Information governor
BOSCH
9 420 611 669
9420611669
ZEXEL
105404-5430
1054045430

Rating:
Scheme ###:
1. | [1] | 154620-0200 | GOVERNOR HOUSING |
3. | [1] | 154620-3200 | GASKET |
4. | [1] | 154620-9300 | COVER |
5. | [3] | 020006-1640 | BLEEDER SCREW M6P1L16 4T |
6. | [1] | 154621-4300 | BLEEDER SCREW |
7. | [1] | 154621-4100 | PLAIN WASHER |
8. | [1] | 154620-7900 | ADAPTOR |
9. | [1] | 154375-9020 | PLATE |
10. | [5] | 029010-6810 | BLEEDER SCREW |
11. | [1] | 020106-1840 | BLEEDER SCREW M6P1L18 |
12. | [1] | 154013-6000 | FLAT-HEAD SCREW |
13. | [1] | 154011-0100 | HEXAGON NUT |
35. | [1] | 154500-0020 | GOVERNOR COVER |
38. | [1] | 154031-3000 | FLAT-HEAD SCREW |
39. | [1] | 139206-0600 | UNION NUT |
47. | [1] | 154036-0300 | CAPSULE |
51. | [2] | 139006-7100 | BLEEDER SCREW |
53. | [1] | 154010-0200 | FLAT-HEAD SCREW |
54. | [1] | 154011-4900 | UNION NUT |
56. | [4] | 020106-3840 | BLEEDER SCREW |
65. | [1] | 153020-5220 | STOPPING DEVICE |
66. | [1] | 026518-2240 | GASKET D21.9&18.2T1 |
80. | [1] | 154063-5100 | COVER |
81. | [1] | 154358-7200 | BRACKET |
82. | [1] | 020006-2040 | BLEEDER SCREW M6P1L20 4T |
83. | [1] | 020006-2040 | BLEEDER SCREW M6P1L20 4T |
84. | [1] | 020006-1640 | BLEEDER SCREW M6P1L16 4T |
86. | [1] | 020006-2040 | BLEEDER SCREW M6P1L20 4T |
100. | [1] | 154621-2420 | FLYWEIGHT ASSEMBLY |
102. | [1] | 029321-2020 | LOCKING WASHER |
103. | [1] | 029231-2030 | UNION NUT |
117. | [1] | 154123-0120 | SLIDING PIECE |
118/1. | [0] | 029311-0010 | SHIM D14&10.1T0.2 |
118/1. | [0] | 029311-0180 | SHIM D14&10.1T0.3 |
118/1. | [0] | 029311-0190 | SHIM D14&10.1T0.40 |
118/1. | [0] | 029311-0210 | SHIM D14&10.1T1 |
118/1. | [0] | 139410-0000 | SHIM D14.0&10.1T0.5 |
118/1. | [0] | 139410-0100 | SHIM D14.0&10.1T1.5 |
118/1. | [0] | 139410-3000 | SHIM D14&10.1T2.0 |
118/1. | [0] | 139410-3100 | SHIM D14&10.1T3.0 |
118/1. | [0] | 139410-3200 | SHIM D14&10.1T4.0 |
130. | [1] | 154150-0400 | GOVERNOR SPRING |
132. | [1] | 154154-4600 | COILED SPRING |
135. | [1] | 154158-1820 | HEADLESS SCREW |
136. | [1] | 154011-1700 | UNION NUT |
137. | [2] | 026512-1540 | GASKET D15.4&12.2T1.50 |
138. | [1] | 154159-1200 | CAP NUT |
140. | [1] | 154185-4120 | HEADLESS SCREW |
141. | [1] | 029201-6080 | UNION NUT |
150. | [1] | 154200-7020 | SWIVELLING LEVER |
151. | [1] | 154204-3000 | BUSHING |
152. | [2] | 029631-8020 | O-RING |
152. | [2] | 029631-8020 | O-RING |
153. | [2] | 016010-1640 | LOCKING WASHER |
153. | [2] | 016010-1640 | LOCKING WASHER |
154. | [1] | 139611-0000 | PACKING RING |
155. | [1] | 139411-0000 | SHIM |
156. | [0] | 029311-1070 | SHIM D16&11T0.5 |
157. | [1] | 154204-3100 | BUSHING |
159. | [1] | 025803-1310 | WOODRUFF KEY |
160. | [1] | 154206-2800 | BUSHING |
161. | [0] | 154206-0200 | PLAIN WASHER D19.5&11.2T1.0 |
170. | [1] | 154211-4420 | FORK LEVER |
174. | [1] | 154620-2520 | STRAP |
175. | [1] | 016010-0540 | LOCKING WASHER |
181. | [1] | 154236-4100 | TENSIONING LEVER |
182. | [1] | 154237-1100 | BEARING PIN |
190. | [1] | 154342-2320 | CONTROL LEVER |
236. | [1] | 154390-0000 | GASKET |
237. | [1] | 154390-0300 | GASKET |
238. | [1] | 029635-2020 | O-RING |
262. | [1] | 154062-5001 | BLEEDER SCREW |
263. | [1] | 014110-6440 | LOCKING WASHER |
331. | [1] | 154172-3520 | HEADLESS SCREW |
332. | [1] | 029201-6010 | UNION NUT |
335. | [2] | 026506-1040 | GASKET D9.9&6.2T1 |
336. | [1] | 154035-2800 | CAP NUT |
400. | [1] | 154620-8700 | CAPSULE |
401. | [1] | 154620-3100 | GASKET |
402. | [1] | 154620-8800 | BEARING PIN |
403. | [1] | 154620-8900 | PLATE |
404. | [1] | 010038-1840 | BLEEDER SCREW M8P1.25L18 |
405. | [1] | 154620-1500 | FLANGE BUSHING |
406. | [1] | 154620-4700 | BLEEDER SCREW |
407. | [2] | 014110-8440 | LOCKING WASHER |
407. | [2] | 014110-8440 | LOCKING WASHER |
408. | [2] | 014010-8140 | PLAIN WASHER D18&8.5T1.6 |
408. | [2] | 014010-8140 | PLAIN WASHER D18&8.5T1.6 |
409. | [1] | 154620-9000 | O-RING |
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
zz is the number of bytes in the message after this byte. zz does not include the checksum. This value will change depending on the data that is associated with the IID.Checksum Calculation
The checksum is an important part of the M5X message. By using the checksum, the integrity of the message is determined. The second to last byte of every IID is the checksum, which is followed by an ASCII carriage return ($0D). The checksum is a 2's complement value of the summation of all the data bytes in the message. The message is a good message if all the bytes and the checksum add to zero (0).The following message is an example.5000240400580082AE<cr>The checksum for this message is AE. Although the message is sent in ASCII, the checksum must be calculated by using the hexadecimal value.
