Information:

The results of the preceding procedure are in the following list:
The output corresponds to the desired pressure range. Stop.
The output does not correspond to the desired pressure range. Proceed to 3.
Calibrate the transducer. This assumes that the transducer is mounted on the engine.
Turn the isolation valve on the transducer mounting. This isolates the transducer from the engine. An arrow on the valve indicates the direction of flow. See illustration 2.
Apply a pressure that is equal to 4 mA to the transducer. See table 1. See the pressure port connection in illustration 2.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 4mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 20mA to the transducer. See table 1. See the pressure port connection in illustration 2.Note: The full range of pressure may not be available. Use partial pressure. Use the highest possible pressure. This will yield the best accuracy. See table 1.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 20mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 4mA to the transducer. Verify that the ammeter displays 4mA.The results of the preceding procedure are in the following list:
The output corresponds to the desired pressure range. The transducer is calibrated. Stop.
The output does not correspond to the desired pressure range. Proceed to 4.
Reapply the pressure.
Apply the pressure that is equal to 4mA to the transducer. See table 1. See the pressure port connection in illustration 2.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 4mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 20mA to the transducer. See table 1. See the pressure port connection in illustration 2.Note: The full range of pressure may not be available. Use partial pressure. Use the highest possible pressure. This will yield the best accuracy. See table 1.
Monitor the ammeter. Adjust the zero dial until the ammeter reads 20mA. See the location of the zero dial that is in illustration 1.
Apply the pressure that is equal to 4mA to the transducer. Verify that the ammeter displays 4mA.The results of the preceding procedure are in the following list:Note: Repeat the procedure several times in order to properly calibrate the transducer. Continue until the 4mA signal is correct and the 20mA signal is correct.
The output corresponds to the desired pressure range. The transducer is calibrated. Stop.
The output does not correspond to the desired pressure range. Replace the transducer. Verify that the repair resolves the problem. Stop.

Have questions with 105404-5291?





Group cross 105404-5291 ZEXEL

9 420 611 510 
NP-EP/RSV200-1450AQ2A302 
 
GOVERNOR
9 420 610 352 
NP-EP/RSV200-1450AQ2A302 
 
GOVERNOR
9 420 610 765 
 
GOVERNOR
9 420 610 766 
 
GOVERNOR
9 420 610 767 
 
GOVERNOR
9 420 614 513 
NP-EP/RSV200-1300AQ39A12 
 
GOVERNOR
9 420 610 768 
NP-EP/RSV200-1200AQ36A12 
 
GOVERNOR
9 420 610 353 
NP-EP/RSV200-1200AQ36A302 
 
GOVERNOR
9 420 610 769 
NP-EP/RSV200-1300AQ39A302 
 
GOVERNOR
9 420 610 354 
NP-EP/RSV200-1450AQ2A12 
 
GOVERNOR
9 420 610 770 
 
GOVERNOR
9 420 614 505 
NP-EP/RSV200-1300AQ39A12 
 
GOVERNOR
 
 
GOVERNOR
105404-5291  
 
 
GOVERNOR
9 420 611 661 
NP-EP/RSV200-1350AQ49A302 
 
GOVERNOR
Back to top