Information fuel-injection pump
BOSCH
9 410 613 247
9410613247
ZEXEL
106067-8180
1060678180

Rating:
Scheme ###:
1. | [1] | 134000-8420 | PUMP HOUSING |
1/30. | [3] | 029040-6020 | STUD |
1/45. | [1] | 134311-0000 | SPACER RING |
1/50. | [12] | 029041-2100 | STUD |
5. | [6] | 134130-9320 | PLUNGER-AND-BARREL ASSY |
5/2. | [1] | 029331-9040 | GASKET |
5/3. | [1] | 134101-2920 | PLUNGER-AND-BARREL ASSY |
5/4. | [1] | 134563-0600 | BEARING PIN |
5/5. | [1] | 134110-7220 | DELIVERY-VALVE ASSEMBLY |
5/6. | [1] | 134116-1400 | FITTING |
5/7. | [1] | 029632-5080 | O-RING |
5/8. | [1] | 134117-0500 | FILLER PIECE |
5/9. | [1] | 134112-0200 | COILED SPRING |
5/10. | [1] | 134115-0100 | GASKET |
5/11. | [1] | 029632-9040 | O-RING |
5/12. | [1] | 029632-9040 | O-RING |
17/1. | [0] | 134139-2400 | SHIM T0.15 |
17/1. | [0] | 134139-2500 | SHIM T0.4 |
17/1. | [0] | 134139-2600 | SHIM T0.5 |
17/1. | [0] | 134139-2700 | SHIM T0.6 |
17/1. | [0] | 134139-2800 | SHIM T0.7 |
17/1. | [0] | 134139-2900 | SHIM T0.8 |
17/1. | [0] | 134139-3000 | SHIM T0.9 |
17/1. | [0] | 134139-3100 | SHIM T1.0 |
18. | [12] | 029301-2330 | PLAIN WASHER |
19. | [12] | 014111-2440 | LOCKING WASHER D21.5&12.2T3 |
20. | [12] | 013021-2140 | UNION NUT M12P1.75H10 |
21. | [1] | 134256-2000 | CONTROL RACK |
22. | [1] | 134226-0000 | FLAT-HEAD SCREW |
23. | [1] | 134510-3900 | GASKET |
24. | [1] | 134222-0100 | BUSHING |
25. | [6] | 134215-0100 | COMPRESSION SPRING |
26. | [6] | 134217-0200 | SLOTTED WASHER |
27. | [6] | 134200-0120 | TAPPET |
27/2. | [1] | 134203-0100 | BEARING PIN |
27/3. | [1] | 134204-0000 | ROLLER |
27/4. | [1] | 134205-0000 | BUSHING |
27/5. | [1] | 134213-0000 | BEARING PIN |
28. | [6] | 134140-0400 | SPRING SEAT D14T3.9 |
30. | [1] | 016650-2230 | BEARING PLATE |
34/1. | [0] | 134303-0000 | SHIM D59.8&43T1.2 |
34/1. | [0] | 134303-0100 | SHIM D59.8&43T1.5 |
34/1. | [0] | 134303-0200 | SHIM D59.8&43T1.8 |
34/1. | [0] | 134303-0300 | SHIM D59.8&43T2.0 |
34/1. | [0] | 134303-0400 | SHIM D59.8&43T0.6 |
35. | [4] | 029050-6360 | FLAT-HEAD SCREW |
36. | [1] | 134371-0100 | CAMSHAFT |
37. | [1] | 134305-0000 | BEARING SHELL |
38. | [2] | 029020-6140 | HEX-SOCKET-HEAD CAP SCREW |
39. | [2] | 134510-3900 | GASKET |
40. | [1] | 016650-2230 | BEARING PLATE |
41. | [1] | 134316-0200 | COVER |
42. | [1] | 026712-5020 | PACKING RING |
43/1. | [0] | 134314-0000 | SHIM T0.1 |
43/1. | [0] | 134314-0100 | SHIM T0.12 |
43/1. | [0] | 134314-0200 | SHIM T0.14 |
43/1. | [0] | 134314-0300 | SHIM T0.16 |
43/1. | [0] | 134314-0400 | SHIM T0.18 |
43/1. | [0] | 134314-0500 | SHIM T0.3 |
43/1. | [0] | 134314-0600 | SHIM T0.5 |
44. | [1] | 029635-5050 | O-RING |
50. | [3] | 139206-0400 | UNION NUT |
52. | [1] | 025805-1910 | WOODRUFF KEY |
53. | [1] | 014111-8410 | LOCKING WASHER |
54. | [1] | 139218-0000 | UNION NUT |
56. | [1] | 134416-1500 | COVER |
57. | [2] | 014530-6540 | TAB WASHER |
58. | [2] | 021306-3940 | FLAT-HEAD SCREW |
67. | [1] | 029111-4050 | CAPSULE |
68. | [1] | 029341-4130 | GASKET D20&13.8T2* |
75. | [1] | 029731-4080 | EYE BOLT |
76. | [2] | 029341-4130 | GASKET D20&13.8T2* |
82. | [1] | 134420-0020 | BLEEDER SCREW |
84. | [1] | 026514-1840 | GASKET D17.9&14.2T1 |
96. | [1] | 029639-0030 | O-RING |
121. | [1] | 029633-1020 | O-RING |
124. | [4] | 029320-6010 | LOCKING WASHER |
125. | [4] | 029300-6170 | SHIM D12&6.2T1 |
126. | [4] | 029340-6120 | GASKET |
138. | [1] | 029731-4080 | EYE BOLT |
139. | [2] | 029341-4130 | GASKET D20&13.8T2* |
140. | [1] | 134433-1720 | PIPE |
141. | [1] | 029731-4080 | EYE BOLT |
142. | [2] | 029341-4130 | GASKET D20&13.8T2* |
144. | [2] | 014110-8440 | LOCKING WASHER |
145. | [2] | 010038-2040 | BLEEDER SCREW M8P1.25L20 |
Include in #1:
106672-4580
as FUEL INJECTION PUMP
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Torque for Standard Bolts, Nuts and Taperlock Studs
The following charts give general torques for bolts, nuts and taperlock studs of SAE Grade 5 or better quality.
