105408-0470 ZEXEL GOVERNOR Cross 1054080470 me726301


 

Information governor

ZEXEL 105408-0470 1054080470
MITSUBISHI ME726301 me726301
105408-0470 GOVERNOR
Rating:
22
Buy GOVERNOR 105408-0470 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
105408-0470 
105408-0471 
 
ME726301  MITSUBISHI
GOVERNOR
*




Information:

1. Remove the pickup from the injection line. Check to be sure the pickup and injection line are clean and dry. The inner bore of the pickup that contacts the injection line must be clean and dry. If necessary, clean the inner bore with a soft dry cloth. If the pickup is damp, dry it in an oven at approximately 50°C (122°F) before reinstalling on the fuel injection line.2. Check the fuel injection line on which the pickup was installed. Make sure all paint has been removed from around the line and that clean bare metal is exposed. Use fine emery paper to clean the line if necessary.3. Reinstall the pickup on the fuel injection line. Make sure the thumbscrew is tight and the pickup is not touching anything except the line. Observe the NO INPUT SIGNAL light and the digital readout on the multitach. If the light stays on bright all the time and the digital display reads 0 when the engine is running, the pickup is not operating. Remove the pickup and amplifier, and test the pickup and amplifier as shown on pages 6 and 7, or use a different pickup and amplifier.4. If the pickup is operating but the NO INPUT SIGNAL light and digital readout are erratic, the pickup output signal is either too low or it is noisy. Run the engine at low and high speeds. If the output signal is too low, the pickup will operate better at high engine speeds. If the signal is noisy, the pickup will usually perform better at low engine speeds. To correct either of these problems, loosen the thumbscrew and rotate the pickup to a new position on the line. Tighten the thumbscrew. Check to see if this solves the problem. To correct noisy operation, it may also be necessary to remove the pickup and reverse it 180° so the signal line points in the opposite direction.5. If pickup operation is still erratic after performing the previous steps, move the pickup to a new location on the same line or to a different line. Make sure each new location is properly prepared before installing pickup. To correct noisy operation (erratic signal and high speed readings), try a pickup location as close as possible to a point where the injection line is fastened to the engine.(D) Use Of The Pickup During Wet Conditions
If the pickup becomes wet, it may operate intermittently or not at all. Although the pickup is water resistant, it is not waterproof. Water spray from rain or other sources may cause the pickup to stop producing an output signal. If this happens, the pickup should be removed from the engine and allowed to dry out thoroughly. If necessary, the pickup can be dried in an oven at approximately 50°C (122°F). After drying, the pickup should operate correctly. If it is not possible to keep the pickup dry, use the following procedure. If the pickup must be used during wet conditions, it may be possible

Have questions with 105408-0470?





Group cross 105408-0470 ZEXEL

Mitsubishi 

F 019 Z4E 415 
NP-EP/RSV200-1300PQ44/312 
ME723853 
GOVERNOR
9 420 612 323 
NP-EP/RSV200-1300PQ39/311 
ME723860 
GOVERNOR

Nissan-Diesel 

F 019 Z2F 080 
1910196160 
GOVERNOR
 
 
GOVERNOR

Mitsubishi 

 
ME723874 
GOVERNOR
F 019 Z1E 387 
NP-EP/RSV200-1300PQ39/311 
ME726398 
GOVERNOR
F 019 Z4E 416 
NP-EP/RSV200-1200PQ36/311 
ME726253 
GOVERNOR
F 019 Z4E 417 
NP-EP/RSV200-1300PQ44/312 
ME726281 
GOVERNOR
 
ME726299 
GOVERNOR
9 420 614 912 
NP-EP/RSV200-1300PQ39/311 
ME726351 
GOVERNOR
105408-0470  

105408-0471 
 
ME726301 
GOVERNOR
 
ME726352 
GOVERNOR
F 019 Z1E 388 
NP-EP/RSV200-1300PQ39/311 
ME726397 
GOVERNOR
 
ME726316 
GOVERNOR
9 420 614 699 
NP-EP/RSV200-1300PQ39/311 
ME726350 
GOVERNOR
F 019 Z4E 418 
NP-EP/RSV200-1200PQ36/311 
ME726333 
GOVERNOR