
NP-EP/RSUV175-1050PQ35/301 
 
GOVERNOR
Back to top