Torques for Bolts and Nuts With Standard Threads
Torques for Taperlock Studs
Use these standard torque values for all fasteners unless otherwise specified in this publication or in the Service Manual.Torque for Metric Fasteners
This product uses 10.9 Grade metric fasteners.
Be very careful never to mix metric with customary (standard) fasteners. Mismatched or incorrect fasteners will cause engine damage or malfunction and may even result in personal injury.Original fasteners removed from the engine should be saved for reassembly whenever possible. If new fasteners are needed, they must be of the same size and grade as the ones that are being replaced.The material strength identification is usually shown on the bolt head by numbers (8.8, 10.9, etc.). Use these standard torque values unless otherwise specified in this publication or the Service Manual.The following charts give general torques for bolts and nuts with Metric Threads of SAE Grade 8.8 or better quality.
Torques for Bolts and Nuts with Metric Threads
Torque for Standard Hose Clamps-Worm Drive Band Type
The following chart gives the torques for initial installation of hose clamps on new hose and for reassembly or tightening of hose clamps on existing hose.
Torque for Constant Torque Hose Clamps
A constant torque hose clamp can be used in place of any standard hose clamp. Make sure the constant torque hose clamp is the same size as the standard clamp. Due to extreme temperature changes, hose will heat set. Heat setting causes hose clamps to loosen. Loose hose clamps can result in leaks. There have been reports of component failures caused by hose clamps loosening. The new, constant torque hose clamp will help prevent these failures.Each installation application can be different depending on the type of hose, fitting material and anticipated expansion or contraction of the hose and fittings. A torque wrench should be used for proper installation of the new, constant torque hose clamps. Constant torque hose clamps should be installed as follows:* To allow for maximum expansion, install clamps at 50 lb in (5.7 N m).* To allow for equal expansion and contraction, install clamps at 90 lb in (10.2 N m).* To allow for maximum contraction, install clamps at 125 lb in (14.1 N m).
The following charts give general torques for bolts, nuts and taperlock studs of SAE Grade 5 or better quality.
Torques for Bolts and Nuts With Standard Threads
Torques for Taperlock Studs
Use these standard torque values for all fasteners unless otherwise specified in this publication or in the Service Manual.Torque for Metric Fasteners
This product uses 10.9 Grade metric fasteners.
Be very careful never to mix metric with customary (standard) fasteners. Mismatched or incorrect fasteners will cause engine damage or malfunction and may even result in personal injury.Original fasteners removed from the engine should be saved for reassembly whenever possible. If new fasteners are needed, they must be of the same size and grade as the ones that are being replaced.The material strength identification is usually shown on the bolt head by numbers (8.8, 10.9, etc.). Use these standard torque values unless otherwise specified in this publication or the Service Manual.The following charts give general torques for bolts and nuts with Metric Threads of SAE Grade 8.8 or better quality.
Torques for Bolts and Nuts with Metric Threads
Torque for Standard Hose Clamps-Worm Drive Band Type
The following chart gives the torques for initial installation of hose clamps on new hose and for reassembly or tightening of hose clamps on existing hose.
Torque for Constant Torque Hose Clamps
A constant torque hose clamp can be used in place of any standard hose clamp. Make sure the constant torque hose clamp is the same size as the standard clamp. Due to extreme temperature changes, hose will heat set. Heat setting causes hose clamps to loosen. Loose hose clamps can result in leaks. There have been reports of component failures caused by hose clamps loosening. The new, constant torque hose clamp will help prevent these failures.Each installation application can be different depending on the type of hose, fitting material and anticipated expansion or contraction of the hose and fittings. A torque wrench should be used for proper installation of the new, constant torque hose clamps. Constant torque hose clamps should be installed as follows:* To allow for maximum expansion, install clamps at 50 lb in (5.7 N m).* To allow for equal expansion and contraction, install clamps at 90 lb in (10.2 N m).* To allow for maximum contraction, install clamps at 125 lb in (14.1 N m).