105404-5231 ZEXEL 9 420 614 513 BOSCH GOVERNOR 9420614513 1054045231


 

Information governor

BOSCH 9 420 614 513 9420614513
ZEXEL 105404-5231 1054045231
105404-5231 GOVERNOR
Rating:
51
Buy GOVERNOR 105404-5231 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 154620-0200 GOVERNOR HOUSING
2. [1] 154007-2900 CAPSULE
3. [1] 154620-3200 GASKET
4. [1] 154620-1401 COVER
5. [4] 020006-1640 BLEEDER SCREW M6P1L16 4T
6. [1] 154621-4300 BLEEDER SCREW
7. [1] 154621-4100 PLAIN WASHER
8. [1] 154620-7900 ADAPTOR
9. [1] 154375-9020 PLATE
10. [5] 029010-6810 BLEEDER SCREW
11. [1] 020106-1840 BLEEDER SCREW M6P1L18
12. [1] 154010-0100 FLAT-HEAD SCREW
13. [2] 154011-0100 HEXAGON NUT
13. [2] 154011-0100 HEXAGON NUT
16. [1] 029632-5070 O-RING
35. [1] 154500-0020 GOVERNOR COVER
38. [1] 154031-3000 FLAT-HEAD SCREW
39. [1] 139206-0600 UNION NUT
47. [1] 154036-0300 CAPSULE
51. [2] 139006-7100 BLEEDER SCREW
53. [1] 154010-0200 FLAT-HEAD SCREW
56. [4] 020106-3840 BLEEDER SCREW
65. [1] 155404-5120 STOPPING DEVICE
66. [1] 026518-2240 GASKET D21.9&18.2T1
80. [1] 154063-5100 COVER
81. [1] 154358-7200 BRACKET
82. [1] 029020-6260 BLEEDER SCREW
83. [1] 029020-6260 BLEEDER SCREW
84. [1] 020006-1640 BLEEDER SCREW M6P1L16 4T
86. [1] 020006-2040 BLEEDER SCREW M6P1L20 4T
100. [1] 154621-2120 FLYWEIGHT ASSEMBLY
102. [1] 029321-2020 LOCKING WASHER
103. [1] 029231-2030 UNION NUT
117. [1] 154123-0120 SLIDING PIECE
118/1. [0] 029311-0010 SHIM D14&10.1T0.2
118/1. [0] 029311-0180 SHIM D14&10.1T0.3
118/1. [0] 029311-0190 SHIM D14&10.1T0.40
118/1. [0] 029311-0210 SHIM D14&10.1T1
118/1. [0] 139410-0000 SHIM D14.0&10.1T0.5
118/1. [0] 139410-0100 SHIM D14.0&10.1T1.5
118/1. [0] 139410-3000 SHIM D14&10.1T2.0
118/1. [0] 139410-3100 SHIM D14&10.1T3.0
118/1. [0] 139410-3200 SHIM D14&10.1T4.0
130. [1] 154150-0400 GOVERNOR SPRING
132. [1] 154154-5200 COILED SPRING
135. [1] 154158-5120 HEADLESS SCREW
136. [1] 154011-1700 UNION NUT
137. [2] 026512-1540 GASKET D15.4&12.2T1.50
138. [1] 154159-1200 CAP NUT
140. [1] 154177-1020 HEADLESS SCREW
141. [1] 029201-6010 UNION NUT
150. [1] 154200-7020 SWIVELLING LEVER
151. [1] 154204-4300 BUSHING
152. [2] 029631-8020 O-RING
152. [2] 029631-8020 O-RING
153. [2] 016010-1640 LOCKING WASHER
153. [2] 016010-1640 LOCKING WASHER
154. [1] 139611-0000 PACKING RING
155. [1] 139411-0000 SHIM
156. [0] 029311-1070 SHIM D16&11T0.5
157. [1] 154204-4400 BUSHING
159. [1] 025803-1310 WOODRUFF KEY
160. [1] 154206-2800 BUSHING
161. [0] 154206-0200 PLAIN WASHER D19.5&11.2T1.0
170. [1] 154211-4420 FORK LEVER
174. [1] 154620-2520 STRAP
175. [1] 016010-0540 LOCKING WASHER
181. [1] 154236-4100 TENSIONING LEVER
182. [1] 154237-1100 BEARING PIN
190. [1] 154395-8620 CONTROL LEVER
236. [1] 154390-0000 GASKET
237. [1] 154390-0300 GASKET
238. [1] 029635-2020 O-RING
335. [2] 026506-1040 GASKET D9.9&6.2T1
336. [1] 154035-1600 CAP NUT
400. [1] 154620-8700 CAPSULE
401. [1] 154620-3100 GASKET
402. [1] 154620-8800 BEARING PIN
403. [1] 154620-8901 PLATE
404. [1] 010038-1840 BLEEDER SCREW M8P1.25L18
405. [1] 154620-1500 FLANGE BUSHING
406. [1] 154620-4700 BLEEDER SCREW
407. [2] 014110-8440 LOCKING WASHER
407. [2] 014110-8440 LOCKING WASHER
408. [2] 014010-8140 PLAIN WASHER D18&8.5T1.6
408. [2] 014010-8140 PLAIN WASHER D18&8.5T1.6
409. [1] 154620-9000 O-RING

