105407-4820 ZEXEL 9 420 613 475 BOSCH GOVERNOR 9420613475 1054074820 223203600a


 

Information governor

BOSCH 9 420 613 475 9420613475
ZEXEL 105407-4820 1054074820
HINO 223203600A 223203600a
105407-4820 GOVERNOR
Rating:
18
Buy GOVERNOR 105407-4820 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 154000-4700 GOVERNOR HOUSING
3. [1] 029632-5070 O-RING
4. [1] 154007-2900 CAPSULE
9. [1] 154350-6000 PLATE
10. [8] 020106-2040 BLEEDER SCREW M6P1L20
10. [8] 020106-2040 BLEEDER SCREW M6P1L20
12. [1] 154010-1100 FLAT-HEAD SCREW
13. [2] 154011-0100 HEXAGON NUT
13. [2] 154011-0100 HEXAGON NUT
35. [1] 154501-0320 GOVERNOR COVER
35/2. [1] 154321-0400 BUSHING
38. [1] 154031-4300 FLAT-HEAD SCREW
39. [1] 139208-0400 UNION NUT
47. [1] 154036-0300 CAPSULE
51. [2] 020106-5040 BLEEDER SCREW
53. [1] 154010-0100 FLAT-HEAD SCREW
56. [4] 020106-3840 BLEEDER SCREW
65. [1] 155404-1700 CAP
66. [1] 026524-3040 GASKET
80. [1] 154063-7300 COVER
82. [2] 029020-6210 BLEEDER SCREW
83. [2] 020006-1640 BLEEDER SCREW M6P1L16 4T
100. [1] 154101-1320 FLYWEIGHT
101. [1] 025803-1310 WOODRUFF KEY
102. [1] 029321-2020 LOCKING WASHER
103. [1] 029231-2030 UNION NUT
117. [1] 154123-2320 SLIDING PIECE
118/1. [0] 029311-0010 SHIM D14&10.1T0.2
118/1. [0] 029311-0180 SHIM D14&10.1T0.3
118/1. [0] 029311-0190 SHIM D14&10.1T0.40
118/1. [0] 029311-0210 SHIM D14&10.1T1
118/1. [0] 139410-0000 SHIM D14.0&10.1T0.5
118/1. [0] 139410-0100 SHIM D14.0&10.1T1.5
118/1. [0] 139410-3000 SHIM D14&10.1T2.0
118/1. [0] 139410-3100 SHIM D14&10.1T3.0
118/1. [0] 139410-3200 SHIM D14&10.1T4.0
130. [1] 154150-0400 GOVERNOR SPRING
132. [1] 154154-0500 COILED SPRING
135. [1] 154158-1320 HEADLESS SCREW
136. [1] 154011-2700 UNION NUT
137. [2] 026512-1540 GASKET D15.4&12.2T1.50
138. [1] 154159-1200 CAP NUT
140. [1] 154177-3220 HEADLESS SCREW
141. [1] 029201-6010 UNION NUT
150. [1] 154200-7020 SWIVELLING LEVER
151. [1] 154204-3000 BUSHING
152. [2] 029631-8020 O-RING
152. [2] 029631-8020 O-RING
153. [2] 016010-1640 LOCKING WASHER
153. [2] 016010-1640 LOCKING WASHER
154. [1] 139611-0000 PACKING RING
155. [1] 139411-0000 SHIM
156. [0] 029311-1070 SHIM D16&11T0.5
157. [1] 154204-3100 BUSHING
159. [1] 025803-1310 WOODRUFF KEY
160. [1] 154206-2800 BUSHING
161. [0] 154206-0200 PLAIN WASHER D19.5&11.2T1.0
170. [1] 154210-2720 FORK LEVER
174. [1] 154230-2920 STRAP
175. [1] 016010-0540 LOCKING WASHER
181. [1] 154236-4100 TENSIONING LEVER
182. [1] 154237-1100 BEARING PIN
190. [1] 154341-8120 CONTROL LEVER
191. [1] 154380-6120 CONTROL LEVER
192. [1] 020006-3540 BLEEDER SCREW
201. [1] 029631-0030 O-RING &9.8W2.3
203. [1] 154322-0100 CAP
207. [1] 154326-5020 CONTROL LEVER
208. [1] 154327-7600 COILED SPRING
211/1. [0] 029311-0520 SHIM D20.8&10.3T0.2
211/1. [0] 029311-0530 SHIM D20.8&10.3T0.25
211/1. [0] 029311-0540 SHIM D20.8&10.3T0.3
211/1. [0] 029311-0550 SHIM D20.8&10.3T0.35
211/1. [0] 029311-0560 SHIM D20.8&10.3T0.4
211/1. [0] 029311-0570 SHIM D20.8&10.3T0.5
236. [1] 154371-5600 GASKET
237. [1] 154390-0300 GASKET
238. [1] 029635-2020 O-RING
335. [2] 026508-1140 GASKET D11.4&8.2T1
336. [1] 154035-2000 CAP NUT
900S. [1] 025803-1310 WOODRUFF KEY
901S. [1] 025803-1610 WOODRUFF KEY