Table 3
Byte     ASCII Value     Hexadecimal Value    
50     $35 $30     $50    
00     $30 $30     $00    
24     $32 $34     $24    
04     $30 $34     $04    
00     $30 $30     $00    
58     $35 $38     $58    
00     $30 $30     $00    
82     $38 $32     $82    
Total         $152    
Truncated to LSB         $52    
2's Compement     $41 $45     $AE    
Total         $100    
Truncated to LSB         $00    CCM Heartbeat
You should check the connection to the CCM before you log in to the CCM. You should also check the connection (heartbeat) to the CCM during normal operation from time to time. The recommended PID is $F0 $12. Use PID $F0 $12 to read the current Security Level at a regular interval as a heartbeat. If the CCM does not answer to the read request, then there is a problem with the connection. This PID will also monitor the Security Level, which may have been changed.Security Levels
Every PID has an associated security level (0, 1, 2, or 3) within the CCM. A user within a particular security level may use PID's in that level or lower levels. PID's cannot be accessed by the user in levels higher than the password allows. For example, a user at security level 2 can access level 2, 1, and 0, but not level 3.The answering modem will be hung up if the password is not entered (sets the security level) within one minute. Specifically, if DCD is held low by the PC, and the security level is at 0 for more than one minute, DTR will be toggled by the CCM (answering modem hung up). Also, if the RS-232C cable is disconnected for more than five seconds, DTR will be toggled, and the security level will be set to 0.When power is removed from the CCM, the security level will be changed to 2, if the CCM was operating at security level 3.The following chart defines the PID's within each security level
The checksum is an important part of the M5X message. By using the checksum, the integrity of the message is determined. The second to last byte of every IID is the checksum, which is followed by an ASCII carriage return ($0D). The checksum is a 2's complement value of the summation of all the data bytes in the message. The message is a good message if all the bytes and the checksum add to zero (0).The following message is an example.5000240400580082AE<cr>The checksum for this message is AE. Although the message is sent in ASCII, the checksum must be calculated by using the hexadecimal value.
Table 3
Byte     ASCII Value     Hexadecimal Value    
50     $35 $30     $50    
00     $30 $30     $00    
24     $32 $34     $24    
04     $30 $34     $04    
00     $30 $30     $00    
58     $35 $38     $58    
00     $30 $30     $00    
82     $38 $32     $82    
Total         $152    
Truncated to LSB         $52    
2's Compement     $41 $45     $AE    
Total         $100    
Truncated to LSB         $00    CCM Heartbeat
You should check the connection to the CCM before you log in to the CCM. You should also check the connection (heartbeat) to the CCM during normal operation from time to time. The recommended PID is $F0 $12. Use PID $F0 $12 to read the current Security Level at a regular interval as a heartbeat. If the CCM does not answer to the read request, then there is a problem with the connection. This PID will also monitor the Security Level, which may have been changed.Security Levels
Every PID has an associated security level (0, 1, 2, or 3) within the CCM. A user within a particular security level may use PID's in that level or lower levels. PID's cannot be accessed by the user in levels higher than the password allows. For example, a user at security level 2 can access level 2, 1, and 0, but not level 3.The answering modem will be hung up if the password is not entered (sets the security level) within one minute. Specifically, if DCD is held low by the PC, and the security level is at 0 for more than one minute, DTR will be toggled by the CCM (answering modem hung up). Also, if the RS-232C cable is disconnected for more than five seconds, DTR will be toggled, and the security level will be set to 0.When power is removed from the CCM, the security level will be changed to 2, if the CCM was operating at security level 3.The following chart defines the PID's within each security level