Include in #1:

101609-3312 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105404-5231 
9 420 614 513 
NP-EP/RSV200-1300AQ39A12 
   
GOVERNOR
K 14JB MECHANICAL GOVERNOR GOV RSV GOV




Information:

Test Procedure
System Operation
The SLC 5/04 diagnostic indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: Input devices, Output devices, Wiring and The controller.The green "DH+" LED is flashing. There are no active nodes on the network.The red "DH+" LED is flashing. There are duplicate active nodes on the link with the same address.The red "FLT" LED is flashing during operation. The processor detects a major fault. The fault is in the processor expansion chassis or the fault is in the memory.
Illustration 1 g00563551
Diagram of the LED indicators
Illustration 2 g00562937
Functional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Check the communication parameters of the customer supplied devices.
Check the communication parameter of the programmer.The results of the preceding procedure are in the following list:
The programmer address and the processor address are different. Proceed to 3.
The programmer address and the processor address are not different. Set the addresses. Verify that the repair resolves the problem. Stop.
Change the baud rate.
Change the baud rate of the programmer and change the baud rate of the processor.
Increase the maximum node address.Note: The default baud rate is 57,600. The default node address is one.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 4.
Check line voltage.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.

Have questions with 105404-5231?





Group cross 105404-5231 ZEXEL

9 420 611 510 
NP-EP/RSV200-1450AQ2A302 
 
GOVERNOR
9 420 610 352 
NP-EP/RSV200-1450AQ2A302 
 
GOVERNOR
9 420 610 765 
 
GOVERNOR
9 420 610 766 
 
GOVERNOR
9 420 610 767 
 
GOVERNOR
105404-5231  
9 420 614 513 
NP-EP/RSV200-1300AQ39A12 
 
GOVERNOR
9 420 610 768 
NP-EP/RSV200-1200AQ36A12 
 
GOVERNOR
9 420 610 353 
NP-EP/RSV200-1200AQ36A302 
 
GOVERNOR
9 420 610 769 
NP-EP/RSV200-1300AQ39A302 
 
GOVERNOR
9 420 610 354 
NP-EP/RSV200-1450AQ2A12 
 
GOVERNOR
9 420 610 770 
 
GOVERNOR
9 420 614 505 
NP-EP/RSV200-1300AQ39A12 
 
GOVERNOR
 
 
GOVERNOR
 
 
GOVERNOR
9 420 611 661 
NP-EP/RSV200-1350AQ49A302 
 
GOVERNOR
Back to top