105400-5890 ZEXEL F 019 Z1E 527 BOSCH GOVERNOR f019z1e527 1054005890


 

Information governor

BOSCH F 019 Z1E 527 f019z1e527
ZEXEL 105400-5890 1054005890
105400-5890 GOVERNOR
Rating:
16
Buy GOVERNOR 105400-5890 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 154000-6300 GOVERNOR HOUSING
3. [1] 029632-5070 O-RING
4. [1] 154007-2900 CAPSULE
6. [1] 154007-0200 ADAPTOR
7. [1] 020018-1840 BLEEDER SCREW M8P1.25L18
9. [1] 154350-1900 PLATE
10. [6] 029010-6810 BLEEDER SCREW
12. [1] 154010-1200 FLAT-HEAD SCREW
13. [2] 154011-0100 HEXAGON NUT
13. [2] 154011-0100 HEXAGON NUT
35. [1] 154500-1020 GOVERNOR COVER
35/2. [1] 154321-0400 BUSHING
38. [1] 154031-2400 FLAT-HEAD SCREW
39. [1] 139206-0600 UNION NUT
47. [2] 154036-0300 CAPSULE
47. [2] 154036-0300 CAPSULE
51. [2] 020106-5040 BLEEDER SCREW
53. [1] 154010-1100 FLAT-HEAD SCREW
56. [4] 020106-3840 BLEEDER SCREW
65. [1] 154050-6120 STOPPING DEVICE
80. [1] 154063-1400 COVER
82. [2] 029020-6210 BLEEDER SCREW
83. [2] 020006-1640 BLEEDER SCREW M6P1L16 4T
100. [1] 154101-0320 FLYWEIGHT ASSEMBLY
101. [1] 025803-1610 WOODRUFF KEY
102. [1] 029321-2020 LOCKING WASHER
103. [1] 029231-2030 UNION NUT
117. [1] 154123-2320 SLIDING PIECE
118/1. [0] 029311-0010 SHIM D14&10.1T0.2
118/1. [0] 029311-0180 SHIM D14&10.1T0.3
118/1. [0] 029311-0190 SHIM D14&10.1T0.40
118/1. [0] 029311-0210 SHIM D14&10.1T1
118/1. [0] 139410-0000 SHIM D14.0&10.1T0.5
118/1. [0] 139410-0100 SHIM D14.0&10.1T1.5
118/1. [0] 139410-3000 SHIM D14&10.1T2.0
118/1. [0] 139410-3100 SHIM D14&10.1T3.0
118/1. [0] 139410-3200 SHIM D14&10.1T4.0
130. [1] 154150-6400 GOVERNOR SPRING
132. [1] 154154-1200 COILED SPRING
135. [1] 154158-1020 HEADLESS SCREW
136. [1] 154011-1700 UNION NUT
137. [2] 026512-1540 GASKET D15.4&12.2T1.50
138. [1] 154159-1200 CAP NUT
140. [1] 154177-0920 HEADLESS SCREW
141. [1] 029201-6010 UNION NUT
150. [1] 154200-7020 SWIVELLING LEVER
151. [1] 154204-3000 BUSHING
152. [2] 029631-8020 O-RING
152. [2] 029631-8020 O-RING
153. [2] 016010-1640 LOCKING WASHER
153. [2] 016010-1640 LOCKING WASHER
154. [1] 139611-0000 PACKING RING
155. [1] 139411-0000 SHIM
156. [0] 029311-1090 SHIM D16&11T0.3
157. [1] 154204-3100 BUSHING
159. [1] 025803-1310 WOODRUFF KEY
160. [1] 154206-2800 BUSHING
161. [0] 154206-0200 PLAIN WASHER D19.5&11.2T1.0
170. [1] 154210-7320 FORK LEVER
174. [1] 154230-3920 STRAP
175. [1] 016010-0540 LOCKING WASHER
181. [1] 154236-4100 TENSIONING LEVER
182. [1] 154237-0100 BEARING PIN
190. [1] 154349-2220 CONTROL LEVER
191. [1] 154380-0320 CONTROL LEVER
192. [1] 020006-4040 BLEEDER SCREW
201. [1] 029631-0030 O-RING &9.8W2.3
203. [1] 154322-0100 CAP
207. [1] 154326-5020 CONTROL LEVER
208. [1] 154327-7600 COILED SPRING
211/1. [0] 029311-0520 SHIM D20.8&10.3T0.2
211/1. [0] 029311-0530 SHIM D20.8&10.3T0.25
211/1. [0] 029311-0540 SHIM D20.8&10.3T0.3
211/1. [0] 029311-0550 SHIM D20.8&10.3T0.35
211/1. [0] 029311-0560 SHIM D20.8&10.3T0.4
211/1. [0] 029311-0570 SHIM D20.8&10.3T0.5
236. [1] 154390-0000 GASKET
237. [1] 154390-0300 GASKET
238. [1] 029635-2020 O-RING
335. [2] 026506-1040 GASKET D9.9&6.2T1
336. [1] 154035-1600 CAP NUT

