105419-4871 ZEXEL GOVERNOR Cross 1054194871


 

Information governor

ZEXEL 105419-4871 1054194871
105419-4871 GOVERNOR
Rating:
67
Buy GOVERNOR 105419-4871 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105419-4871 
 
   
GOVERNOR




Information:

Test Points (Voltages And Waveforms)
dc Voltages Conditions: 1. dc input voltage applied to POWER connector as shown.2. CALIBRATION CHECK/OPERATE switch in the OPERATE position.3. Neither transducer connected to indicator.4. TPI is reference for all voltages.Equipment Required: 6V3030 Digital Multimeterdc Input Voltages Waveforms Conditions: 1. dc power input voltage of 25 1 Volts.2. CALIBRATION CHECK/OPERATE switch in the CHECK position (can be held in CHECK position with tape).3. Neither transducer connected to indicator.4. TPI is reference for all waveforms.Equipment Required: dc oscilloscope (dual channel preferred). Waveform Time Relationships
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 2.66 ms WHICH IS BASED ON A 12.000 kHz OSCILLATOR FREQ. (1C202). SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Waveform Time Relationships (enlarged scale)
VOLTAGES MAY VARY 10%, PULSE DURATIONS BY 20% EXCEPT 83.3 ?s AND 2.66 ms WHICH ARE EXACT BASED ON A 12.000 kHZ OSCILLATOR. (1C202) SIGNAL SOURCE IS INTERNAL CALIBRATOR. ALL TEST POINTS REFERENCED TO TP1.Disassembly Procedure
1 Remove six screws (1) from front panel (2), and remove panel (2) from case (3). Remove four screws (4) from the PC board, and also remove the locknuts from the two front panel switches (5) and (6). Carefully lift front panel (2) from PC (printed circuit) board (7).Calibration Procedure
To make sure the 6V3100 Timing Indicator Group (1) has good accuracy, check its calibration at a minimum of every six months. Also, the timing indicator will need calibration if: A. It does not show 2000 30 R/MIN at (A) and 32.0 .2 DEG at (B), when the CALIBRATION CHECK-OPERATE Switch (C) is in the CALIBRATION CHECK position. With no input signal at (D) or (E), the reading at R/MIN location (A) must show three zeros (000). If four zeros (0000) show, it is an indication of a possible need for calibration of the unit. This error only is not reason enough to do a complete calibration procedure. It is also not necessary to do a complete calibration procedure if the reading at the DEG location (B) has a decimal point as shown, (00.0) in addition to the three zeros.B. Reading is different than (000) at either location (A) or (B).All calibrations can be done with the use of a small screwdriver, a frequency counter and

Have questions with 105419-4871?





Group cross 105419-4871 ZEXEL

F 019 Z2E 723 
NP-EP/RSV200-1350AQ55C311K 
 
GOVERNOR
F 019 Z2E 824 
NP-EP/RSV200-1300AQ44C311K 
 
GOVERNOR
F 019 Z2F 537 
NP-EP/RSV200-1350AQ55C311K 
 
GOVERNOR

Isuzu 

F 019 Z2E 973 
NP-EP/RSV200-1450AQ52A311 
8973137030 
GOVERNOR
F 019 Z2E 974 
NP-EP/RSV200-1450AQ52A311 
8973149300 
GOVERNOR
F 019 Z3E 077 
NP-EP/RSV200-1350AQ49A301 
8973225560 
GOVERNOR
F 019 Z3E 078 
NP-EP/RSV200-1300AQ39A301 
8973225570 
GOVERNOR
F 019 Z3E 147 
 
GOVERNOR
105419-4871  
 
 
GOVERNOR
F 019 Z3E 499 
NP-EP/RSV200-1350AQ49A311 
 
GOVERNOR
F 019 Z3E 146 
NP-EP/RSV200-1350AQ49C311K 
 
GOVERNOR
F 019 Z9E 440 
 
GOVERNOR
F 019 Z3E 311 
 
GOVERNOR
F 019 Z3E 656 
NP-EP/RSV200-1500AQ59C311K 
 
GOVERNOR
Back to top