105419-2920 ZEXEL GOVERNOR Cross 1054192920


 

Information governor

ZEXEL 105419-2920 1054192920
105419-2920 GOVERNOR
Rating:
22
Buy GOVERNOR 105419-2920 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105419-2920 
 
   
GOVERNOR




Information:

Prior to stopping an engine that is being operated at low loads, run the engine at low idle for 30 seconds before stopping. But, if the engine is being operated at highway speeds and/or high loads, then it should be run at low idle for three minutes to reduce and stabilize internal engine temperature before stopping.To stop the engine, use the method listed that applies to the shutoff system on your truck.1. Turn the key switch to the OFF position, or2. ... pull OUT the manual shutoff control (if equipped), or3. ... push IN and hold the stop button until the engine stops, then release the button.Make sure the shutoff procedure is understood. Refer to the truck manufacturer's instructions for your type of engine shutoff system used. Fill the fuel tank at the end of each day of operation to drive out moist air and to prevent condensation. Do not fill the tank to the top. Fuel expands as it gets warm and may overflow.Manual Fuel Shutoff Lever
A manual shutdown lever is provided to override the governor control of the engine. The manual shutoff solenoid override lever is located on the side of the fuel pump. This shutdown will only move the fuel control linkage to the FUEL-OFF position. It does not shut off the air inlet. Shutoff Solenoid Override
The manual shutoff solenoid override lever is located on the side of the electronic governor. The engine can be shut OFF by rotating and holding the manual shutoff lever in the counterclockwise (CCW) direction. Rotating and holding the manual shutoff lever in the clockwise (CW) direction overrides the shutoff solenoid. The lever is spring loaded and will return to the neutral position when released.If the solenoid has been disabled, the engine cannot be shut OFF from inside the cab. The engine can be shut OFF by using the manual shutoff lever as an emergency shutoff lever.
DO NOT operate the engine without the rack actuator solenoid (BTM) in place and with the fuel shutoff solenoid disabled. Excessive engine speed (overspeed) may result.

Have questions with 105419-2920?





Group cross 105419-2920 ZEXEL

9 420 611 722 
 
GOVERNOR
9 420 611 723 
NP-EP/RSV200-1300AQ39A311 
 
GOVERNOR
105419-2920  
 
 
GOVERNOR
9 420 614 817 
 
GOVERNOR
F 019 Z2E 605 
 
GOVERNOR
F 019 Z1E 960 
NP-EP/RSV200-1350AQ49A311 
 
GOVERNOR

Isuzu 

9 420 614 858 
NP-EP/RSV200-1450AQ43A311 
8971884300 
GOVERNOR
9 420 611 724 
NP-EP/RSV200-1350AQ49A301 
8971896800 
GOVERNOR
 
 

9 420 611 725 
 
GOVERNOR
F 019 Z2E 698 
 
GOVERNOR
F 019 Z3E 496 
NP-EP/RSV200-1300AQ39A311 
 
GOVERNOR

Isuzu 

F 019 Z2F 547 
1157900860 
GOVERNOR
 
8971918060 
GOVERNOR
9 420 614 607 
NP-EP/RSV200-1350AQ49A311 
8971918061 
GOVERNOR
9 420 614 608 
NP-EP/RSV200-1350AQ49A301 
 
GOVERNOR
Back to top