Include in #1:

101402-9240 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105400-5890 
105400-5891 
F 019 Z1E 527 
   
GOVERNOR
* K




Information:


8T0900 AC/DC Clamp-On AmmeterThe 8T0900 AC/DC Clamp-On Ammeter is a completely portable, self-contained instrument that allows electrical current measurements to be made without breaking the circuit or disturbing the insulation on conductors. A digital display is located on the ammeter for reading current directly in a range from 1 to 1200 amperes. If a optional 6V6014 Cable is connected between this ammeter and one of the digital multimeters, current readings of less than 1 ammeter can then be read directly from the display of the multimeter.A lever is used to open the jaws over the conductor [up to a diameter of 19 mm (.75 in)], and the spring loaded jaws are then closed around the conductor for current measurement. A trigger switch that can be locked in the ON or OFF position is used to turn on the ammeter. When the turn-on trigger is released, the last current reading is held on the display for 5 seconds. This allows accurate measurements to be taken in limited access areas where the digital display is not visible to the operator. A zero control is provided for DC operation, and power for the ammeter is supplied by batteries located inside the handle. Make reference to Special Instruction, Form No. SEHS8420 for more complete information for use of the 8T0900 Clamp-On Ammeter.
6V7070 Heavy-Duty Digital MultimeterThe 6V7070 Heavy-Duty Digital Multimeter is a completely portable, hand held instrument with a digital display. This multimeter is built with extra protection against damage in field applications, and is equipped with seven functions and 29 ranges. The 6V7070 Multimeter has an instant ohms indicator that permits continuity checking for fast circuit inspection. It also can be used for troubleshooting small value capacitors.The 6V7800 Regular-duty Digital Multimeter (a low cost option to the Heavy-Duty Multimeter) is also available; however, the 6V7800 Multimeter does not have the 10A range or the instant ohms feature of the 6V7070 Multimeter. Make reference to Special Instruction, Form No. SEHS7734 for more complete information for use of the 6V7070 and 6V7800 Multimeters.Battery
Never disconnect any charging unit circuit or battery circuit cable from battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 6V4930 Battery Load Tester, the 8T900 Clamp-On Ammeter and the 6V7070 Multimeter to load test a battery that does not hold a charge when in

Have questions with 105400-5890?





Group cross 105400-5890 ZEXEL

F 019 Z1F 987 
NP-EP/RSV200-1600AQ21A302 
 
GOVERNOR
F 019 Z1F 988 
NP-EP/RSV200-1600AQ21A302 
 
GOVERNOR
 
 

 
 

 
 

 
 

 
 

F 019 Z1E 526 
 
GOVERNOR

Isuzu 

 
8943666760 
GOVERNOR
9 420 612 500 
NP-EP/RSV200-1600AQ21A312 
8943666751 
GOVERNOR
105400-5890  

105400-5891 
F 019 Z1E 527 
 
GOVERNOR
9 420 612 756 
NP-EP/RSV200-1350AQ49A312 
 
GOVERNOR
Back to top