Include in #1:

106671-8510 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105407-4820 
9 420 613 475 
NP-EP/RSV200-1300PQ39C312 
223203600A  HINO
GOVERNOR
K




Information:

Daily or every 8 Hours (whichever occurs first)
Check coolant level.Check oil level in sump (make sure machine is standing level).Check oil pressure (where a gauge is fitted).In extreme dust conditions, clean oil bath air cleaner or empty dust bowl on dry type air cleaner.Every 200 Hours or 4 Months (whichever occurs first)
Clean oil bath air cleaner or empty dust bowl on dry type cleaner.Check drive belt tension.Clean fuel water trap (where fitted).Every 400 Hours or 12 Months (whichever occurs first)
Drain and renew engine lubricating oil.Renew lubricating oil filter canister.Renew final fuel filter element.Clean lift pump sediment chamber.Every 800 Hours
Renew dry type air filter element.Every 2,400 Hours
Arrange for examination and service of proprietary equipment, i.e. starter motor, alternator, etc.Service atomisers.Check and adjust valve clearance.Post-Delivery Checkover
After a customer has taken delivery of his Perkins Diesel engine, a general checkover of the engine must be carried out by an experienced fitter after the first 500/1,000 miles (800/1600 km) or 25/50 hours in service with the engine warm.The checkover should comprise the following points:-1. Drain lubricating oil sump and refill to full mark on dipstick with new oil. See list of Approved Lubricating Oils in Appendix. When the sump is drained and it is possible to gain access to the sump strainer, it is recommended that this be cleaned.2. Renew the lubricating oil filter element.3. Remove the rocker assembly; tighten the cylinder head nuts/setscrews in the correct sequence (see Fig. E.12) and to the correct torque (see Page B.2). (Not necessary for 4.2482 The correct procedure for retightening of cylinder head nuts/setscrews is given on Page E.7. Reset valve tip clearances.4. Check coolant level and check for leaks.5. Check external nuts, setscrews, hose clips, mountings etc. for tightness.6. Check fan belt tension.7. Check electrical equipment and connections.8. Check for lubricating oil leaks.9. Check slow running speed (see Page N.9).10. Check general performance of engine. Routine maintenance should follow as detailed under Preventive Maintenance.Protection of an engine not in service
The recommendations given below are to ensure that damage is prevented when an engine is removed from service for an extended period. Use these procedures immediately the engine is removed from service. The instructions for the use of POWERPART products are given on the outside of each container.1. Thoroughly clean the outside of the engine.2. Where a preservative fuel is to be used, drain the fuel system and fill with the preservative fuel. POWERPART Lay-Up 1 can be added to the normal fuel to change it to a preservative fuel. If preservative fuel is not used, the system can be kept charged with normal fuel but this will have to be drained and discarded at the end of the storage period together with the fuel filter.3. Run the engine until it is warm. Correct any fuel, lubricating oil or air leakage. Stop the engine and drain the lubricating oil sump.4. Renew the lubricating oil filter canister.5. Fill the sump to the full mark on the dipstick with clean new lubricating oil or with

Have questions with 105407-4820?





Group cross 105407-4820 ZEXEL

Mitsubishi 

9 420 612 317 
NP-EP/RSV200-1300PQ39/311 
ME730320 
GOVERNOR
9 420 612 318 
NP-EP/RSV200-1300PQ39/311 
ME730321 
GOVERNOR

Hino 

105407-4820  
9 420 613 475 
NP-EP/RSV200-1300PQ39C312 
223203600A 
GOVERNOR

Mitsubishi 

F 019 Z4E 348 
NP-EP/RSV200-1300PQ44/312 
ME730322 
GOVERNOR
9 420 610 717 
NP-EP/RSV200-1450PQ43C312 
 
GOVERNOR
 
 

 
 

F 019 Z9E 670 
 
GOVERNOR
 
 
GOVERNOR

Isuzu 

9 420 612 520 
1157701572 
GOVERNOR
9 420 610 332 
1157701571 
GOVERNOR
9 420 610 332 
1157701573 
GOVERNOR
9 420 611 671 
NP-EP/RSV200-1300PQ44/311 
1157709860 
GOVERNOR
9 420 612 857 
NP-EP/RSV200-1450PQ43/301 
1157706810 
GOVERNOR

Mitsubishi 

9 420 610 283 
NP-EP/RSV200-1300PQ39/311 
ME730780 
GOVERNOR
Back to top